ELKO Luxury Version Wireless Shutter Control User Manual
- June 4, 2024
- ELKO
Table of Contents
WIRELESS
SHUTTER CONTROL
(LUXURY VERSION)
Luxury Version Wireless Shutter Control
Combination of iNELS wall-mounted wireless controller and shutter switching device.
Package
Glass touch controller – 4 buttons, SHARP RFGB-40/W, RFGB-40/B
Glass touch controller – 4 buttons, ROUND RFGB-240/W, RFGB-240/B
Switch unit for shutters RFJA-32B-SL
EAN 8595188183154 (Glass touch controller – 4 buttons, BLACK SHARP + Switch
unit for shutters)
EAN 8595188183161 (Glass touch controller – 4 buttons, WHITE SHARP + Switch
unit for shutters)
EAN 8595188183178 (Glass touch controller – 4 buttons, BLACK ROUND + Switch
unit for shutters)
EAN 8595188183185 (Glass touch controller – 4 buttons, WHITE ROUND + Switch
unit for shutters)
The individual elements in the iNELS set are paired and their functions are
preset.
iNELS kit for shutters enables its remote control.
The settings of the wall controllers can be changed – see detailed manuals of iNELS elements.
Glass touch controller – 4 buttons,
SHARP/ROUND, RFGB-40/RFGB-240
RFGB-40/B – glass touch controller, SHARP – black, 4-buttons
RFGB-40/W – glass touch controller, SHARP – white, 4-buttons
RFGB-240/B – glass touch controller, ROUND – black, 4-buttons
RFGB-240/W – glass touch controller, ROUND – white, 4-buttons
Characteristics
RFGB-240
- The wireless control – is used to control, lights, gates, garage doors, shutters, etc.
- Thickness is only 8 mm.
- 4 capacitive buttons allow you to control 2/4 of the components.
- Fast installation on any surface – the rear base allows screwing to the walls, gluing with double-sided tape, or just laying on the table
Replacement of a battery in 3 steps
Assembly
Adhesive
| |
---|---|---
Peel off one protective layer on the double-sided adhesive sheets and stick
them to the marked places on the controller.| Peel off the second protective
layer on the double-sided adhesive sheets and place the control in the
prepared place.| If the device is installed on glass, cover it with a cover
foil
In the installation box or on the wall
| |
---|---|---
Mount the snap bar on the controller into the installation box or on the wall|
Place the mounting jig on the KU box and screw it on| Snap-on the controller.
Technical parameters
RFGB-40/RFGB-240
Power voltage: | about 2 years depending on the frequency of use |
---|---|
Battery life: | Red LED |
Transmission indication | 4 |
A number of capacitive buttons: | RFIO |
Communication Protocol: | 2 |
Frequency: | 868.5 MHz |
Signal transmission method: | one-way addressed message |
Range: | in the open up to 200 m |
Material: | Glass |
Other data
Operating Temperature:| -10 … +50 °C (14 … 122 °F)
Working Position| any
Mounting:| adhesive, screw
Protection| IP20
Pollution degree:| 2
Dimension:| SHARP 94 x 94 x 8 mm (3.7“ x 3.7“x 0.3“) ROUND 100 x 100 x 8 mm
(3.9“ x 3.9“ x 0.3“)
Weight:| SHARP 107 g/ ROUND 108 g
Related standards:| EN 60669, EN 300 220, EN 301 489
Notes
Switch unit for shutters
RFJA-32B-SL
Characteristics RFJA-32B-SL
- The switching unit for blinds has 2 output channels used to control garage doors, gates, blinds, awnings, etc…
- It can be combined with system components iNELS RF Control 2 with RFIO 2 protocol.
- The BOX design lets you mount it right in an installation box, a ceiling or a motor drive cover.
- Short presses of the controller enable tilting of lamellas, and a long press enables you to draw the blinds up or down to the end position.
- Each of the units may be controlled by up to 25 channels (1 channel represents one assigned controller).
- The programming button on the unit is also used for manual control of the output.
- For components, it is possible to set the repeater function via the RFAF / USB service device.
- Range up to 200 m (in open space), if the signal is insufficient between the controller and unit, use the signal repeater RFRP-20 or protocol component RFIO 2 that supports this feature.
- Communication frequency with bidirectional protocol iNELS RF Control 2 (RFIO 2 ).
Installation options
Technical parameters
RFJA-32B-SL
Supply voltage: | 230 V AC / 50 – 60 Hz |
---|---|
Apparent input: | 7 VA / cos 9 |
Dissipated power: | 0.7 W |
Supply voltage tolerance: | +10 -15 % |
Output:
Number of contacts:| 2x switching (AgSnO2)
Rated current:| 8 A / AC1
Switching power:| 2000 VA / AC1
Peak current:| 10 A / <3 s
Switching voltage:| 250 V AC1
Control:
RF, by command from transmitter:| 868.5 MHz
Manual control:| PROG (STOP, A, STOP, )
Other data:
Operating temperature:| -15 … + 50 °C (5 … 122 °F)
Operating position:| any
Mounting:| free at lead-in wires
Protection:| IP30
Overvoltage category:| III.
Dimensions:| 43 x 44 x 22 mm
Weight:| 45 g
Related standards:| EN 60730, EN 63044, EN 300 220, EN 301 489
Connection
Indication, manual control
- LED STATUS – an indication of the device status.
- Manual control is performed by pressing the PROG button.
- Programming is performed by pressing the PROG button for more than 1s.
- Terminal block for connection of buttons. IN1 – direction button up IN2- button down.
In the programming and operating mode, the LED on the component lights up at the same time each time the button is pressed – this indicates the incoming command
- LED/button PROG
- Addresses for individual relays (channels)
- Terminal block – connection for external button
- Terminal block – connecting the neutral conductor
- Terminal block – load connection
- Terminal block for connecting the phase conductor
Radiofrequency signal penetration through various construction materials
Range up to 200 m in open space, if the signal is insufficient between the
controller and unit, use the signal
repeater RFRP-20 or protocol component RFIO2 that supports this feature.
Warning
The instruction manual is designated for mounting and also for the usage of
the device. It is always a part of its packing. Installation and connection
can be carried out only by a person with adequate professional qualifi cation
with understanding this instruction manual and functions of the device, and
while observing all valid regulations. The trouble-free function of the device
also depends on transportation, storing, and handling. In case you notice any
sign of damage, deformation, malfunction or missing part, do not install this
device and return it to its seller. It is necessary to treat this product and
its parts as electronic waste after its lifetime is terminated. Before
starting the installation, make sure that all wires, connected parts or
terminals are de-energized. While mounting and servicing observe safety
regulations, norms, directives, and professional, and export regulations for
working with electrical devices. Do not touch parts of the device that are
energized – life threat. Due to the transmissivity of RF signals, observe the
correct location of RF components in a building where the installation is
taking place. RF Control is designated only for mounting in interiors. Devices
are not designated for installation in exteriors and humid spaces. They must
not be installed into metal switchboards and into plastic switchboards with
metal doors – transmissivity of RF signal is then impossible. RF Control is
not recommended for pulleys etc. – the radiofrequency signal can be shielded
by an obstruction, interfered, a battery of the transceiver can get fl at, etc.
and thus disable the remote control.
Designed & Manufactured by:
ELKO EP, s.r.o. Palackého 493, 769 01 Holešov, Všetuly,
Czech republic, www.elkoep.com, Hotline: +420 800 100