i3 INTERNATIONAL UIO8 v2 Universal Input Output Device User Manual
- June 11, 2024
- i3 INTERNATIONAL
Table of Contents
- UIO8 v2 Universal Input Output Device
- Precautions
- Default Connection Information
- Changing IP Address in ACT
- Wiring Diagram
- LED Status
- Adding UIO8v2 device to SRX-Pro
- Turning UIO8v2 Controls ON/OFF in Video Pilot Client (VPC)
- Troubleshooting
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Universal InputOutput Device
UIO8 v2
User Manual
UIO8 v2 Universal Input Output Device
Thank you for purchasing an i3 UIO8v2 LAN Inputs and Output Peripheral Device.
UIO8v2 has been designed to support two different functions: a single-reader
card access controller board or a universal I/O controller with 4 inputs & 4
outputs.
When used as an I/O Controller device, i3’s UIO8v2 may be integrated with the
i3’s SRX-Pro DVR/NVR system via LAN. SRX-Pro Server will detect and connect to
all UIO8v2 devices connected to Local Area Network. Each UIO8 device supports
4 inputs and 4 outputs and can control PTZ cameras through the TCP/IP
(network). SRX-Pro Server can connect to a total of 16 individual UIO8v2
devices supporting up to a maximum of 64 inputs and 64 outputs.
UIO8v2 can be powered with a 24VAC power source or via PoE Switch on the
network. UIO8v2 device, in turn, offers a 12VDC output, to power other
connected devices such as strobe light, buzzer, alarm etc., making for a more
convenient and cost-efficient installation. UIO8v2 may also be integrated with
i3’s CMS sensor input, which adds further reporting and monitoring
capabilities to i3 International’s CMS Site Info module and Alert Centre
application.
If the system needs to be modified or repaired, contact a certified i3
International Dealer/Installer. When serviced by unauthorized technician, the
system warranty will be voided. Should you have any problems or questions
regarding our products, contact your local Dealer/Installer.
Precautions
Installation and serving should be performed only by qualified and experienced
technicians to conform to all local codes and to maintain your warranty.
When installing your UIO8v2 device be sure to avoid:
- excessive heat, such as direct sunlight or heating appliances
- contaminants such as dust and smoke
- strong magnetic fields
- sources of powerful electromagnetic radiation such as radios or TV transmitters
- moisture and humidity
Default Connection Information
Default IP Address | 192.168.0.8 |
---|---|
Default subnet mask | 255.255.255.0 |
Control Port | 230 |
HTTP Port | 80 |
Default Login | i3admin |
Default Password | i3admin |
Changing IP Address in ACT
UIO8v2 devices cannot share an IP address, each UIO8v2 requires its own unique IP address.
-
Connect your UIO8v2 device to the Gigabit switch.
-
On your i3 NVR, launch i3 Annexes Configuration Tool (ACT) v.1.9.2.8 or higher.
Download and install the latest ACT installation package from i3 website: https://i3international.com/download -
Select “ANNEXXUS UIO8” in the model drop-down menu to show only the UIO8v2 devices in the list.
-
Enter the new IP address and Subnet Mask of the UIO8v2 in the Device(s) Communication Update area.
-
Click Update and then Yes in the confirmation window.
Tip: New IP address must match the IP range of LAN or NVR’s NIC1. -
Wait a few moments for a “Success” message in the Result field.
Repeat Steps 1-5 for all detected UIO8v2 devices OR -
Assign IP range to multiple devices by selecting two or more UIO8v2 in ACT, then entering the starting IP address and the final IP octet for your IP range. Click Update and then Yes in the confirmation window. Wait until “Success” message is shown for all selected UIO8.
Wiring Diagram
LED Status
-
POWER (Green LED): indicates power connection to UIO8v2 device.
-
RS485 TX-RX: indicates signal transmission to and from connected devices.
-
Portal / IO (Blue LED): indicates current function of the UIO8v2 device.
LED ON – Portal Card Access; LED OFF – IO Control -
SYSTEM (Green LED): blinking LED indicates the health of the UIO8v2 device.
-
FIRMWARE (Orange LED): blinking LED indicates firmware upgrade in progress.
Scan this QR code or visit
ftp.i3international.com for a complete range
of i3 product quick guides and manuals.
Contact our Technical Support team at: 1.877.877.7241 or
support@i3international.com if you have
any questions or concerns regarding device installation or if you require
software services or support.
Adding UIO8v2 device to SRX-Pro
-
Launch the i3 SRX-Pro Setup from the Desktop or from the SRX-Pro Monitor.
-
In the IE browser, click Continue to this website.
-
Enter your administrator Username and Password and click LOGIN .
Tip: default administrative login is i3admin. -
Click on the Server tile > I/O devices > Controls (0) or Sensors (0) tab
-
Click SEARCH UIO8 button.
All UIO8v2 devices on the network will be detected and displayed. -
Select the desired UIO8v2 device(s) and click ADD.
In this example, UIO8v2 device with the IP Address 192.168.0.8 has been selected. -
Four (4) Control Outputs and four (4) Sensor Inputs from each selected UIO8v2 device will be added to I/O devices tab.
-
Configure settings for connected controls and sensors and click Save .
https://www.youtube.com/channel/UCqcWka-rZR-CLpil84UxXnA/playlists
Turning UIO8v2 Controls ON/OFF in Video Pilot Client (VPC)
To turn the Control outputs ON/OFF remotely, launch Video Pilot Client
software. Connect to the localhost server if running VPC on the same NVR.
Otherwise, add new server connection and click Connect.
In LIVE mode, hover the mouse over the bottom of the screen to reveal the
Sensor/Control menu panel.
Turn individual controls ON and OFF by clicking on the corresponding control
button.
Hover over the Control button to see the Control custom name.
Troubleshooting
Q: Some UIO8v2 devices cannot be found in SRX-Pro.
A: Make sure each UIO8v2 device has a unique IP address. Use Annexes
Configuration
Tool (ACT) to change IP address for all UIO8v2 devices.
Q: Unable to add UIO8 to SRX-Pro.
A: UIO8v2 device can be used by a single application/service at-a-time.
Example: If i3Ai Server is using UIO8v2 device, then SRX-Pro running on the
same NVR will not be able to add the same UIO8v2 device. Remove the UIO8v2
from the other application before adding to SRX-Pro.
In SRX-Pro v7, UIO8v2 devices already in use by another application/service
will be grayed out. The IP of the device running the application currently
using the specific UIO8v2 device will be visible in Used by column.
In this example, UIO8v2 with the IP address 102.0.0.108 is grayed out and
cannot be added as it’s currently in use by the application running on the
device with the IP address 192.0.0.252.
REGULATORY NOTICES (FCC CLASS A)
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
RADIO AND TELEVISION INTERFERENCE
This equipment has been tested and found to comply with the limits of a Class
A digital device, pursuant to Part 15 of the FCC rules. These limits are
designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful
interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the
interference at his own expense.
This Class A digital apparatus complies with Canadian ICES-003.
i3 INTERNATIONAL INC.
Tel: 1.866.840.0004
www.i3international.com
References
- i3 International FTP Login Page
- Ai Smart Video & Cloud Solutions | i3 International
- Download - i3 International
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>