Blue-White F-450 Flow Meter Instruction Manual
- July 3, 2024
- Blue-White
Table of Contents
Blue-White F-450 Flow Meter
Specifications
Engineering Specifications
Flow Meter Specifications
- Maximum Working Pressure : 175 PSI (12 bar)
- Maximum Fluid Temperature : 212°F (100°C)
Materials of Construction
Wetted Components:
- Meter Body: PTFE
- Adapters: 316ss
- Guide Rod Holder : 316ss
- O-ring Seals: 316ss
- Float Guide Rod: 316ss
Temperature vs. Pressure Graph
(Graph details not provided in this manual)
Flow Specifications
Output Specifications:
Model | Feed Rate GPM | Max Pressure PSI (bar) | Float Material |
---|---|---|---|
F-45375L | N/A | 175 (12) | PTFE |
Dimensions
- Model No. A B C D
- F-45375L N/A N/A In-line
- F-45376L 8-7/8 (225.5mm) 1-3/4 (44.4mm) N/A N/A In-line
Product Usage Instructions
Installation
Installation Requirements
Before beginning installation, review your system flow and pressure to ensure
your F-450 is proper for your system parameters.
Tools Required
- Standard plumbing tools
- Teflon tape or pipe sealant
- Adjustable wrench
- Pipe cutter (if necessary)
Installation Instructions
- Turn off the water supply to the system where you will install the flow meter.
- Choose an appropriate location for installation, ensuring proper alignment with the flow direction.
- Use the provided adapters to connect the flow meter in line with the existing plumbing.
- Secure all connections tightly using the appropriate tools.
- Turn on the water supply and check for any leaks. Adjust connections if necessary.
FAQ
Q: Can the F-450 Flow Meter be used for chemicals other than water?
A: While it may be suitable for other chemicals, Blue-White cannot guarantee
their suitability. It is recommended to test and calibrate for water only.
Q: What should I do if I encounter issues with my F-450 Flow Meter?
A: Refer to the Maintenance and Troubleshooting section of the manual for
guidance on resolving common issues. If problems persist, contact customer
service for assistance.