SKYDANCE S1-B+R11 AC Triac RF plus Push Dimmer Kit Owner’s Manual

June 8, 2024
SKYDANCE

AC Triac RF + Push Dimmer Kit

Model No.: S1-B+R11

RF dimming/Leading edge or trailing edge/Min brightness settable/Push Dim/Wall junction box mounting

Features
  • RF + Push AC phase-cut dimmer, 1 channel output.
  • To dim and switch single color dimmable LED lamps, traditional incandescent and halogen lights.
  • Leading edge dimming or trailing edge dimming set by dip switch.
  • Min brightness can be set by key.
  • Light on/off fade time 3s selectable.
  • Connect with external push switch to achieve on/off and dimming function.
  • Easy to be inserted into standard 86*86mm wall box.
Technical Parameters

Triac Dimmer’s Input and Output

Input voltage| AC100-240V
Output voltage| AC100-240V
Output current| Max 1.5A
Output power | 150-360W
Dimming signal | RF 2.4GHz + Push Dim
Dimming level| 256 levels
Dimming range| 0 -100%

LED Remote’s Input and Output

Output signal | RF(2.4GHz)
Working voltage| 3VDC(CR2032)
Working current| <5mA
Standby current| <10μA
Standby time| <1 years
RF Control distance| 30m(Barrier-free space)

Safety and EMC

EMC standard (EMC)| ETSI EN 301 489-1 V2.2.3 ETSI EN 301 489-17 V3.2.4
Safety standard(LVD) | EN 62368-1:2020+A11:2020
Radio Equipment(RED)| ETSI EN 300 328 V2.2.2
Certication| CE,EMC,LVD,RED

Environment

Operation temperature| Ta: -30ºC ~ +55ºC

Mechanical Structures and Installations

SKYDANCE S1-B+R11 AC Triac RF plus Push Dimmer Kit A01

  1. AC Push switch
  2. Match / Min brightness set key
  3. DIP switch for Leading edge or trailing edge phase-cut select
  4. AC N output
  5. AC L output
  6. AC L input
  7. AC N input

Typical Wall Junction Box Mounting

Remote function

SKYDANCE S1-B+R11 AC Triac RF plus Push Dimmer Kit A03

  1. LED indicator
  2. On/Off
  3. 100%
  4. Bright touch slide
  5. 50%
  6. 1%
  7. Back holder with magnet
Compatible Load Types
Load Type Maximum Load Remarks
Dimmable LED lamps 200W @ 220V 100W @ 110V Due to variety of LED lamp

designs, maximum number of LED lamps is further dependent on power factor result when connected to dimmer.
Triac Dimmable LED drivers| 200W @ 220V 100W @ 110V| Maximum permitted number of drivers is 200W divided by driver nameplate power rating, and make sure the surge current is no more than 2 times 65A.
Incandescent lighting, HV Halogen lamps| 400W @ 220V 200W @ 110V|

Wiring diagram

Caution: Please carefully ensure all wire connections and polarities are correct and secure before applying power, otherwise this dimmer will be damaged.

SKYDANCE S1-B+R11 AC Triac RF plus Push Dimmer Kit A04

  1. Push Switch
  2. Dimmable LED light

Connect with dimmable LED light

  1. Push Switch
  2. Triac Dimmable
  3. LED Driver
  4. LED light

Connect with Triac dimmable LED driver

Note: When calculating the maximum number of load lamps or drivers, the input power or input current parameters of a single lamp or driver must be used, the output power parameters can not be used.
In addition, the maximum surge current of the dimmer is 65A, the sum of surge current of multiple dimmable LED drivers should not exceed 2 times. otherwise, the product will be overloaded and damaged.

Leading edge or trailing edge dimming setting

Select leading edge(forward-phase) dimmer or trailing edge(reverse-phase) dimmer according to dimmable LED light or driver.

Reverse-phase
Forward-phase

Caution: before power on, you must confirm the selection of dip switch.

Min brightness setting
Long press Min set key for 2s, the light blink 2 times, ready for min brightness set, then short press Min set key 1-6 times, to get 6 min brightness: 5%, 10%, 15%, 20%, 25% or 30%, the light will output the current min brightness immediately, Long press Min set key for 2s or wait 8s, quit min brightness set, the light will output 100% brightness automatically.

Light on/off fade time
Long press Match key 5s, then short press Match key 3 times, the light on/off time will be set to 3s, the indicator light blink 3 times. Light on/off fade time Long press Match key 10s, restore factory default parameter, the light on/off time also restore to 0.5s.

Match Remote Control (two match ways)
End user can choose the suitable match/delete ways. Two options are offered for selection:

Use the controller’s Match key Use Power Restart

Match:
Short press Match key, immediately press on/off key of the remote. | Match:
Switch off the power, then switch on power, repeat again.
Immediately short press on/off key 3 times on the remote.
The light blinks 3 times means match is successful.
Delete:
Press and hold Match key for 5s to delete all match,
The light blinks 5 times means all matched remotes were deleted.| Delete:
Switch off the power, then switch on power, repeat again.
Immediately short press on/off key 5 times on the remote.
The light blinks 5 times means all matched remotes were deleted.