AMBIANCE Outlander 19 Wood Stove Owner’s Manual

October 30, 2023
Ambiance

Outlander 19 Wood Stove
Owner’s Manual

Model: Outlander® 19
Overall Dimensions

Outlander 19 Wood Stove

AMBIANCE Outlander 19 Wood Stove - diagram

Overall Dimensions

AMBIANCE Outlander 19 Wood Stove - diagram 1

Specifications

BTU     FIREBOX   EFFICIENCIES VENTING
Cordwood EPA Cu. Ft Log Length g / hr **Optimal
%** HHV Type Diameter
75,000 54,127 2.3 20 2.25 g 76 % 72 %

GLASS DIMENSIONS| BLOWER
---|---
Type| Dimensions| Area sq in| Height| Depth| Width| Type| CFM
Ceramic| 16.5” X 9.24”| 152| 31.5”| 24.63”| 26”| Optional – Heat activated, variable speed| 150

Framing and Clearances

AMBIANCE Outlander 19 Wood Stove - diagram 2

PARALLEL & CORNER SINGLE WALL CONNECTOR DOUBLE WALL CONNECTOR
Sidewall (A) 19″ (48.3 cm)
Sidewall to flue (B) 28″ (73.3m)
Backwall (C) 17.5″ (44.5 cm) 12.5″ (31.8 cm)
Backwall to flue (D) 21″ (53.3 cm) 16″ (40.6 cm)
Corner (E) 11″ (279 mm) 7″ (178 mm)
Ceiling (F) 84″ (213.4 mm) 75″ (190.5 cm)

Clearances can be reduced with shielding acceptable to local authorities. Reduced installation must comply with NFPA 211 or CAN/CSA-B365.

Alcove Installation

Your appliance may be installed using a listed double wall connector, such as Security DL6 in Canada, the Simpson Duravent Plus DVL in the USA or an equivalent double wall connector, into an alcove having a depth of no more than 4 feet and a height of at least 6’3″. The minimum clearance are as shown.AMBIANCE Outlander 19 Wood Stove - diagram 3

ALCOVE

PARALLEL & CORNER| SINGLE WALL CONNECTOR| DOUBLE WALL CONNECTOR
Ceiling (G)| N/A| 75″ (190.5 cm)
Side wall (H)| 19″ (48.3 cm)
Sidewall to flue (I)| 28.875″ (73.3 cm)
Blackwall (J)| 12.5″ (31.8 cm)
Blackwall to flue (K)| 16″ (40.6 cm)

Floor protection
If the appliance is to be installed on top of a combustible floor, it must be placed on an approved non-combustible hearth pad, that extends 8″ (203 mm) beyond the appliance sides and back and 18″ (457 mm) in Canada / 16″ (406 mm) in the USA to the front. The reduced clearance from the back of the appliance may result in the appliance pad terminating shorter than 8″ (203 mm) beyond the appliance.
note:
Floor protection is required for spark and ash shielding, but not for limiting floor temperatures from the radiant heat of the appliance. The appliance was designed and safety-tested so that without any protection, the floor would not overheat.
Refer to local building codes for suitable floor protection materials.AMBIANCE Outlander 19 Wood Stove - diagram 4

MINIMUM FLOOR PROTECTION

 | FRONT (L)| SIDES (M)| BACK (N)
CANADA| 18″ (45.7 cm)| 8″ (203 mm)
USA| 16″ (406 mm)| 8″ (203 mm)

note:
Floor protection is required for spark and ash shielding, but not for limiting floor temperatures from the radiant heat of the appliance. The appliance was designed and safety-tested so that without any protection, the floor would not overheat.

Optional Blower Kit Installation

AMBIANCE Outlander 19 Wood Stove - diagram 5

Provisions have been made on this appliance to install an optional blower kit (EPT70) that comes complete with a variable speed switch to turn blower ON/OFF, as well as to adjust the blower speed.

  1. Ensure the thermal disc bracket is in the correct postion (Fig. 5-1).AMBIANCE Outlander 19 Wood Stove - diagram 6

  2. Remove the knock-out from the back of the appliance.

  3.  Install the blower and housing as shown (Fig. 5-2) using 4 screws (supplied). AMBIANCE Outlander 19 Wood Stove - diagram 7

  4. Loosen the adjustment screws.

  5. Reach between the outer panel and the firebox, then slide the thermal disc bracket until the thermal disc is touching the rear of the firebox. (Fig. 5-1).
    note:
    For optimal perfomance, the thermal disc MUST make contact with the firebox.

  6. Re-secure the adjustement screws to hold the thermal disc bracket in place.