AMBIANCE Outlander 15 Wood Collection User Manual
- October 30, 2023
- Ambiance
Table of Contents
Outlander 15Wood Stove
Owner’s Manual
Model: Outlander® 15
Overall Dimensions
Leg Model
Top View
Pedestal Model
Specifications
BTU | FIREBOX | EFFICIENCIES | VENTING |
---|---|---|---|
Cordwood | EPA | Cu. Ft | Log Length |
52,000 | 30,042 | 1.9 | 20 |
GLASS | DIMENSIONS | BLOWER | |
--- | --- | --- | |
Type | Dimensions | Area sq in | Height |
Ceramic | 16.5” X 9.24” | 152 | 31.5” |
variable speed | 150 |
Framing and Clearances
PARALLEL & CORNER | SINGLE WALL CONNECTOR | DOUBLE WALL CONNECTOR |
---|---|---|
Sidewall (A) | 19″ (48.3 cm) | |
Sidewall to flue (B) | 28″ (73.3m) | |
Backwall (C) | 17.5″ (44.5 cm) | 12.5″ (31.8 cm) |
Backwall to flue (D) | 21″ (53.3 cm) | 16″ (40.6 cm) |
Corner (E) | 11″ (279 mm) | 7″ (178 mm) |
Ceiling (F) | 84″ (213.4 mm) | 75″ (190.5 cm) |
Clearances can be reduced with shielding acceptable to local authorities. Reduced installation must comply with NFPA 211 or CAN/CSA-B365.
Alcove Installation
Your appliance may be installed using a listed double wall connector, such as Security DL6 in Canada, the Simpson Duravent Plus DVL in the USA or an equivalent double wall connector, into an alcove having a depth of no more than 4 feet and a height of at least 6’3″. The minimum clearance are as shown.
ALCOVE
PARALLEL & CORNER| SINGLE WALL CONNECTOR| DOUBLE WALL CONNECTOR
Ceiling (G)| N/A| 7″ (190.5 cm)
Side wall (H)| 19″ (48.3 cm)
Sidewall to flue (I)| 28.875″ (73.3 cm)
Blackwall (J)| 12.5″ (31.8 cm)
Blackwall to flue (K)| 16″ (40.6 cm)
Floor protection
If the appliance is to be installed on top of a combustible floor, it must be
placed on an approved non-combustible hearth pad, that extends 8″ (203 mm)
beyond the appliance sides and back and 18″ (457 mm) in Canada / 16″ (406 mm)
in the USA to the front. The reduced clearance from the back of the appliance
may result in the appliance pad terminating shorter than 8″ (203 mm) beyond
the appliance.
note:
Floor protection is required for spark and ash shielding, but not for limiting
floor temperatures from the radiant heat of the appliance. The appliance was
designed and safety-tested so that without any protection, the floor would not
overheat.
Refer to local building codes for suitable floor protection
materials.
MINIMUM FLOOR PROTECTION
| FRONT (L)| SIDES (M)| BACK (N)
CANADA| 18″ (45.7 cm)| 8″ (203 mm)
USA| 16″ (406 mm)| 8″ (203 mm)
note:
If a section of horizontal chimney connector is used, floor protection is
required under the chimney connector and 2″ (51 mm) beyond each side.
Optional Blower Kit Installation
Provisions have been made on this appliance to install an optional blower kit (EPT70) that comes complete with a variable speed switch to turn blower ON/OFF, as well as to adjust the blower speed.
-
Ensure the thermal disc bracket is in the correct postion (Fig. 1).
-
Remove the knock-out from the back of the appliance.
-
Install the blower and housing as shown (Fig. 2) using 4 screws (supplied).
-
Loosen the adjustment screws.
-
Reach between the outer panel and the firebox, then slide the thermal disc bracket until the thermal disc is touching the rear of the firebox. (Fig. 1).
note:
For optimal perfomance, the thermal disc MUST make contact with the firebox. -
Re-secure the adjustement screws to hold the thermal disc bracket in place.