Westinghouse WGEN7500DFC 7500 Watt Electric Start Dual Fuel Portable Generator User Guide
- June 4, 2024
- Westinghouse
Table of Contents
Westinghouse WGEN7500DFC 7500 Watt Electric Start Dual Fuel Portable
Generator
BEFORE STARTING
-
Install feet to frame.
- Tip the generator onto the muffler side.
- Install the mounting feet to the frame using M8 flange bolts.
-
Install wheels
-
* Install the axle pin, wheel and washer through the axle bracket on the frame.
- Install the hairpin cotter through the axle pin to lock it in place.
-
-
Add engine oil.
- Remove oil fill plug/dipstick
- Using the supplied 4-cycle engine oil and funnel, slowly add engine oil to the engine until full.
- Replace oil fill plug/dipstick.
-
Add unleaded gasoline to gas tank.
- Unscrew gas cap on top of tank and insert a clean funnel into the tank.
- Slowly add gasoline into the fuel tank. The gasoline level should NOT be higher than the filler neck.
- Secure gas cap.
-
Hook up LPG tank.
- Connect included LPG hose to standard LPG tank and hand tighten.
- Connect other end of LPG hose to regulator on generator and hand tighten.
- Test connections with soapy water to make sure there are no leaks.
STARTING PROCEDURE
-
Make sure the generator is OUTSIDE in a well ventilated dry area and FAR AWAY from any doors, windows, or vents.
-
Check oil and fuel levels.
-
Make sure nothing is plugged into power outlets.
-
Connect battery
-
Make sure the circuit breakers are properly set to operating.
-
Choose fuel source:
- If starting with Gasoline: Turn fuel selector switch to the gasoline position. Move the fuel valve to the ON position.
- If starting with Propane: Turn fuel selector switch to the propane position. Open propane tank valve.
-
Switch the engine switch to RUN
-
Choose starting method:
-
Push-Button Start: Hold for 1 second and release when engine starts.
-
Wireless Remote Start: Hold Start button on wireless remote for 1 second and release
-
Manual Start: Manually set choke. Pull recoil handle slowly until you feel resistance, then apply rapid pull up and away from generator
-
-
Plug in electronic devices.
MAINTENANCE SCHEDULE
Following the maintenance schedule is important to keep the generator in good
operating condition. The following is a summary of maintenance items by
periodic maintenance intervals.
Refer to the Maintenance section in the Owners Manual to find out how to
properly perform maintenance.
Maintenance Item
| Before Every Use
| After First 25 Hours or First Month of Use
| After 50 Hours of Use or Every 6 Months
| After 100 Hour of Use or Every 6 Months
| After 300 Hours of Use or Every Year
---|---|---|---|---|---
Engine Oil
| Check Level
| Change1| Change
| –| –
Air Filter| –| –| Clean2
| –| Replace
Spark Plug| –| –| –| Check/Clean| Replace
Spark Arrestor| –| –| –| Check/Clean| –
Fuel Filter| –| –| –| Replace3| –
Valve Clearance| –| –| –| Inspect/Adjust3| –
- Change oil every month when operating under heavy load or in high temperatures.
- Clean more often under dirty or dusty conditions.
- Recommended service by authorized Westinghouse dealer.
ENGINE OIL
Only use 4-stroke/cycle engine oil. NEVER USE 2-STROKE/CYCLE OIL.
Synthetic oil is an acceptable substitute for conventional oil.
DANGER: Using a generator indoors
CAN KILL YOU IN MINUTES.
Generator exhaust contains carbon monoxide. This is a poison you cannot see or
smell.
- NEVER use inside Only use OUTSIDE a home or garage, even if door and windows are open.
- Only use outside and far away from window, door, and vents.
Avoid other generator hazards.
READ MANUAL BEFORE USE.
Documents / Resources
|
Westinghouse WGEN7500DFC 7500 Watt Electric Start Dual Fuel Portable
Generator
[pdf] User Guide
WGEN7500DFC, 7500 Watt Electric Start Dual Fuel Portable Generator,
WGEN7500DFC 7500 Watt Electric Start Dual Fuel Portable Generator
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>