AMBIANCE Intrigue 42 Fireplaces - Dimension

BTU EFFICIENCY VENTING GLASS
Max NG Max PG Min NG Min PG
State** Type Max. Height In & Out Diameter
Dimensions Area sq in
39,500 39,500 18,500 18,500
Pure vision Robax 26” x 35” 910
DIMENSIONS MINIMUM FRAMING DIMENSIONS BLOWING **MANTEL

SHELF CLEARANCES
---|---|---|---
Height| Depth| Width| Height| Depth| Width| Type| PCM| 9-inch shelf**
34.5”| 20”| 40.875”| 44.5”| 20”| 41.875”| Variable speed| 150| 12.5’’

Framing and Clearances

AMBIANCE Intrigue 42 Fireplaces - framing dimensions

CLEARANCES

Top of unit face to header (cement board may be used in this area).| 10’’ (254mm)
From unit left & right sides and back| 1/2’’ (13mm)
To flooring| 0’’ (0mm)
Unit top to ceiling| 31’’ (787mm)
Side of unit face to adjacent sidewall| 3’’ (76mm)
Mantel 9’’ (229mm) deep from top of fireplace| 12-1/2’’ (318mm)
Top of fireplace to 1’’ (25 mm) trim| 10’’ (254mm)

Mantel Requirements

WARNING
TOP STAND-OFF BRACKETS MUST BE ASSEMBLED AND ATTACHED TO FIREPLACE. DO NOT REMOVE. STAND-OFF BRACKETS ARE NOT LOAD BEARING
Non-Combustible Zone:
Rigid Pipe: 1’’ (25 mm) above elbow for entire width and depth (behind header) of fireplace.
Flexible Venting: 1’’ (25 mm) above elbow for entire width and depth (behind header) of fireplace.

AMBIANCE Intrigue 42 Fireplaces - Zone

CLEARANCES

Top of unit face to header (cement board may be used in this area).| 10’’ (254mm)
From unit left & right sides and back| 1/2’’ (13mm)
To flooring| 0’’ (0mm)
Unit top to ceiling| 31’’ (787mm)
Side of unit face to adjacent sidewall| 3’’ (76mm)
Mantel 9’’ (229mm) deep from top of fireplace| 12-1/2’’ (318mm)
Top of fireplace to 1’’ (25 mm) trim| 10’’ (254mm)

Typical Installation Options

IMPORTANT
The horizontal heat shield included with this fireplace must be installed when incorporating minimum horizontal venting. This applies to Nat. and LP minimum horizontal venting configurations.
Horizontal vent heat shield not shown in illustrations below for clarity purposes only.

Typical Horizontal Installation| Typical Corner Installation| Typical Vertical Installation
---|---|---
AMBIANCE Intrigue 42 Fireplaces - Horizontal
Installation| AMBIANCE Intrigue 42
Fireplaces - Corner Installation| AMBIANCE Intrigue 42 Fireplaces - Vertical
Installation

www.ambiancefireplaces.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Ambiance User Manuals

Related Manuals