Sea Gull Lighting 98745S DC Single Feed 60W Remote Electronic Transformer Instruction Manual
- June 9, 2024
- Sea Gull Lighting
Table of Contents
Sea Gull Lighting 98745S DC Single Feed 60W Remote Electronic Transformer
GENERAL PRODUCT INFORMATION
- This transformer is safety listed for use with low voltage lighting systems offered by Ambiance Lighting.
- This product is safety listed only for indoor dry locations and approved for use at any height above the finished floor.
- A typical installation is shown. Specific installation must be in accordance with the local electrical codes.
- This product may be dimmed only with a low voltage electronic dimmer.
- Using a dimmer not designed for low voltage electronic applications may work initially, but could eventually cause transformer failure and will void the warranty.
- The dimmer must be derated as indicated by the dimmer manufacturer.
- During installation, make sure all power connections are tight.
- Read all instructions thoroughly. Read “Important Safety Information” on next column before proceeding with the installation.
Important Safety Information
- Do not conceal or extend bus bar conductors through a building wall.
- To reduce the risk of fire and burns, do not install this lighting system where the uninsulated open bus bar conductors can be shorted or contact any conductive materials.
- To reduce the risk of the system overheating and possibly causing a fire, make sure all the connections are tight.
- Do not install fixture assemblies closer than six inches to curtains or similarly combustible materials.
- Turn the electrical power off before modifying the lighting system in any way.
- The fixtures used with the system must be identified for use with the corresponding system.
- To Reduce Risk of Fire, it is important to wire the remote transformer for the system as described in this installation instruction.
- The circuit of the remote transformer is rated at a MAXIMUM of 60 Watts. Do not exceed.
Install the Remote Transformer
- Remove the four Phillips screws to remove the transformer cover.
- Secure the transformer housing in place (hardware not included).
- Install conduit and power line wires from the panel to the remote transformer.
- Do not connect the power line wires to the panel at this time.
- Make sure the transformer housing is grounded in accordance with local electrical codes.
- Connect the transformer white wire to the neutral power line wire with a wire nut.
- Connect the transformer black wire to the hot power line wire with a wire nut.
- Feed the connector wires through the transformer.
- Connect the black transformer wire to the black connector wires with a wire nut.
- Connect the red transformer wire to the red connector wires with a wire nut.
- Connect the 120 volt power line wires at the panel.
- After installing the entire system, operate the system for five minutes. On the low voltage side, all electrical connection points should be no more than warm to the touch. If a connection is hot to the touch, retighten the connection and check to ensure that the temperature decreases.
- Replace the transformer cover and tighten the four Phillips screws.
Warranty
Sea Gull Lighting fixtures and components, when properly installed and under normal conditions of use, are warranted to be free from defects in materials and workmanship for one year from date of sale. LED light sources are warranted for five years. ENERGY STAR® labeled products are warranted for three years. Sea Gull Lighting at its sole option will repair or replace, F.O.B. Factory, freight prepaid, any Sea Gull Lighting product defective in materials or workmanship. Such replacement is the exclusive remedy against Sea Gull Lighting should any of the products delivered prove defective. Invoices for labor charges and/or chargebacks for labor will be denied unless prior written approval is given. Any modification to a Sea Gull Lighting product not made at the factory will void the UL or ETL listing as well as the Sea Gull Lighting warranty policy.
To register your fixture, please visit our website: SeaGullLighting.com
CAUTION: RISK OF FIRE
This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved. Use minimum 90°c supply conductors.
SAVE THESE INSTRUCTIONS!
NEED HELP?
Please do not return this product to the store.
If you need installation assistance, or replacement parts, or have questions regarding our warranty, please call our customer care center: 1-800-347-5483
To register your fixture, please visit our website: www.SeaGullLighting.com
- 7400 Linder Ave, Skokie, IL 60077
- 847.410.4400
- www.SeaGullLighting.com
© 2015 Ambiance, L.L.C. All rights reserved. The “Ambiance” graphic is a registered trademark of Sea Gull Lighting, L.L.C. Sea Gull Lighting reserves the right to change specifications for product improvements without notification.
A Generation Brands Company
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>