FCS SpillSens Digital Float Sensor Instruction Manual

July 23, 2024
FCS

FCS SpillSens Digital Float Sensor

Product Information

Specifications

  • Product Name: SpillSens Digital Float Sensor
  • Alert Levels: Green, Amber, Red
  • Certifications: ATEX (Zone 0)
  • Features: Intrinsically safe, no moving parts, compatible with various loggers
  • Battery Life: Five years with ATEX Battery Pack

Product Usage Instructions

Installation

  1. Install the SpillSens sensor at a critical height in a chamber.
  2. Ensure the sensor is properly connected to a data logger.

Alert Levels

  • Green: Normal conditions
  • Amber: Rising levels
  • Red: Critical levels reached

Monitoring

  1. Access the dedicated online portal, SpillGuard, for monitoring and fleet management.
  2. Utilize the graphical map view on SpillGuard to monitor the status of each installation.

INTRODUCTION

The multi-alarm digital float sensor delivers early warnings of small sewer and customer-side blockages and overflows

  • Installed at a critical height in a chamber, SpillSens uses digital positioning technology to monitor sewer levels constantly and effectively.
  • Programmed with three alert levels, SpillSens indicates green when conditions are normal, amber when levels are rising, and red when critical levels are reached.
  • Ideal for Incident Prevention Monitoring, SpillSens supports compliance with Outcome Delivery Incentives and helps to protect the environment by reducing pollution incidents.
  • ATEX (Zone 0) certified, SpillSens is dependable and, when paired with our ATEX Battery Pack, can deliver accelerated sample rates and increased dial-in frequency whilst maintaining a five-year battery life.

Key Features and Benefits

  • three levels of alert (green, amber and red), based on the angle of the sensor
  • designed to have no moving parts, unlike traditional steel ball and micro-switch sensors
  • intrinsically safe; ATEX-certified for use in Zone 0 hazardous areas
  • dedicated online portal (SpillGuard) for monitoring and fleet management
  • highly compatible; works in conjunction with IS Log and other FCS loggers

SpillGuard

The secure online portal for the dedicated monitoring and fleet management of the SpillSens multi-level alert system.

Designed specifically for use with SpillSens, SpillGuard provides secure access to the generated data for effective fleet management and network monitoring.

Using Google Maps, SpillGuard provides a detailed map interface that color codes the status of each installation. The three alert levels (green, amber, and red) can be supplemented with user-assigned statuses, such as “site under investigation” or “alert cleared”.

SpillGuard can display general site statistics and trends, as well as specific site details. Individual users and reports are managed using an advanced platform which includes the option to forward alarm messages via e-mail or SMS.

INSTALLATION

SpillSens is an easy-to-install, low-maintenance digital float sensor that delivers early warnings of small sewer and customer-side blockages and overflows. Each SpillSens sensor is connected to a data logger. When the tilt level reaches a specified angle, the logger uses NBIoT cellular telemetry to transmit alert messages to SpillGuard, our bespoke web portal for SpillSens

SpillSens

Digital Float Sensor

  • Intrinsically safe
  • Three alert levels
  • No moving components Compatible with multiple loggers

IS Log

TEX Certified Data Logger

  • NBIoT cellular telemetry
  • Multi-application compatibility Intrinsically safe
  • Wireless programming
  • Easy software integration

SpillGuard

Online Data Portal

  • Real-time alerts Three alert levels Graphical map view Detailed site view Data security features

We are experienced and respected manufacturers of monitoring and telemetry equipment for water and wastewater networks , together with telemetry AMR and facilities optimization products.

Clean Water Network Monitoring
With over 30 years in the water industry, FCS is skilled at addressing the challenges of water network monitoring. With increased pressure on water globally, we can solve the problems of effective water network management, providing data on performance and enabling effective network management.

Waste Water Network Monitoring
Control of waste water networks is a key public health challenge. Effective monitoring of waste water networks reduces both frequency and impact of pollution events. Permanent installation of remote monitoring equipment helps to alert network operators to immediate problem sites.

Automated Meter Reading
Accurate and consistent data is the foundation for effectively controlling energy usage and reducing waste. AMR delivers precise and timely consumption data for investigation and analysis of energy usage as well as exact billing.

Facilities Management
FCS has pioneered the development of wireless monitoring solutions for fixed network deployment. These can be combined with a variety of sensors, providing our partners with ‘near real-time’ data that they need to help their customers to eliminate waste, cut costs and reduce carbon emissions.

Fluid Conservation Systems

1960 Old Gatesburg Road, Ste #150, State College, PA 16803
United States
Tel: +1 800 531 5465
Email: sales@fluidconservation.com Web: www.fluidconservation.com

FAQ

Q: How long is the battery life of SpillSens?

A: With the ATEX Battery Pack, SpillSens can maintain a battery life of up to five years.

Q: What are the alert levels provided by SpillSens?

A: SpillSens offers three alert levels – green for normal conditions, amber for rising levels, and red for critical levels.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals