signify FSS220L840-UNV-DIM Fluxstream LED Strip Instruction Manual

June 9, 2024
signify

signify logo

FSS220L840-UNV-DIM Fluxstream LED Strip

INSTALLATION INSTRUCTIONS
FLUXSTREAM LED STRIP
CAUTION: THE INSTALLATION AND SERVICING OF THIS PRODUCT SHOULD BE PERFORMED BY A QUALIFIED ELECTRICIAN OR SERVICE PERSONNEL

  1. Remove unit from carton and inspect to ensure no shipping damage has occurred.

  2. This luminaire is supplied with knockout holes for wiring access across the back of housing and side of each end cap.

  3. To install with HANGER BRACKETS (See FIG.1):
    A. Mount hanger brackets to structure with #8 screws. (Minimum 2 brackets per luminaire)
    B. Once mounting brackets are secured to surface, snap luminaire into brackets. Mounting bracket should be secured into reveal of luminaire. Tighten mounting bracket with #8-18 x 2″ bolt that is provided.
    C. Secure LED board to housing by looping tether over “T” lance as shown in Figure 2.
    D. For stand alone installation bring customer supply wires into luminaire though preferred knockout hole. Make electrical connection per electrical code.
    E. For continuous row mounting refer to “CONNECTING LUMINAIRES FOR ROW MOUNTING”: follow steps A, B and C above for each luminaire. A customer supplied chase nipple and lock nut should be inserted into the knockout hole on each end of the adjoining fixtures as shown in Fig 6.

  4. To install with optional chain/hanger kit (PURCHASED SEPARATELY): Remove the V-Hook and chains from the bag pack. Hook the V-Hook into each end of the luminaire in provided holes. The chains should then be attached to the permanent structure of the building.

  5. To install with cable/stem mounting assembly (PURCHASED SEPARATELY):
    A. Mount cable or stem to building structure above luminaire.
    B. Remove stem mount KOs shown in Fig 1 at each end of fixture
    C. Mount cable or stem to fixture in KO hole using included hardware.signify
FSS220L840 UNV DIM Fluxstream LED Strip

  6. Snap on LED board carrier by aligning screws in LED board carrier with notches in housing. Then pivot board carrier until opposite side snaps in as shown in Fig 3, making sure no wires are pinched between housing and board carrier.

  7. Snap on lens by angling one side in and then pivot the opposite end around to snap in the other side as shown in Fig 4.

CAUTION: This fixture is designed for permanent installation in ordinary (Non-Hazardous) locations in accordance with the National Electrical Code and all applicable local codes. Do not use in areas of limited ventilation or in high ambient enclosures. The lamp and fixture operate at high temperatures. Contact with combustible materials can cause fire and personal contact can cause severe burns.
FOR FIXTURE MAINTENANCE (ACCESSING WIRING COMPARTMENT)
To remove lens from housing, push side of lens until the opposite side of lens protrudes from housing. Then pull protruding lens downward until removed as shown in Figure 5. This should be applied down the length of the fixture. Squeezing both sides of the housing inward while pushing side of lens will help remove lens and LED board carrier. Once LED board carrier is removed from housing, the lens will need to be removed from LED board carrier by sliding it down the length of the LED board carrier.

CONNECTING LUMINAIRES FOR ROW MOUNTING

  1. Make sure each luminaire is secured to building structure, by at least two points, before process begins, do not use “endcap to endcap” connection for replacing cable, pendant or surface mounting options.
  2. Remove joining end caps and remove KOs. Secure the endcaps together with customer supplied (2) #8 screws and (1) 1/2″ chase nipple to create joiner as shown in FIG 6A. IF USING FSSJ- COUPLER ACCESSORY (SHOWN IN FIG 6B): Remove and dispose of joining endcaps.
  3. Slide joiner assembly or FSSJ coupler accessory into fixture. Slide in next luminaire into joiner assembly as shown in FIG 7A or FIG 7B for FSSJ accessory.signify FSS220L840 UNV DIM Fluxstream LED Strip - fig
  4. Install screws as shown in FIG 8 and make electrical conncetions inside luminaire in accordance with the National Code and local regulations. Refer to page 1 for installing the LED carrier and lens.signify FSS220L840 UNV DIM Fluxstream LED Strip - fig 1

CAUTION: This fixture is designed for permanent installation in ordinary (Non-Hazardous) locations in accordance with the National Electrical Code and all applicable local codes. Do not use in areas of limited ventilation or in high ambient enclosures. The lamp and fixture operate at high temperatures. Contact with combustible materials can cause fire and personal contact can cause severe burns.

Signify Corporation North
America
200 Franklin Square Drive
Somerset, NJ 08873
Phone: 855-486-2216
www.day-brite.com
Signify Canada Ltd./Signify
Canada Ltee. 281 Hillmount
Road Markham ON, Canada
L6C 2S3
Phone: 800-668-9008
www.cfi-lighting.com
12NC:442100256110 DB100233 10/09/2018