ELKO RFTC-50/G Autonomous Temperature Controller Instruction Manual

June 9, 2024
ELKO

ELKO RFTC-50/G Autonomous Temperature Controller

ELKO RFTC-50 G Autonomous Temperature Controller

Warning

Instruction manual is designated for mounting and also for user of the device. It is always a part of its packing. Installation and connection can be carried out only by a person with adequate professional qualification upon understanding this instruction manual and functions of the device, and while observing all valid regulations. Trouble-free function of the device also depends on transportation, storing and handling. In case you notice any sign of damage, deformation, malfunction or missing part, do not install this device and return it to its seller. It is necessary to treat this product and its parts as electronic waste after its lifetime is terminated. Before starting installation, make sure that all wires, connected parts or terminals are de-energized. While mounting and servicing observe safety regulations, norms, directives and professional, and export regulations for working with electrical devices. Do not touch parts of the device that are energized – life threat. Due to transmissivity of RF signal, observe correct location of RF components in a building where the installation is taking place. RF Control is designated only for mounting in interiors. Devices are not designated for installation into exteriors and humid spaces. The must not be installed into metal switchboards and into plastic switchboards with metal door – transmissivity of RF signal is then impossible, do not use in areas affected by high-frequency interference. RF Control is not recommended for pulleys etc. – radiofrequency signal can be shielded by an obstruction, interfered, battery of the transceiver can get fl at etc. and thus disable remote control.

Characteristics

  • the temperature controller RFTC-50/G is used as a simple solution for controlling temperature in a room or the home

  • the RFTC-50/G is a programmable temperature controller with the option of setting a weekly program, which offers two regulation options:
    a) the internal sensor scans the temperature, and based on the set command, it gives the command to switch on the switching actuator RFSA-6x, RFUS-61 or RFSC-61. This can be used mainly to control temperature of heaters, hall panels, convection heaters, etc.
    b) the internal sensor scans the temperature, and based on the set command (weekly program), it switches on the actuator RFSTI-11B, which also scans the critical fl oor temperature (this occurs to prevent damage when opening a window). This solution is especially suitable for underfl oor heating.

  • control is performed using buttons, individual symbols (temperature, battery, mode, etc.) are displayed on a backlit LCD display

  • the controller is powered by: batteries – 2 x AAA 1.5 V

  • the flat rear side of the device enables its placement anywhere in the room where you wish to measure temperature

  • the LOGUS90 frame design offers a luxurious design (glass, wood, stone, metal) with the option of placing it in multiple frames

ELKO EP declares that the RFTC-50/G type of radio equipment complies with Directive 2014/53 / EU. The full EU Declaration of Conformity is available at: www.elkoep.com/wireless-temperature-controller—rftc-50g

Technical parameters

  • Supply voltage:  2x 1.5 V AAA batteries
  • Battery life:  1 year based on frequency of use according to the number of controlling actuators
  • Temperature correction:  2 buttons ^/ ^
  • Temperature offset:  ± 5 °C
  • Display:  LCD, characters / see Display description
  • Backlighting:  active 10 s after pressing
  • Transmission indication/ function:  symbols
  • Temperature measurement:  1x internal sensor
  • Temp. measurement range and accuracy:  0 to +55 °C; 0.3 °C of the range

Control

  • Communication protocol:  RFIO
  • Frequency: 866–922 MHz
  • Repeater function: no
  • Signal transmission method:  bidirectionally addressed message
  • Range:  in open space up to 100 m
  • Minimum control distance:  20 mm

Other data

  • Max. number of control.  RFSA-6x: 4
  • Program:  Weekly
  • Operating temperature:  0 to + 55 °C
  • Operating position:  on the wall
  • Mounting: by gluing/screwing
  • Protection: IP30
  • Contamination degree:  2

Dimensions frame

  • plastic:  85 x 85 x 20 mm
  • metal, glass, wood, granite:  94 x 94 x 20 mm
  • Weight:  66 g (without batteries)
  • Related standards:  EN 60669, EN 300 220, EN 301 489 directive R&TTE Directive, Order. No 426/2000 Coll. (Directive 1999/EC)

Battery replacement

Prior to first assembly, remove the moldings in the frame and peel off the protective film from the display.
After inserting the batteries, all features for controlling the display function illuminate for 2 seconds, then the FW version is displayed in the upper row.

ELKO RFTC-50 G Autonomous Temperature Controller 1

Placement

Do not expose it to sharp temperature changes, direct sunlight or excessive moisture. Place the temperature units so that they are not near windows or heating equipment, etc., which could influence the internal temperature sensor.

Attention:
When you install iNELS RF Control system, you have to keep minimal distance 1 cm between each units.
Between the individual commands must be an interval of at least 1s.

ELKO RFTC-50 G Autonomous Temperature Controller 2

Description of device

ELKO RFTC-50 G Autonomous Temperature Controller 3

Description of display

ELKO RFTC-50 G Autonomous Temperature Controller 4

setting the time
locking the menu item or program
manual mode
setting the temperature
output switched on when selecting heating function
output switched on when selecting cooling function
displays in the case of low battery voltage
vacation mode
constantly illuminated – connection with all actuators successful
flashing – connection successful only with certain actuators
not illuminated – connection unsuccessful with all actuators

Battery status indicator:
A symbol is displayed when the batteries are running low. The dead battery indicator shows that the voltage is insufficient for reliable communication with a paired actuator(s).

