Subject: BIC LMS Valve Replacement
SCOPE: MULTIPLEX BIC UNITS MA-8-2, MA-8-2BF, MA-8-2AF

TOOLS REQUIRED

  • Safety Gloves (cut resistant)
  • Oetiker Pliers (PN 00681815)
  • Needle Nose Pliers
  • Screw Drivers, Phillips & Flat Head
  • 3/8” or ¼” Drive Socket Set (3/8” and 5/16”)
  • Cleaning Manifold & Cleaning Buckets (store supplied)

PARTS REQUIRED

  • Food Grade Lubricant
  • Replacement parts listed below:
QTY DESCRIPTION PART NUMBER
9 Valve, Dispense Outlet, LMS 1706172
9 15.7 Oetiker Clamp 15.7-706R

NOTE: There are two different User Interface (UI) screens that are used on Blend-in-Cup (BIC) units. See below for reference names. MULTIPLEX
1706172 BIC LMS Valve - fig 1

DISPENSE MOUNTING PLATE

MULTIPLEX 1706172 BIC LMS Valve - fig 2

INSTRUCTION

1. Verify operation of unit with manager. Make notes and take pictures of any issues.
2. Move all product/bins from lower refrigerated cabinet to store’s walk-in cooler.
3. Rinse and empty product lines by running product pumps. Use warm water to make lines more pliable.
A. Place cup in dispense area.
B. Fill cleaning bucket with warm water.
C. Connect cleaning manifold to product pumps and place other end of manifold in bucket of warm water.
D. Use touchscreen to operate solenoids
FOR MR7

  • Press the BACK arrow to return to easyToUCH screen
  • Press MANAGER Menu. Press A then GREEN check
  • Press DOWN arrow then press SERVICE
  • Press A then press GREEN check
  • Press OUTPUTS
  • Toggle each flavor solenoid ON until line runs clear then toggle OFF. Repeat for each of the eight (8) solenoids.

FOR COMMON CONTROLLER

  • From easyToUCH screen press SERVICE
  • Press A then GREEN check
  • Press OUTPUTS
  • Toggle each flavor solenoid ON until line runs clear then toggle OFF. Repeat for each of the eight (8) solenoids.

4. Locate the dispense valve mounting plate in the top center of the dispensing area. Remove the four (4) outer screws that secure the mounting plate in place.MULTIPLEX 1706172 BIC LMS Valve - fig 3 CAUTION
Using too much force while pulling down on the plastic mounting plate could cause damage to the plate.
CAUTION
Be extremely careful when pulling down on the mounting plate to prevent product tubes from disconnecting. If product tubes disconnect and slip into the chase it will be very difficult to retrieve the product tubes.
5. Pull gently down on the mounting plate until the product tubing can be accessed. With the tubing now accessible pull down on the tubing lowering the dispense manifold as far down as possible. Now locate the tubing inside of the refrigerated cabinet. MULTIPLEX 1706172 BIC LMS Valve - fig
46. The tubing is towards the upper right rear inside of the cabinet and is separated by the chase that runs upwards towards the dispensing area. Push the tubing upwards as far as possible. Return to the dispense area and pull the tubing downwards as far as possible.
7. Return to the inside of the cabinet and push the tubing upwards as far as possible.
8. Repeat the pulling of the tubing downwards in the dispense area and the pushing up of the tubing inside of the cabinet until the top of the dispensing plate is easily accessible.MULTIPLEX 1706172 BIC LMS Valve - fig
59. Locate the three (3) sets of LMS valve blocks. MULTIPLEX 1706172 BIC LMS Valve - fig 6

10. Starting with the valve block labeled number one (1) as shown above, remove the two (2) screws from the metal mounting plate for tubes labeled 5-7. MULTIPLEX 1706172 BIC LMS Valve - fig 7NOTE: The tubing is numbered and will need to be returned to the same position within the dispensing mounting plate following the replacement of the LMS valves. See “DISPENSE MOUNTING PLATE” on page 1.
11. Remove the remaining two (2) blocks of three (3) valves from the dispense mounting plate.
12. Wash, rinse, and sanitize the dispense mounting plate.
13. Starting with mounting block one (1) with tubes 5-7, use Oetiker pliers to cut and remove the existing Oetiker clamps that secure the product tubing to the LMS valve. MULTIPLEX 1706172 BIC LMS Valve - fig
8

14. Remove the old LMS valves and Oetiker clamps and discard. Install the new LMS valves using new Oetiker clamps to secure valves to tubing.
15. Repeat steps to replace valves in block two (2) then block three (3). It is recommended replace valves one block at time, starting with the blocks towards the rear of the machine first.
16. Reconnect the valve blocks to the dispense mounting plate.
NOTE: The product tubing MUST be in the correct position. See “DISPENSE MOUNTING PLATE” on page 1.
17. Reposition the dispensing mounting plate to the top of the dispensing area and secure with the four (4) outer screws. MULTIPLEX 1706172 BIC LMS
Valve - fig 918. Reverse actions in Step 6 pulling the tubing downwards within the refrigerated cabinet and pushing the tubing upwards in the dispensing area towards the inside of the tubing chase.
19. Verify cabinet temperature is 39°F (4°C) or below.
FOR MR7

  • From easyToUCH screen press the RECIPE BOOK
  • From drink making screen the cabinet temperature will display in the top LEFT corner

FOR COMMON CONTROLLER

From easyToUCH screen temperature will display in the top LEFT corner
20. After cabinet temperature reaches 39°F (4°C) or below reinstall product bags and bins in correct slots.
21. Prime product lines. Only prime lines that have product bags installed.
A. Put a cup under the dispense area.
B. Use touchscreen to operate solenoids. See STEP 3
D on page 1.
C. Empty cup in dispense area as needed. Do NOT pour down the unit drains.

CONFIRM OPERATION

22. With the manager present make sample drinks of each size.
23. Confirm operation of all functions.