urban ambiance UQL2081 Crystal Flush Mount Ceiling Light Instruction Manual
- June 9, 2024
- urban ambiance
Table of Contents
- UQL2081 Crystal Flush Mount Ceiling Light
- Package Contents
- STEP 1 – Attach Inner Backplate to Outlet Box
- STEP 2 Remove the Protective film
- STEP 3 Make Wire Connections
- STEP 4 Attach Fixture Body to Mounting Screw
- STEP 5 – Install Bulb
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Installation Instructions:
SKU: UQL2081
UQL2081 Crystal Flush Mount Ceiling Light
Tools Required: Flathead screwdriver, Phillips screwdriver, pliers, wire
cutters, wire strippers, electrical tape, safety glasses.
Bulb Recommended: (5) G9 Base clear G9 Xenon bulb,40W Maximum
EstimatedAssembly Time: 20-30 minutes
Preparation: Identify and inspect all parts before beginning
installation. Check package content list and diagrams below to be sure all
parts are present. If any parts are missing or damaged, do not attempt to
assemble, install, or operate the fixture. Contact customer service for
replacement parts.
Warnings and Cautions
Turn off electricity at circuit breaker or main fuse box before installation.
Consult a licensed electrician if in doubt.
These instructions are provided for your safety. It is very important you read
them completely before installing the fixture. We strongly recommend that a
licensed, professional electrician perform the installation.
Disconnect fixture from power source before replacing bulbs. Make sure bulbs
are given sufficient time to cool before removal. Do not subject glass parts
to any shock while in operation or shattering June result.
Do not touch the bulb with bare hands use a cloth or glove.
Package Contents
Part | Description | Quantity |
---|---|---|
A | Inner Backplate | 1 pc. |
B | Washer | 4 pcs. |
C | Fixture Body | 1 pc. |
E | Crystal 3.63″L Part A | 18 pcs. |
F | Crystal 5″L Part B | 12 pcs. |
G | Crystal 5.63″L Part C | 6 pcs. |
H | Crystal 6.25″L Part D | 1 pc. |
I | Wall Anchor | 4 pcs. |
J | Self-tapping Screw | 4 pcs. |
K | Mounting Ball | 4 pcs. |
(5) 40W Maximum clear G9 Xenon (Supplied)
NOTE: ALL DIMENSIONS ARE ROUNDED UP TO THE NEAREST 1/2″
NO. | PART NUMBER | REPLACEMENT PART DESCRIPTION | REQ. |
---|---|---|---|
1 | UQL2081 BU | BULB 40W XENON G9 CLEAR | 5 |
2 | UQL2081CRA | DECORATIVE CRYSTAL BALL 3.63″L PART “A” | 18 |
3 | UQL2081CRB | DECORATIVE CRYSTAL BALL 5″L PART “B” | 12 |
4 | UQL2081 CRC | DECORATIVE CRYSTAL BALL 5.63″L PART “C” | 6 |
5 | UQL2081 CRD | DECORATIVE CRYSTAL BALL 6.25″L PART “D” | 1 |
STEP 1 – Attach Inner Backplate to Outlet Box
A. Place the Inner Backplate (A) onto the ceiling and line up one set of holes
onto mounting holes on Outlet Box. Using a pencil, mark the locations for Wall
Anchors (I).
B. Remove the Inner Backplate (A) and drill holes from the marks and then push
the Wall Anchors (I) into the holes.
C. Position the Inner Backplate (A) back onto the Ceiling. Thread the Outlet
Box Screws (not supplied) into the mounting holes on the Outlet Box to secure
it. Hand tighten until snug.
D. Pass the Washers (B) over the Self-tapping screws (J) and then thread the
self-tapping screws (J) into the Wall Anchors (I). Hand tighten until snug.
STEP 2 Remove the Protective film
A. Remove the Protective Film for Fixture Body (C).
STEP 3 Make Wire Connections
A. Use standard wire connectors to make all wire connections. (Connectors are
not included with fixture.) Strip and prepare wire ends according to
instructions supplied with connectors.
B. Connect White Supply Wire from the Outlet Box to White Wire from fixture.
C. Connect Black (or Red) Supply Wire from the Outlet Box to Black Wire from
fixture.
D. Connect Ground Wire from the Outlet Box to Ground Wire from fixture.
E. Twist connectors until wires are tightly joined together.
F. Wrap each connection with approved electrical tape and carefully stuff all
the connected wires into the Outlet Box.
STEP 4 Attach Fixture Body to Mounting Screw
A. Place the Fixture Body (C) over the Mounting Screws and secure with Mounting Balls (K). Hand tighten until snug.
STEP 5 – Install Bulb
A. Insert bulb and seat properly into place.
IMPORTANT: Do not touch the bulb with bare hands use a cloth or glove.
STEP 6 – Install Crystal to Fixture
A. Insert (H) to the hole on the Crystal 6.25”L Part D Crystal 5.63″L Part C
(G) to the hole on the ring C of center of Ceiling Canopy, Ceiling Canopy
Ceiling Canopy , Crystal 5″L Part B (F) to the hole on the ring B of , Ceiling
Canopy Crystal 3.63″L Part A (E) to the hole on the outside ring of .
Your fixture is now assembled and ready to use. Enjoy!
CAUTION FOR BULB REPLACING
A. When replace bulb, turn off power and allow lamp to cool. For safety
purpose, wear gloves and eye protection.
B. If bulb is scratched or cracked, DO NOT use the lamp to avoid breakage
during use or installation.
C. Use only in fixtures rated for lamps wattage and voltage.
D. Lamp operate under high pressure generating intense heat. Prevent contact
with liquid and combustible materials.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>