Description of control

Button functions for controlling:

  • Short press of buttons ^ ^ (< 2 s)
  • switching menu items, changing value

Long button press ^ ( > 2 s)

  • unlocking the menu item or time program for changing
  • confirmation of changed value after setting and locking of the menu item or program

Long button press ^ ( > 2 s)
refusal of changed value, return to original value and locking of the menu item or program

Short press of hidden button ( < 2 s)

  • closing menu – after closing the menu communication with actuators is performed
  • the default display indicates the update of the actuator status (e.g. upon actuator power failure)

Long press of hidden button ( > 2 s)
upon default display entry to the menu

ELKO RFTC-50 G Autonomous Temperature Controller 6

Selecting the heating mode

ELKO RFTC-50 G Autonomous Temperature Controller 7

At the default display, press and hold the button ^ . In the upper row of the display, the indicator rEG appears and the symbol of the currently chosen heating mode fl ashes, or the indicator OFF appears. Now by shortly pressing the buttons ^ ^ you can select the heating mode. Confirm the heating mode selection by pressing and holding the button ^ .
You can return to the original mode by pressing and holding . This also brings you to the initial display.

Setting the temperature for manual mode

At the default display, briefly press the button ^ or ^ . In the upper row, the indication t °C is displayed and in the lower row the current selected temperature flashes.

By short presses of the buttons ^ ^ , you will change the value by an increment of 0.5 °C.
By pressing and holding the buttons ^/^, you begin accelerated setting of the value.
After completing the settings, after 5 seconds it automatically returns to the initial display, thereby confirming the temperature change. It also assesses the current and required temperatures and communicates with the actuator(s).

Entering the programming menu

ELKO RFTC-50 G Autonomous Temperature Controller 9

ELKO RFTC-50 G Autonomous Temperature Controller 10

  • only possible from the default display by pressing and holding the hidden button
  • the display indicates ProG
  • by short presses of the buttons ^ ^ , you can toggle between display ProG and SEt
  • by pressing and holding the button ^ you select entry into the setting of time programs (ProG) or into the menu (SEt)

The programming step number is indicated on the lower bar graph by the number of displayed lines (1-6). The day of the week for which the given program step is set is displayed in the upper corner of the display.

If the program type „working day / weekend“ is selected, then for working days the symbols „1“, „2“, „3“, „4“, „5“ are displayed, and for the weekend „6“, „7“.
If the program type „every day the same“ is displayed, then for working days the symbols „1“, „2“, „3“, „4“, „5“, „6“ and „7“ are displayed.
If a programming step is to remain unused, dashes are set in the item StA.

Entering the settings menu

ELKO RFTC-50 G Autonomous Temperature Controller
11

ELKO RFTC-50 G Autonomous Temperature Controller 12

ELKO RFTC-50 G Autonomous Temperature Controller 13

OFF – switched off

The set value means a shift in local time (time zone) against UTC, range -1 to +2 (covers the countries in the EU). For EU countries it is valid that the time shift always occurs at 1:00 UTC, it is thus necessary to know the time zone to fi nd out at what time in local time the winter and summer daylight savings time shifts are to occur.

In the upper row, the period of vacation timer is shown in hours or days, and the lower row indicates the required temperature.

By pressing and holding ^ you unlock the temperature to settings and by short presses of the buttons ^ ^ you set the required temperature. By pressing and holding the button ^ you confi rm the set temperature while switching into the setting of the time range of the vacation timer – days or hours – and further units and tens of days or hours.

ELKO RFTC-50 G Autonomous Temperature Controller 14

  • OFF – floor temperature function is switched off , the actuator(s) of the type RFSA-6x is(are) controlled.
    Range 20 – 35 °C, floor temperature function is switched on, the actuator(s) of the type RFSTI-11B is(are) controlled (with date of manufacture from 03/2013).

  • Used for tempering the floor when using a different heating source.
    OFF – the function for maintaining the minimum floor temperature is switched off . Range 20 °C up to the max. set floor temperature (FL-H).

Example of programming the RFTC-50/G
Example of settings for actuator RFSA-6x, RFSC-61, RFUS-61 and RFSTI-11B

ELKO RFTC-50 G Autonomous Temperature Controller 15

Example for 1 actuator type RFSTI-11B with RF address 001234 with hysteresis N of 0.6 °C, heating function, time format 24 hr., daylight savings time switched off , non-freezing temperature set to 7 °C, maximum floor temperature 28 °C, minimum floor temperature 21°C, time correction 0.

ELKO RFTC-50 G Autonomous Temperature Controller 16

Example of settings for 1 actuator type RFSA-6x with RF address 001234 with hysteresis of 0.6 °C, heating function, time format 24 hr., daylight savings time shit switched off , non-freezing temperature set to 7 °C, time correction 0.

ELKO EP, s.r.o.
Palackého 493 | 769 01 Holešov, Všetuly Czech Republic
tel.: +420 573 514 211 | fax: +420 573 514 227 [email protected] | www.elkoep.com
Made in Czech Republic
4863 02-98/2016 Rev.: 4