MULTIPLEX MA-8-2 Blend-in-Cup Instructions
- October 30, 2023
- MULTIPLEX
Table of Contents
MA-8-2 Blend-in-Cup
Multiplex BIC MF Ice Shaver Belt Replacement Instructions
Multiplex is a company that offers a range of beverage dispensing solutions. The BIC MF Ice Shaver Belt is a replacement part for the Blend-in-Cup (BIC) units, including MA-8-2, MA-8-2BF, and MA-8-2AF.
Instructions for Replacement
Before beginning the replacement process, please ensure that the unit is turned OFF and unplugged. Follow the instructions below for a successful replacement:
- Power OFF the unit using the switch located on the LEFT side of the unit and unplug it. Place an empty bucket under the drain if necessary.
- Remove the two (2) Phillips head screws that secure the top rear panel and set the panel aside. Keep the refrigeration cabinet door closed so that the product remains chilled.
- Remove the mounting bracket that contains the power supply, relays, and SRB. Remove the screw(s) that secure the mounting bracket to the unit. Slightly lift the bracket, releasing the right-side hinge, then carefully lower the bracket down towards the lower refrigerated cabinet.
- Mark the position of the motor on the mounting bracket by marking a line along the edge of the motor onto the mounting bracket.
- Locate the two (2) hex head bolts that secure the Hall Effect Sensor Bracket to the shaver motor mounting bracket.
- Completely remove the two (2) bolts that secure the Hall Effect sensor mounting bracket to the motor mounting bracket. Move Hall Effect sensor bracket aside.
- Loosen the two (2) bolts that secure the motor to the mounting bracket.
- Push the motor towards the front of the unit to disengage the ice shaver belt. Remove the old ice shaver belt.
- Install the new ice shaver belt over the pillow block pulley and the ice shaver motor pulley.
- Locate the line marking the motor position on the mounting bracket and move the motor back into place.
- Confirm that the end of the Hall Effect Sensor is 1/16 inch (1.6mm) from the edge of the bracket. An American or Canadian dime is approximately 1/16 inch (1.6mm) thick.
- Install Hall Effect Sensor Bracket Assembly to the motor mounting bracket using the two (2) bolts. Verify wire restraint with grounding wire has been secured with the left bolt.
- Confirm that the end of the Hall Effect Sensor did not shift and is still 1/16 inch (1.6mm) from the edge of the sensor bracket.
- If necessary, apply a thin layer of dielectric grease to the Hall Effect Sensor to protect against condensation.
- Plug in the unit and power it ON.
Note that there are two different User Interface (UI) screens used on BIC units, and on-screen options vary by screen. Please refer to the picture below for UI screen reference names.
When working near heat sinks, use extreme caution as they may contain electric power even after the unit has been powered OFF and disconnected from the power source.
For further assistance or information, please contact Multiplex’s customer care at 844-724-CARE or visit their website at: www.multiplexbeverage.com.
Instruction Sheet
TOOLS REQUIRED
- Safety Gloves (cut resistant)
- Needle Nose Pliers
- Screw Drivers, Phillips & Flat Head
- 3/8” or ¼” Drive Socket Set (3/8” and 5/16”)
- Standard Open End Wrench Set
- Pencil or Marker
- Food Grade Scale ( measures to at least one decimal point)
PARTS REQUIRED
- VMP00123 Ice Shaver Belt
- Dielectric Grease
Important
Keep refrigeration cabinet door closed so product remains chilled.
WARNING
Heat sinks may contain electric power even after unit has been powered OFF and
disconnected from power source. Use extreme caution when working near the heat
sinks to prevent electric shock.
NOTE: There are two different User Interface (UI) screens that are used on Blend-in-Cup (BIC) units. Onscreen options vary by screen. Please see picture below for the UI screen reference names.
REPLACEMENT INSTRUCTION
-
Power unit OFF using switch located on LEFT side of unit and unplug. Place an empty bucket under drain if necessary.
-
Remove the two (2) Phillips head screws that secure the top rear panel and set panel aside. WARNING
Heat sinks may contain electric power even after unit has been powered OFF and disconnected from power source. Use extreme caution when working near the heat sinks to prevent electric shock. -
Remove the mounting bracket that contains the power supply, relays and SRB.
- Remove the screw(s) that secures the mounting bracket to the unit.
- Slightly lift the bracket releasing the right side hinge then carefully lower the bracket down towards the lower refrigerated cabinet.
-
Mark the position of the motor on the mounting bracket by marking a line along the edge of the motor onto the mounting bracket.
-
Locate the two (2) hex head bolts that secure the Hall Effect Sensor Bracket to the shaver motor mounting bracket.
-
Completely remove the two (2) bolts that secure the Hall Effect sensor mounting bracket to the motor mounting bracket. Move Hall Effect sensor bracket aside.
-
Loosen the two (2) bolts that secure the motor to the mounting bracket.
-
Push motor towards front of unit to disengage ice shaver belt. Remove old ice shaver belt.
-
Install new ice shaver belt over the pillow block pulley and the ice shaver motor pulley.
-
Locate the line marking the motor position on the mounting bracket and move the motor back into place.
-
While holding the motor in position tighten the two (2) bolts to secure the motor to the motor mounting bracket. Push on the center of the belt between both pulleys. The belt should deflect about ¼ to 3/8” (6.3-9.5mm).
-
Confirm the end of the Hall Effect Sensor is 1/16 inch (1.6mm) from the edge of the bracket.
NOTE: An United States or Canadian dime is approximately 1/16 inch (1.6mm) thick. -
Install Hall Effect Sensor Bracket Assembly to the motor mounting bracket using the two (2) bolts. Verify wire restraint with grounding wire has been secured with the left bolt.
-
Confirm the end of the Hall Effect Sensor did not shift and is still is 1/16 inch (1.6mm) from the edge of the sensor bracket.
-
Apply a thin layer of dielectric grease to the Hall Effect Sensor if necessary to protect against condensation.
-
Lift the bracket containing power supplies and SRB back into place. Verify the bracket hinges are seated fully into slots in the frame of the unit.
-
Reinstall the screw(s) that secures the SRB and power relay mounting bracket to the unit.
-
Plug unit IN and power ON. TEST ICE SHAVER BELT
Test the ice shaver belt has been installed correctly by running the ice motor and observing the ice shaver belt operates correctly and is secure.
FOR MR7 SCREENS -
Test the ice shaver belt.
- Place container in ice dispense area to collect ice from dispense test.
- From easyTouch Screen press MANAGER MENU.
- Press A then GREEN check.
- Press DOWN arrow.
- Press SERVICE.
- Press A then GREEN check.
- Press OUTPUTS.
- Press DOWN arrow.
- Change ICE MOTOR state to ON.
- Observe ice shaver belt operation.
- Wait ten (10) seconds then change ICE MOTOR state to OFF.
- Press BACK arrow to return to easy ToUCH screen.
FOR COMMON CONTROLLER SCREENS
-
Test the ice shaver belt.
- Place container in ice dispense area to collect ice from dispense test.
- From easyTouch Screen press SERVICE.
- Press A then GREEN check.
- Press OUTPUTS.
- Scroll down and change ICE MOTOR state to ON.
- Observe ice shaver belt operation.
- Wait ten (10) seconds then change ICE MOTOR state to OFF.
- Press BACK arrow to return to easyToUCH screen.
ICE CALIBRATION
NOTE: Verify ice bin is at least half full of ice before starting ice calibration.
FOR MR7 SCREENS
-
Perform Ice Calibration
- From easyTouch Screen press MANAGER MENU.
- Press A then GREEN check.
- Press CONFIGURE SLOTS.
- Press CALIBRATE FLAVOR.
- Press ICE.
- Follow onscreen instructions.
- Press BACK arrow to return to easyToUCH screen.
FOR COMMON CONTROLLER SCREENS
-
Perform Ice Calibration
- From easyTouch Screen press SETTINGS.
- Press A then GREEN check.
- Press CONFIGURE SLOTS.
- Press CALIBRATE FLAVOR.
- Press ICE.
- Follow onscreen instructions.
- Press BACK arrow to return to easyToUCH screen.
CONFIRM OPERATION
-
Make a SMALL, MEDIUM and LARGE drink to confirm operation. Correct issues if necessary.
-
Reinstall top rear panel and secure with the two (2) screws.
-
Move unit into place.
-
Verify drain is connected correctly.
-
Make several drinks with manager present to confirm operation.
Document Number: MPX-i-076 October 06, 2022
Read User Manual Online (PDF format)