Safety information

These operating instructions are part of the product. They contain important information and safety advice. It should therefore be kept at hand and passed on when selling the product to third parties. Please read carefully before initial use. For intended use only.

CE declaration of conformity
The device was evaluated according to directives harmonized with European legislation. You are therefore in possession of a product whose construction satisfies the protection objectives of the European Community for the safe operation of devices. Use a sufficient power supply dimension. Observe installation instructions. Con-duct range tests regularly.

Guarantee and limitation of liability
MULTIPLEX Modellsport GmbH & Co.KG does not assume any liability for loss, damage or costs which arise through the improper use and operation of our products, or which are connected with such operation in any way. As far as is legally permissible, the obligation of MULTIPLEX Modellsport GmbH & Co.KG to provide compensation for damages, on whatever legal basis, is limited to the invoice amount of the quantity of MULTIPLEX Modellsport GmbH & Co.KG goods that were directly affected by whatever incident gave rise to the damage. This does not apply if MULTIPLEX Modellsport GmbH & Co.KG is obliged to accept unlimited liability in accordance with mandatory law for deliberate or gross negligence. Our products are covered by the currently valid statutory guarantee regulations. If you wish to make a claim under guarantee, please contact the model shop where you purchased the product. The guarantee does not cover malfunctions caused by the following:

Disposal

Electrical and electronic equipment which has the crossed out wheelie bin symbol should not be disposed along with household waste, but rather via a suitable disposal system. In countries belonging to the EU (European Union), electrical or electronic equipment may not be disposed of along with general household waste (WEEE – Waste of Electrical and Electronic Equipment, Directive 2002/96/EC).

  •  Improper operation
  •  Maintenance that was performed incorrectly, late or not at all, or performed by a non-authorized body
  •  Incorrect connections
  •  Use of non-original MULTIPLEX accessories
  •  Modifications/repairs that were not carried out by MULTIPLEX or a MULTIPLEX Service Centre
  •  Accidental or deliberate damage
  •  Faults due to normal wear and tear
  •  Operation outside the technical specifications or in connection with components from other manufacturers.
  • MULTIPLEX Modellsport GmbH & Co.KG
  • Westliche Gewerbestraße 1 · D-75015 Bretten-Gölshausen Multiplex/HiTEC Service: +49 (0) 7252 – 5 80 93 33

You can dispose of your old equipment at public municipal collection points (e.g. recycling facilities) free of charge. The equipment will be properly disposed of free of charge here. By returning your old equipment, you are making a valuable contribution towards environmental protection!

Features

  •  SMD technology, long-life, vibration-resistant
  •  High-quality gold-plated connector systems and large cable cross-sections
  •  High continuous current load capacity thanks to large-area cooling via the milled aluminum housing
  •  Low power dissipation due to «ideal» diodes simulated by FET.
  •  Safe battery connection through MPX M6 connector and safety clips
  •  Compact construction and elegant design
  •  Fail-safe: If the switch or its connection cable is defective, the electronics ensure that the switching state is ON
  • I. e. Even if the switch vibrates down during flight, the power supply to the RC system is still ensured.
  •  Two receiver connection cables for double the wire cross-section and double the number of contacts with SAFETY-SWITCH PRO
  •  MPX M6 high-current connection with SAFETY-SWITCH PRO TwinBatt (M6) for direct connection to the MULTIPLEX receiver RX-9/12/16-DR pro
  • M- LINK or other receivers established on the market with M6 input.
  •  Integrated battery switch in the SAFETY-SWITCH PROTwinBatt. The batteries are discharged simultaneously and evenly.
  • If one battery fails, the second battery takes over the receiver power supply alone.
  •  It is also possible to connect a BEC of an ESC controller and a buffer battery. With this combination, make sure that the BEC voltage is higher than the voltage of the buffer battery. e.g .: The BEC voltage is 8v, then the backup battery is discharged down to 8v, from then on only the BEC will be discharged. If the BEC should collapse, the backup battery will be discharged again.
  •  Switch connection socket for free selection of your MPX switch. (Magnetic safety switch / Professional safety switch / Micro safety switch)
  •  LED status display on the housing
  •  Additional plug-in LED cable with a modern 3mm flat head LED to display the switching status.

Contents

  • SAFETY SWITCH PRO / Twinbatt
  • 4 Befestigungsschrauben
  • LED Kabel 30cm
  • Anleitung (dreisprachig)

 Specification

The mentioned quiescent current flows in the OFF position of the connected safety switch. Therefore remove the receiver battery from the model when storing it for a long period of time SAFETY-SWITCH off! In this way, you prevent the receiver battery from becoming completely discharged.

Assembly and commissioning

  1.  Attach the SAFETY SWITCH PRO power supply to the model so that it is protected from vibrations and shocks.

  2.  Connect the UNI connection cable (RX) to the battery slot of your receiver. Connect the second UNI connection cable (RX) to any free servo slot or, if applicable, to the second battery slot of the receiver.
    Note
    When connecting the UNI connection cable (s) (RX), ensure that the plug-in direction is correct, especially when using third-party products Pay attention to compatible contact assignment.
    SAFETY SWITCH PRO TwinBatt (M6): Connect the two-core connection cable (RX) to the M6 socket
    and the M6 plug of the MULTIPLEX receiver RX- 9/12/16-DR pro M-LINK.

  3.  When using the safety switch, place it anywhere in the model, as far as possible protected against accidental actuation. Connect the 4 – 6 cell NiXX or 2S LiXX battery pack (s) to the connection (s) of the SAFETY-SWITCH PRO marked with «BATT». Pay attention to correct polarity.

  4.  The enclosed LED cable can be installed in the model or led outside. To do this, a 3mm hole must be drilled, then you can fix the LED flush with the outer wall of the fuselage with a drop of Zacki from the inside.

Functionality

  • The switch cable is a safety-relevant component in the receiver power supply chain. Conventional switch cables with purely mechanical switches provide e.g. Due to aging phenomena (vibration, wear and tear, corrosion) on the switch contacts after a certain period of use, a safety risk due to failure. In addition, the demands on a switch cable increase due to the power requirements of modern high-performance servos. Many conventional, purely mechanical switch cables are not up to the task.

  • The receiver battery (s) is / are connected directly to the switch board of the SAFETY-SWITCH PRO. The connection to the
    The receiver takes place via a direct short power supply without a mechanical switching element. The switching function is performed by vibration-proof, fail-safe high-performance FETs, which have a very low internal resistance compared to mechanical switches. In connection with high-quality gold contacts and large cable cross-sections, the servos can really develop their performance.

  • As a switching element, you can choose the right one for you and your application from our three safety switches.
    (# 1-01784 Magnetic safety switch / # 85196 Professional safety switch / # 85195 Micro safety switch)
    The load current does not flow through the connected switch. The switch only gives the ON / OFF switching pulse. You can install the switch in any easily accessible location in the model.

Accessories

MULTIPLEX-Neue-Safety-Switch-PRO-Voltmaster-
FIG-1

  • Sicherheitsschalter Magnetic # 1-01784
  • Sicherheitsschalter Professional # 85196
  • Sicherheitsschalter Micro # 85195
  • LED Kabel Safety Switch Pro # 1-02080

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

MULTIPLEX User Manuals

Related Manuals