Features

  • Universal AC input / Full range
  • Built-in active PFC function, PF>0.93
  • Protections: Short circuit / Overload / Over voltage / Over temperature
  • Built-in constant current limiting circuit
  • Remote ON-OFF control(Optional)
  • LED indicator for power on
  • 100% full load burn-in test
  • Fixed switching frequency at PFC:67KHz PWM:134KHz
  • 3 years warranty

SPECIFICATION

MODEL

| SP-150-3.3| SP-150-5| SP-150-7.5| SP-150-12| SP-150-13.5| SP-150-15| SP-150-24| SP-150-27|

SP-150-48

---|---|---|---|---|---|---|---|---|---
OUTPUT| DC VOLTAGE| 3.3V| 5V| 7.5V| 12V| 13.5V| 15V| 24V| 27V| 48V
RATED CURRENT| 30A| 30A| 20A| 12.5A| 11.2A| 10A| 6.3A| 5.6A| 3.2A
CURRENT RANGE| 0 ~ 30A| 0 ~ 30A| 0 ~ 20A| 0 ~ 12.5A| 0 ~ 11.2A| 0 ~ 10A| 0 ~ 6.3A| 0 ~ 5.6A| 0 ~ 3.2A
RATED POWER| 99W| 150W| 150W| 150W| 151.2W| 150W| 150W| 151.2W| 153.6W
RIPPLE & NOISE (max.) **Note.2| 100mVp-p| 100mVp-p| 100mVp-p| 100mVp-p| 100mVp-p| 100mVp-p| 150mVp-p| 150mVp-p| 250mVp-p
VOLTAGE ADJ. RANGE| 3.14 ~ 3.63V| 4.75 ~ 5.5V| 7.13 ~ 8.25V| 11.4 ~ 13.2V| 12.8 ~ 14.9V| 14.3 ~ 16.5V| 22.8 ~ 26.4V| 25.7 ~ 29.7V| 45.6 ~ 52.8V
VOLTAGE TOLERANCE Note.3| ±2.0%| ±2.0%| ±2.0%| ±2.0%| ±2.0%| ±2.0%| ±1.0%| ±1.0%| ±1.0%
LINE REGULATION| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
LOAD REGULATION| ±1.0%| ±1.0%| ±1.0%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
SETUP, RISE TIME| 700ms, 40ms at full load
HOLD UP TIME (Typ.)| 20ms at full load
INPUT| VOLTAGE                                    RANGE| 85 ~ 264VAC         120 ~ 370VDC
FREQUENCY RANGE| 47 ~ 63Hz
POWER FACTOR (Typ.)| PF>0.93/230VAC         PF>0.97/115VAC at full load
EFFICIENCY (Typ.)| 73%| 77.5%| 81%| 84%| 84%| 85%| 85%| 85%| 85%
AC CURRENT (Typ.)| 2.5A/115VAC        1.2A/230VAC
INRUSH CURRENT (Typ.)| COLD START 45A/230VAC
LEAKAGE CURRENT| <2mA / 240VAC
PROTECTION| ****OVERLOAD| 105 ~ 150% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
OVER VOLTAGE| 3.63 ~ 4.46V| 5.5 ~ 6.75V| 8.25 ~ 10.13V| 13.2 ~ 16.2V| 14.85 ~ 18.2V| 16.5 ~ 20.25V| 26.4 ~ 32.4V| 29.7 ~ 36.45V| 52.8 ~ 64.8V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE| Shut down o/p voltage, recovers automatically after temperature goes down
FUNCTION| REMOTE CONTROL(OPTION)| CN1:4 ~ 10VDC POWER ON, <0 ~ 0.8VDC POWER OFF
ENVIRONMENT| WORKING TEMP.| -10 ~ +55℃ (Refer to output load derating curve)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -20 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.05%/℃ (0 ~ 50℃)
VIBRATION**| 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes

SAFETY & EMC

| SAFETY STANDARDS| UL60950-1 approved
WITHSTAND VOLTAGE| I/P-O/P:3KVAC     I/P-FG:2KVAC     O/P-FG:0.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION| Compliance to EN55032 (CISPR32) Class B,EN61000-3-2,-3
EMC IMMUNITY| Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level,   criteria A

OTHERS

| MTBF| 191.2K hrs. min.      MIL-HDBK-217F (25℃)
DIMENSION| 1999950mm (LWH)
PACKING| 0.76Kg; 20pcs/16.4Kg/1.21CUFT
NOTE|

  • All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
  • Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
  • Tolerance : includes set up tolerance, line regulation and load regulation.
  • The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com)
  • Derating may be needed under low input voltages. Please check the derating curve for more details.
  • Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
Mechanical Specification

MEAN WELL SP-150 Series 150W Single Output with PFC Function
01

MEAN WELL SP-150 Series 150W Single Output with PFC Function
03 Terminal Pin No. Assignment

Pin No.

| Assignment| Pin No.|

Assignment

---|---|---|---

1

| AC/L| 4,5| DC OUTPUT -V
2| AC/N| 6,7|

DC OUTPUT +V

3

|

FG

| | | |

Remote ON/OFF(CN1):JST S2B-XH or equivalent(optional)

Pin No. Assignment Mating Housing Terminal

1

| RC+| JST XHP or equivalent|

JST SXH-001T-P0.6 or equivalent

2

|

RC-

Block Diagram

MEAN WELL SP-150 Series 150W Single Output with PFC Function
04

Derating Curve

MEAN WELL SP-150 Series 150W Single Output with PFC Function
05

Output Derating VS Input Voltage

Documents / Resources

| MEAN WELL SP-150 Series 150W Single Output with PFC Function [pdf] Instruction Manual
SP-150 Series 150W Single Output with PFC Function, SP-150 Series, 150W Single Output with PFC Function
---|---

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

MEAN WELL User Manuals

Related Manuals