PPI OmniX BTC Open Frame Dual Set Point Temperature Controller Instruction Manual

June 11, 2024
PPI

Open Frame Dual Set Point Temperature Controller
Instruction Manual

This brief manual is primarily meant for quick reference to wiring connections and parameter searching. For more details on operation and application; please log on to www.ppiindia.net
INPUT / OUTPUT CONFIGURATION PARAMETERS

Parameters Settings (Default Value)
Input Type Refer Table 1 (Default : Type K)

Control Logic ![PPI OmniX BTC Open Frame Dual Set Point Temperature Controller

  • icon 1](https://manuals.plus/wp-content/uploads/2023/05/PPI-OmniX-BTC-Open- Frame-Dual-Set-Point-Temperature-Controller-icon-1.jpg)| Reverse Direct (Default :Reverse )
    Setpoint Low | Min. Range to Setpoint High for the selected Input type (Default : Min. Range for the ) Selected Input Type
    Setpoint High | Setpoint Low to ax. Range M for the selected Input type (Default : Max. Range for the Selected input ) Selected Input Type
    Offset For PV ![PPI OmniX BTC Open Frame Dual Set Point Temperature Controller
  • icon 4](https://manuals.plus/wp-content/uploads/2023/05/PPI-OmniX-BTC-Open- Frame-Dual-Set-Point-Temperature-Controller-icon-4.jpg)| -1999 to 9999 or -199.9 to 999.9 (Default : 0)
    Digital Filter For PV| 0.5 to 25.0 Seconds (in steps of 0.5 Seconds) (Default : 1.0)
    Control Output TypePPI OmniX BTC Open Frame Dual Set Point Temperature
Controller - icon 5| Relay (Default) SSR
    Output-2 Function Selection| (Default) None Alarm Control Blower Soak Start Output
    Output 2 Type | Relay (Default) SSR

CONTROL PARAMETERS

Parameters Settings (Default Value)
Control Mode (Default) On-Off PID
On-Off Hysteresis 1 to 999 or 0.1 to 99.9 (Default : 2 or 0.2)
Compressor Time Delay 0 to 600 Sec. (in steps of 0.5 Sec.) (Default : 0)
Cycle Time 0.5 to 120.0 Seconds (in steps of 0.5 Seconds) (Default : 20.0

Sec)
Proportional Band | 0.1 to 999.9 (Default : 10.0)
---|---
Integral Time | 0 to 1000 Seconds (Default : 100 Sec)
Derivative Time | 0 to 250 Seconds (Default : 25 Sec)

OUTPUT-2 FUNCTION PARAMETERS

OP2 Function : Alarm

Parameters Settings (Default Value)
Alarm Type Process Low Process High Deviation Band Window Band End of Soak

(Default : Process Low)
Alarm Inhibit ![PPI OmniX BTC Open Frame Dual Set Point Temperature Controller

OP2 Function : Control

Parameters Settings (Default Value)
Hysteresis 1 to 999 or 0.1 to 99.9 (Default : 2 or 0.2)
Control Logic Normal Reverse (Default : Normal)

OP2 Function : Blower

Parameters Settings (Default Value)
Blower / Compressor Hysteresis 1 to 250 or 0.1 to 25.0 (Default : 2 or 0.2)
Blower / Compressor Time Delay 0 to 600 Sec. (in steps of 0.5 Sec.) (Default

: 0)

SUPERVISORY PARAMETERS

Parameters Settings (Default Value)
Self-tune Command Yes No (Default : No)
Overshoot Inhibit Enable / Disable Disable Enable (Default : Disable)
Overshoot Inhibit Factor (Default : 1.2) 1.0 to 2.0
Setpoint Editing Permission on Operator Page Disable Enable (Default :

Enable)
Soak Abort Command on Operator Page | Disable Enable (Default : Enable)
Soak Time Adjustment on Operator Page | Disable Enable (Default : Enable)

