Product Information
The DALI AC Switch ModelNo.:DH is a product that provides two DALI addresses and two-channel AC output. It comes with a numeric display and LVD features. The product is designed to cater to unwanted dimming lighting systems and can be used to switch two LED lamps, traditional incandescent and halogen lights. The switching thresholds of the relay can be set on the DALI bus, and it also has a zero-cross-switching function. The product is compliant with DALI products from other international incorporation and follows the DALI standard protocol IEC 62386-102, and IEC 62386-208.
Technical Parameters
- B: AC100-240V
- Output voltage: AC100-240V
- Output current : 2CH, 5A Max
- Output power: 2*(500-1200)W
- Operation temperature: Ta: – 30 OC ~ +55 OC
- Case temperature (Max.): T c: +70OC
- IP rating: IP20
- Warranty: 5 years
- Weight: 123g
- Gross weight: 140g
Mechanical Structures and Installations
The product has an AC N input and output, AC L input, and two AC L outputs. It also has two groups of DALI signal inputs, a digital display, and a setting key. The wiring diagram should be carefully followed.
Product Usage Instructions
- Relay switch setting: To toggle Relay Switch on and off, long-press two buttons at the same time for 2s. The default setting is on. To turn on, short press the setting 1 key, and to turn off, short press the setting 2 key. Long press any of the two buttons for 2s or timeout 10s to quit Relay switch setting.
- Set DALI Address via buttons: To set the start DALI address, long-press any of the two buttons for 2s, and the digital display starts flashing. To set the tens position, short press the first button, and to set the units position, press the second button. The address can be set from 00~62-FF. If no DALI address is assigned for the dimmer, the digital display shows FF. Address assignments are sequential. If the set address value is 01, the CH1 address value is 01, and the CH2 address value is 02.
- Note: If output is connected with capacitive or inductive load, the maximum output current is only up to 5A. If output is connected with resistive load, the maximum output current may be up to 8A. Please ensure all wire connections and polarities are correct and secure before applying power; otherwise, this controller will be damaged.
Features
- DALI control power on/off to cater for unwanted dimming lighting system, two DALI addresses, two-channel output, AC input, and AC output.
- In accordance with DALI standard protocol IEC 62386-102, IEC 62386-208 and in compliance with DALI products from other international incorporation.
- DALI address can be manually assigned and shown in digital display or automatically assigned by the DALI master.
- The switching thresholds of the relay can be set on the DALI bus
- Zero cross switching function, 2 independently output channels AC switch.
- To switch two LED lamps, traditional incandescent and halogen lights.
Technical Parameters
Input and Output
Input voltage| AC100-240V
Output voltage| AC100-240V
Output current| 2CH, 5A Max
Output power| 2*(500-1200)W
Environment
Operation temperature| Ta: -30 O C ~ +55 O C
Case temperature (Max.)| T c: +70O C
IP rating| IP20
Mechanical Structures and Installations
Wiring Diagram
Caution:
Please carefully ensure all wire connections and polarities are correct and secure before applying power, otherwise, this controller will be damaged .
Note:
If output connects with a capacitive or inductive load, the maximum output
current only up to 5A. If output connect with resistive load, the maximum
output current may up to 8A.
Operation
Relay switch setting
- Long press two buttons at the same time for 2s, Toggle Relay Switch: On(”On”) and Off(”OF”).
- Enter the default setting to on(”On”), then short press the setting 1 key to turn on(”On”), short press the setting 2 key to turn off(”OF”).
- Long press any of the two buttons for 2s or timeout 10s, quit Relay switch setting.
Set DALI Address via buttons
- Long press any of the two buttons for 2s, prepare for set the start DALI address, and digital display start ashes.
- Short press Frst button to set the “tens” position and second button to set “units” position.
- The address can be set from 00~62-FF. no DALI address is assigned for the dimmer, digital display shows “FF”.
- Address assignments are sequential. If the set address value is 01, the CH1 address value is 01, and the CH2 address value is 02, The display shows the CH1 address value.
- Long press any of the two buttons for 2s or timeout 10s, quit start DALI address setting, digital display stop ashes.
DALI address assigned by DALI masters
- DALI address can also be assigned by DALI Master controller automatically.
- Please refer to user manuals of compatible DALI Masters for specic operations.
- The digital display will show “AU” When the DALI master is assigning address.
- After address is assigned, the digital display will show the start DALI address”xx”, xx is from 00 to 63.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>