The Linearised Single Point Temperature Indicator is a device that displays temperature readings and provides alarm notifications when the temperature exceeds certain setpoints. The device has several operator parameters, including Alarm-1 and Alarm-2 setpoints, PV MIN/MAX parameters, Input Configuration Parameters, and Alarm Parameters. It also has a front panel layout that includes a process value display, alarm indicators, and various keys for operation. The device can accept different input types, including RTD Pt100, Type J, Type K, Type R, and Type S.

Product Usage Instructions

To use the Linearised Single Point Temperature Indicator, follow these steps:

  1. Connect the device according to the Electrical Connections diagram provided in the user manual.
  2. Turn on the device’s AC supply.
  3. Use the UP and DOWN keys to select the desired input type and temperature range on PAGE-12.
  4. Set the Alarm-1 and Alarm-2 setpoints on PAGE-0.
  5. Set the maximum and minimum process values on PAGE-1.
  6. Set the alarm type and hysteresis on PAGE-11.
  7. Press and hold the PROGRAM key for approximately 5 seconds to enter or exit setup mode.
  8. Use the UP and DOWN keys to adjust parameter values as needed.
  9. Monitor the process value display and alarm indicators for temperature readings and notifications.

Note : For relay output, connect LCR to the contactor coil for suppressing noises as shown in the LCR Connection to Contactor Coil diagram provided in the user manual.

OPERATOR PARAMETERS

PPI-IndeX-Linearised-Single-Point-Temperature-
Indicator-fig- \(1\)

PV MIN / MAX PARAMETERSPPI-IndeX-Linearised-Single-Point-Temperature-
Indicator-fig- \(2\) INPUT CONFIGURATION PARAMETERSPPI-IndeX-Linearised-Single-Point-Temperature-
Indicator-fig- \(3\)

ALARM PARAMETERSPPI-IndeX-Linearised-Single-Point-Temperature-Indicator-
fig- \(4\)PPI-IndeX-
Linearised-Single-Point-Temperature-Indicator-fig- \(5\)

FRONT PANEL LAYOUT

PPI-IndeX-Linearised-Single-Point-Temperature-
Indicator-fig- \(6\)PPI-IndeX-
Linearised-Single-Point-Temperature-Indicator-fig- \(7\)

ELECTRICAL CONNECTIONS

PPI-IndeX-Linearised-Single-Point-Temperature-
Indicator-fig- \(8\) PPI-IndeX-
Linearised-Single-Point-Temperature-Indicator-fig- \(9\) PPI-IndeX-Linearised-Single-Point-Temperature-
Indicator-fig- \(10\) PPI-IndeX-
Linearised-Single-Point-Temperature-Indicator-fig-
\(11\)

NOTE :- FOR RELAY OUTPUT ONLY LCR is to be connected to contactor coil for suppressing noises. (Refer LCR connection Diagram given below)

LCR CONNECTION TO CONTACTOR COIL

PPI-IndeX-Linearised-Single-Point-
Temperature-Indicator-fig- \(12\)