MULTIPLEX 020009187 Beverage Racks Instructions
- June 9, 2024
- MULTIPLEX
Table of Contents
020009187 Beverage Racks
Instructions
020009187 Beverage Racks
Instruction Sheet
Subject: Racks
SCOPE: MULTIPLEX RACKS
Racks can be configured with a variety of options for usage and space
requirements This instruction covers basic assembly and installation.
TOOLS REQUIRED
- Safety Gloves (cut resistant)
- Screw Drivers, Phillips & Flat Head
- Tubing Cutters
- Oetiker Pliers
- Needle Nose Pliers
PARTS REQUIRED
- Zip Ties
- Rack System Kit
Warning
Carbon Dioxide (CO2 ) displaces oxygen. Exposure to a high concentration of
CO2 gas causes tremors, which are followed rapidly by loss of consciousness
and suffocation. If a CO2 gas leak is suspected, particularly in a small area,
turn off CO2 supply and immediately ventilate the area before repairing the
leak. CO2 lines and pumps must not be installed in an enclosed space. An
enclosed space can be a cooler or small room or closet. This may include
convenience stores with glass door self serve coolers. If you suspect CO2 may
build up in an area, venting of the BIB pumps and/or CO2 monitors must be
utilized.
INSTRUCTION
-
Assemble rack. See Rack Assembly Diagrams (PN 020009186). Verify shelves are securely inserted into rack uprights.
-
Assemble the regulator.
A. Install mounting clip onto back of regulator.
NOTE: If using two regulators both regulators each require a mounting clip.
B. Install washer into beverage fitting then install fitting on regulator.
NOTE: Beverage fitting may be straight or elbow.
C. Fittings on single regulator assembly pictured below.
-
Install hanger clips onto the product pumps. See “Product Pump and Regulator Configuration Samples” on page 4.
-
Arrange product pumps and regulator(s) in place on rack.
NOTE: Product pump and regulator series configurations will vary by application. See “Product Pump and Regulator Configuration Samples” on page 4. for examples of different configurations.
NOTE: Gas tubing from regulator to pump series needs to be in a continuous circuit with regulator at beginning and last product pump with end- fitting at the end of the circuit.
-
Make sure last pump in series has a single fitting connection and all other pumps in series have T fittings.
-
Install gas tubing between regulator and first pump in the series using Oetiker clamps.
-
Install gas tubing between each pump in the series. It may be easier to remove the fitting, install the tubing then reinstall fitting onto pump.
-
Install gas tubing from first pump in series to the regulator on the rack.
-
If applicable connect each syrup pump exhaust to vent outside of closed space.
Warning
When installing rack inside closed space pump exhausts MUST be exhausted outside closed space. -
Install gas tubing from regulator on rack to regulator on tank.
-
Install product/syrup tubing. Leave 12 inches (30.5cm) excess at front of rack for syrup bag connector.
-
Connect each syrup tube line to pumps using Oetiker clamp.
-
Connect each end of syrup tube to syrup BIB connector using Oetiker clamp.
-
Carefully arrange tubing along rear of rack and loosely zip tie together. Do NOT over tighten zip ties.
PUMP HANGER CONFIGURATIONS
FLOJET
Pumps have two mounting options.
|
---|---
Back Mount
(Flush against rack)| Side Mount
(Protrudes out from rack)
SHURFLO
Pumps have two mounting options.
|
---|---
Back Mount
(Flush against rack)| Side Mount
(Protrudes out from rack)
PRODUCT PUMP AND REGULATOR CONFIGURATION SAMPLES
Actual configuration may vary from sample pictures below.
Document Number: 020009187 June 14, 2022MULTIPLEX
645 PARK EAST BLVD SUITE 5, NEW ALBANY, IN 47150
844-724-CARE
WWW.MULTIPLEXBEVERAGE.COM