OPERATOR PARAMETERS

OP2 Function : Alarm

Parameters x Settings (Default Value)
Soak Start Command  No Yes (Default : No)
Soak Abort Command No Yes (Default : No)
Soak Time 00.05 to 60.00 M:S or 00.05 to 99.55 H:M or 1 to 999 Hours

(Default : 3 or 0.3)
Alarm Setpoint  | Minimum to Maximum Range specified for the selected Input Type (Default : 0)
Parameters| Settings (Default Value)
---|---
Alarm Deviation  | -1999 to 9999 or -199.9 to 999.9 (Default : 3 or 0.3)
Alarm Band PPI OmniX BTC Open Frame Dual Set Point Temperature Controller -
icon 46| 3 to 999 or 0.3 to 99.9 (Default : 3 or 0.3)

OP2 Function : Control

Parameters Settings (Default Value)
Auxiliary Control Setpoint (Min. Range – SP) to (Max. Range – SP) (Default :

OP2 Function : Blower

Parameters Settings (Default Value)
Blower Control Setpoint  0.0 to 25.0 (Default : 0)

Control Setpoint (SP) Locking

Parameters Settings (Default Value)
 Setpoint Locking Yes No (Default : No)

SOAK TIMER PARAMETERS

Parameters Settings (Default Value)
Soak Timer Enable No Yes (Default : No)
Time Units  Manse Hours: Min Hours (Default : Min: Sec)
Soak Time 00.05 to 60:00 Manse 00.05 to 99:55 Hrs: Min 1 to 999 Hours

(Default : 00.10 Manse)
Soak start Band | 0 to 9999 or 0.0 to 999.9 (Default : 5 or 0.5)
Holdback Strategy PPI OmniX BTC Open Frame Dual Set Point Temperature
Controller - icon 55| None Up Down Both (Default : None)
Parameters| Settings (Default Value)
---|---
Hold Band | 1 to 9999 or 0.1 to 999.9 (Default : 5 or 0.5)
Switch-off Control Output At Timer End | No Yes (Default : No)
Power-fail Recovery Method | Continue (Re)Start Abort (Default : Continue)
Option| What it means| Range  (Min. to Max.)| Resolution
---|---|---|---
| Type J Thermocouple| 0 to+960°C| 1
PPI OmniX BTC Open Frame Dual Set Point Temperature Controller - icon
65| Type K Thermocouple| -200 to+1375°C| 1
| 3-wire, RTD Pt100| -199 to+600°C| 1
PPI OmniX BTC Open Frame Dual Set Point Temperature Controller - icon
67| 3-wire, RTD Pt100   –| -199.9 to+600.0°C| 0.1

FRONT PANEL LAYOUT

Display Board
Small Display Version

0.39” height, 4 Digit, Upper Row
0.39” height, 4 Digit, Lower Row Large Display Version
0.80” height, 4 Digit, Upper Row
0.56” height, 4 Digit, Lower RowPPI OmniX BTC Open Frame Dual Set Point
Temperature Controller - Display Board 1 Control Board LayoutPPI OmniX BTC
Open Frame Dual Set Point Temperature Controller -
Layout Keys Operation

Symbol Key Function
PAGE Press to enter or exit set-up mode.
DOWN Press to decrease the parameter value Pressing once decreases the

value by one count; holding pressed speeds up the change.
| UP| Press to increase the parameter value Pressing once increases the value by one count; holding pressed speeds up the change.
| ENTER| Press to store the set parameter value and to scroll
to the next parameter on the PAGE.

PV Error Indications

Message PV Error Type
Over-range (PV above Max. Range)
Under-range (PV below Min. Range)
Open (Thermocouple / RTD broken)

ELECTRICAL CONNECTIONSPPI OmniX BTC Open Frame Dual Set Point
Temperature Controller - ELECTRICAL CONNECTIONS

101, Diamond Industrial Estate, Namghar,
Vasai Road (E), Dist. Palghar – 401 210.
Sales : 8208199048 / 8208141446
Support : 07498799226 / 08767395333
E: sales@ppiindia.net,
support@ppiindia.net

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals