AMBIANCE FIREPLACES Impressionist 34 Electric Collection Owner’s Manual

October 30, 2023
AMBIANCE FIREPLACES

AMBIANCE FIREPLACES Impressionist 34 Electric Collection

AMBIANCE FIREPLACES Impressionist 34 Electric
Collection

Dimension

Dimension

| ENERGY| ENERGY CONSUMPTION| FLAME MOTOR| HEATING AREA| BLOWER INCLUDED
---|---|---|---|---|---
Volts| Amps| Watts| High
Max 1500 w / Min 750 w| Off| Lamps

LED

| Rotor Motor| Area sq in

500

| CFM
120| 12.5| 1500 max| 22 watts| 1 to 5 watts| 100
GLASS| DIMENSIONS
---|---
34| Dimensions
13.25” X 30.625”| Area sq in
402| Height (A / D)
16.875” / 15.625”| Depth (C / E)
6.25” / 5.5”| Width (B / F)
34.5” / 32.375”| G
13.125”| H
30.625”| I
0.75”| J
0.75”
42| 13.25” X 40.375”| 561| 16.875” / 15.625”| 6.25” / 5.5”| 44.25” / 42.25”| 13.125”| 40.375”| 0.75”| 0.75”
50| 13.25” X 48.5”| 636| 16.875” / 15.625”| 6.25” / 5.5”| 52.25” / 50.25”| 13.125”| 48.375”| 0.75”| 0.75”
60| 13.25” X 58.375”| 766| 16.875” / 15.625”| 6.25” / 5.5”| 62.25” / 60.25”| 13.125”| 58.375”| 0.75”| 0.75”
74| 13.25” X 72.375”| 950| 16.875” / 15.625”| 6.25” / 5.5”| 76.25” / 74.25”| 13.125”| 72.375”| 0.75”| 0.75”
88| 13.25” X 86.375”| 1160| 16.875” / 15.625”| 6.25” / 5.5”| 90.25” / 88.25”| 13.125”| 86.375”| 0.75”| 0.75”
100| 13.25” X 98.375”| 1291| 16.875” / 15.625”| 6.25” / 5.5”| 102.25” / 100.25”| 13.125”| 98.375”| 0.75”| 0.75”

Framing and Clearances

Select a location that is not prone to moisture and is located at least 0.91m or 3 feet away from combustible materials such ascurtains, drapes, furniture, bedding, paper, etc.

The rough wall opening size of the fireplace:

| W (”)| D (”)| H (”)
---|---|---|---
AMB-IW-34-3| 32.875| 6| 16
AMB-IW-42-3| 42.75| 6| 16
AMB-IW-50-3| 50.75| 6| 16
AMB-IW-60-3| 60.75| 6| 16
AMB-IW-74-3| 74.75| 6| 16
AMB-IW-88-3| 88.75| 6| 16
AMB-IW-100-3| 100.75| 6| 16

Outdoor Installations

The Impressionists® electric fireplaces are suitable for installation in outdoor areas protected from direct water impingement.
In addition to maintaining the listed mantel and combustibles clearances, a rain protection overhang factor of 1/2 shall be constructed to the front and to each side of the installed appliance. See illustration below. All wiring connections to line power shall be in accordance with local building code requirements. Inquires about local codes and regulations must be done prior to installation.

The overhang (A) must extend at least 1/2 the roof-line height. Height is measured from the base of the fireplace.
For example: if the roof-line (B) is 8’ above the base of the fireplace, the overhang (A) must be at least 4’.