The product is a luminaire that requires installation and operation in compliance with national safety regulations. It should only be installed and commissioned by a qualified electrician. The manufacturer does not accept liability for damage caused by improper use or installation. The luminaire has electronic components that are protected against overvoltage according to DIN EN 61547. Additional overvoltage protection components are recommended for extra protection against transients.
The luminaire is available in two models: 51 130 K27 and 51 130 K3. The specifications for both models include:
- Lamp Module connected wattage: 26.4 W
- Luminaire connected wattage: 30 W
- Rated temperature: ta max = 25°C
- Ambient temperature: ta max = 50°C
- Colour temperature: 2700 K (K27) or 3000 K (K3)
- Colour rendering index (CRI): > 90
- Module luminous flux: 3845 lm (K27) or 3970 lm (K3)
- Luminaire luminous flux: 2558 lm (K27) or 2642 lm (K3)
- Luminaire luminous efficiency: 85.3 lm/W (K27) or 88.1 lm/W (K3)
Product Usage Instructions
- Position the glass over the luminaire fitting, ensuring that the retaining spring fits into the recess in the raised edge of the glass.
- Press the glass against the retaining spring at a flat angle, pushing it into the luminaire fitting.
- Apply gentle pressure on the glass to fix it in place through the two lobes on the opposite side.
- Screw the grub screw (hexagon socket head wrench size 2.5) against the retaining spring to securely hold the glass in place and make it resistant to vibration.
- If you need to change the orientation of the rotatable luminaire glass, loosen the grub screw before adjusting the glass. After adjusting, screw the grub screw against the retaining spring with gentle pressure.
- To open the luminaire, unscrew the grub screw (Allen screw) of the glass retaining spring until it is fully unscrewed. Press the luminaire glass against the spring pressure to release it from the luminaire fitting.
- If you need to replace the LED unit, disconnect the system and open the luminaire. The designation of the LED unit can be found on a label inside. The replacement LED unit should have the same light color and light output as the original. Qualified persons can replace the LED unit using standard tools. Close the luminaire after replacement. If the glass is damaged, it must be replaced.
Wall luminaire for indoor use
Instructions for use
Application
Closed and unshielded wall luminaire · Indoor luminaire made of hand-blown
opal glass, satin matt and with metal fitting.
Due to the soft and flowing shape of the glass, you can create seemingly
random wall arrangements with other luminaires in this series.
The luminaire glass can be rotated on the fitting.
Product description
-
Metal luminaire mounting plate, finish Colour white
-
Lichtbaustein® · PEBBLES · Type A
-
Hand-blown opal glass, satin matt
-
2 mounting holes ø 5.5 mm
-
Distance apart 230 mm
-
2 cable entries for through-wiring for connection cable up to ø 10,5 mm max. 5 x 1.5@
-
Connection terminal 2.5@
-
Earth conductor connection
-
LED power supply unit 220-240 V x 0/50-60 Hz
-
DALI-controllable
-
Number of DALI addresses: 0
-
Basic insulation is provided between the mains and control cables
-
BEGA Thermal Control®
-
Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire
-
Safety class I
Impact strength IK04 -
Protection against mechanical
-
impacts < 0.5 joule
-
c – Conformity mark
-
Weight: 3.7 kg
-
This product contains light sources of energy efficiency class(es) D, E
Safety
The installation and operation of this luminaire are subject to national
safety regulations. Installation and commissioning may only be carried out by
a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or
installation. If subsequent modifications are made to the luminaire, the
person responsible for these modifications shall be considered the
manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we
recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.
Lamp
- Module connected wattage 26.4 W
- Luminaire connected wattage 30 W
- Rated temperature ta = 25 °C
- Ambient temperature ta max = 50 °C
51 130 K27
- Colour temperature 2700 K
- Colour rendering index CRI > 90
- Module luminous flux 3845 lm
- Luminaire luminous flux 2558 lm
- Luminaire luminous efficiency 85,3 lm / W
51 130 K3
- Colour temperature 3000 K
- Colour rendering index CRI > 90
- Module luminous flux 3970 lm
- Luminaire luminous flux 2642 lm
- Luminaire luminous efficiency 88,1 lm / W
Installation
LED are high-quality electronic components! Please avoid touching the light
output opening of the LED directly during installation or relamping.
Lead the mains supply cable through the cable entry into the luminaire
housing.
Secure the luminaire fitting to the installation surface with the fixing
materials provided or other suitable materials.
Be sure to use the gasket rings supplied. Establish earth conductor connection
and make the electrical connection to the terminals. For digital control
please use the connecting terminal DA, DA.
In case this terminal is not used the luminaire will be operated at full light
output.
Position the glass over the luminaire fitting so that the retaining spring
fits into the recess in the raised edge of the glass.
Press the glass against the retaining spring at a flat angle as far as it will
go and push it into the luminaire fitting (see drawing).
Gentle pressure on the glass will fix it in the luminaire fitting through the
two lobes on the opposite side.
IMPORTANT: Screw the grub screw (hexagon socket head wrench size 2,5)
with gentle pressure against the retaining spring.
In this way, the glass is held securely in place and is resistant to
vibration. If the orientation of the rotatable luminaire glass on the fitting
is to be changed, the grub screw must be loosened. After adjusting the glass,
screw the grub screw with gentle pressure against the retaining spring.
Opening the luminaire
Unscrew the grub screw (Allen screw) of the glass retaining spring of the
luminaire fitting as far as it will go.
The luminaire glass must be pressed against the spring pressure of the glass
retaining spring in order to release it from the luminaire fitting.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt.
Defective glass must be replaced.
Replacement of the LED unit
The designation of the LED unit is noted on a label in the luminaire.
The light colour and light output of BEGA replacement units correspond to
those of the LED units originally fitted. The LED unit can be replaced by
qualified persons using standard tools.
Disconnect the system and open the luminaire. Replace the LED unit.
Close the luminaire.
A damaged glass must be replaced.
Spares
- Spare glass 11 003 615 .0R G
- LED spare assembly unit 2700 K 75 005 453 K27
- LED spare assembly unit 3000 K 75 005 453 K3