AMBIANCE Illusion 47 Built In Direct Vent Fireplace Owner’s Manual
- October 30, 2023
- Ambiance
Table of Contents
Illusion 47 Built In Direct Vent Fireplace
Owner’s Manual
Illusion 47 Built In Direct Vent Fireplace
BTU | VENTING | GLASS |
---|---|---|
Max NG | Max LP | Min NG |
Dimensions | Surface | |
24,000 | 24,000 | 17,000 |
x 16.75” | 698 sq in | |
DIMENSIONS | FRAMING DIMENSIONS | OPTIONAL BLOWER |
SHELF CLEARANCE**
---|---|---|---
Height| Depth| Width| Height| Depth| Width| Type| CFM| Shelf depth| Height
from bottom of fireplace
39.0625”| 18.3125”| 46.875”| 41.5”| 18.625”| 47.375”| Heat Activated, 6
speeds| 150| 6”| 43”
Framing and Clearances
3.1 minimum framing dimensions
note:
The minimum clearances from the top of the horizontal vent pipe to combustible
materials may be reduced from 3’’ (76mm) to 1’’ (25mm) in those installations
with a minimum 38’’ (96.5cm) vertical vent rise made immediately off the
appliance collar.
A | 18 9/16’’ (47.1cm) |
---|---|
B | 47 3/8’’ (120.3cm) |
C | 42 1/2’’ (107.9cm) |
D | 6 5/16’’ (16cm) |
E | 60 3/16’’ (152.9cm) |
F | 6’’ (15.2cm) |
WARNING
- Do not build this area – it must be left clear to provide adequate clearance for the vent in this 14’’ (35.6cm) wide area centered along the front of the appliance. The appliance should be in its final location before framing.
B | 47 3/8’’ (120.3cm) |
---|---|
G | 39 3/8’’ (100cm) |
A | 18 9/16’’ (47.1cm) |
H | 56’’ (142.2cm) |
10.3 minimum clearance to combustible enclosures
note:
When passing through a wall, use firestop spacer W010-4404 (supplied).
When passing through a ceiling, use firestop spacer W500-0096 (not
supplied). note:
The vent shield is telescopic and must be adjusted to shield the full depth of
the combustible wall penetration.
*See «venting requirements» and «venting installation» sections.
Clearances within the enclosure may be higher, see «minimum framing
dimensions» section.
11.2 minimum clearance to combustible enclosures
WARNING**
- Non-combustible facing material must not project more than 4’’ (102mm) from the face of the door (all three sides). If greater projections are desired, increase the clearance to the sides and top by 2’’ (51mm) for every additional 1’’ (25mm) of projection. If using an optional surround, the same rules applies, starting from the top of the surround. Ensure clearances are maintained for surround removal, as it must life of the appliance for maintenance.
K | 48’’ (121.9cm) |
---|---|
L | 42 1/2’’ (107.9cm) |
Minimum combustible mantel clearances
Combustible Mantel clearance can vary according to the mantel depth. Use the graph to help evaluate the clear-ance needed.
MANTEL DIMENSIONS
Ref| Height| Depth
N| 27 1/2″ (69.9cm)| N/A
0| 12″ (30.5cm)| 2″ (51mm)
P| 14″ (35.6cm)| 4″ (102mm)
Q| 16″ (40.6cm)| 6″ (153mm)
R| 18″ (45.7cm)| 8″ (203mm)
ONLY if the Universal Heat Management System is installed, mantel clearances can be reduced.
MANDEL DIMENSIONS (WITH UHM)
Ref| Height| Depth’
0| 24(5 mm)
P| 4″ (102mm)
Q| 6″ (153mm)
R| 8″ (203mm)
WARNING
- Risk of fire! Reduced mantel clearances are ONLY acceptable for applications with UHM installed.
- Mantel depth must be appropriately sized if placing any valuable items above the fireplace / mantel (see “clearances around appliance (TV and valuable objects)”).
Clearances around appliance (TV and valuable objects) * TV applications were tested with the minimum enclosure dimensions and the maximum recess permissible. This data is provided in good faith and is not a guarantee for every application and television. Care and consideration should be taken when planning these installations to ensure the temperatures around the TV meet all manufacturer’s recommended operating temperatures. Increasing the height of the mantel and/or TV above the fireplace opening, the protrusion of mantel and the volume of the enclosure all have the effect of reducing the temperature above the fireplace. It is always recommended to use the optional heat management kit when considering mounting a television above the fireplace.
Optional heat management system
The Universal Heat Management system is an optional gravity vent kit that
allows you to manage the heat produced by the appliance at and around the
fireplace.
We recommend installing the Universal Heat Management system kit during the
installation of the appliance BEFORE the gas is installed.
For more information, contact your local authorized dealer.