LUMASCAPE PowerSync PS4 Data Injector LS6550 Instruction Manual

June 3, 2024
LUMASCAPE

PowerSync® PS4 Data Injector LS6550         Installation

Instructions


GENERATION 2

LUMASCAPE PowerSync PS4 Data Injector LS6550

LS6550 - Danger 1

ISOLATE DEVICE FROM POWER

LS6550 - Danger 2

Failure to isolate power supply before installation or maintenance may result in fire, serious injury, electric shock, death and may damage the device.


Product Warranty is void if product is not installed as per installation instructions and in compliance with the local electrical code.


LS6550 - Prohibited 1 LS6550 - Prohibited 2

NO POWER TOOLS            DO NOT USE SILICONE ON OUTSIDE SURFACE

LS6550 - Prohibited 3

KEEP ELECTRONICS FREE FROM DIRECT AND MOISTURE

LS6550 - Prohibited 4

DO NOT HOSE OR PRESSURE CLEAN


READ ALL SAFETY INSTRUCTIONS FIRST

› Follow instructions carefully; failure to do so will void warranty.
› Ensure installation complies with local laws and applicable standards.
› Keep PowerSync free from debris and in an easily accessible location.
› Only use Lumascape power supplies, and leader cables.
› Ensure mains input power is surge protected.
Never make connections whilst power is connected.
› Do not make modifications or alter product.
› Connections and LS6550 Data Injector is to be kept clean and dry at all times.
› A PowerSync terminator is required on the last fitting of run.

Products and specifications are subject to change without notice.
IN0194-220729


LUMASCAPE logo b1

ARCHITECTURAL & FACADE LIGHTING | lumascape.com

LS6550 - Features

  1. DMX In

  2. CONTROL SIGNAL
    Either 0-10 V or PWM control signal

  3. DIN RAIL MOUNTING
    Two (2) mounting options, side or back installation

  4. DMX TERMINATOR
    LS6407-R

  5. 30-48 Vdc Power In
    30-48 Vdc maximum in from PSU

  6. POWERSYNC OUT
    Connect PowerSync leader cable to first luminaire in chain

Control via 0-10 V or PWM Input

STEP 1
Strip the individual wire strands of the data cable as per the specification below.

LS6550 - Connecting Luminaires Step 1

  1. Signal
  2. STRANDED OR SOLID
    0.2-1.5 mm²
    24-16 AWG

STEP 2
Pull up to remove terminal block.

LS6550 - PWM Input Step 2

STEP 3
Using a screwdriver, loosen the screw to open the terminal and insert stranded wire, then screw back up.

LS6550 - PWM Input Step 3

STEP 4
Reconnect terminal block.

LS6550 - PWM Input Step 4

Label|

Designation

---|---
Use with 0-10 V
Sinking Dimmers¹
| Use with 0-10 V
Sourcing Dimmers²
| PWM³
10 V Out| 10 V source| Not connected| Not connected
Ch 1 In| Channel 1 return| Channel 1 +| Channel 1 +
Ch 2 In| Channel 2 return| Channel 2 +| Channel 2 +
Com –| Not connected| Common –| Common –

¹ Mode 5, ² Mode 3, ³ Mode 4
Refer to Mode Switch table


PSU Connections

STEP 1
Strip the individual wire strands of the data cable as per the specification below.

LS6550 - PSU Connections Step 1

  1. Power
  2. 1.3-6 mm²/16-8 AWG

STEP 2
Push Orange sliders in then pull down to remove terminal block.

LS6550 - PSU Connections Step 2

STEP 3
Using a screwdriver, insert into hole, push to hold open terminal while inserting stranded wire.

LS6550 - PSU Connections Step 3

STEP 4
Reconnect terminal block.

LS6550 - PSU Connections Step 4

Color|

PowerSync Out Cable

---|---

2-Core

Red|

Power +

Black|

Power –

Connecting Luminaires via PowerSync Leader Cable

STEP 1
Strip the individual wire strands of the data cable as per the specification below.

LS6550 - Connecting Luminaires Step 1

  1. Signal
  2. STRANDED OR SOLID
    0.2-1.5 mm²
    24-16 AWG

STEP 2
Push Orange sliders in then pull down to remove terminal block.

LS6550 - Connecting Luminaires Step 2

STEP 3
Using a screwdriver, insert into hole, push to hold open terminal while inserting stranded wire.

LS6550 - Connecting Luminaires Step 3

STEP 4
Reconnect terminal block.

LS6550 - Connecting Luminaires Step 4

Color|

PowerSync In Cable

---|---

3-Core

Red|

Power +

Black|

Power –

Orange|

Data +


lumascape.com

10 Position Mode Switch

| Label| Designations
---|---|---
TYPICAL OPERATION MODE | 0| DMX/RDM Only
| 1| DMX/RDM + Relay
TEST MODES | 2| Test All Channels Off
3| Test All Channels On
4| Test 4 Color Cycle
| 5| 0-10 V Sourcing
| 6| 0-10 V Sinking
| 7| CRMX (Optional)
| 8| USB
| 9| Firmware Update

NOTE:

  • This function list is ONLY for Generation 2 PowerSync Injectors.
  • Generation 2 is marked on the faceplate of the label on the PowerSync Injector.

The LS6550 provides three (3) test modes for PowerSync luminaires. These require only connected luminaires and power, and no connected input signal. If an input signal is connected, the LS6550 will not respond to this signal in any of the modes below.

NOTE: These test signals apply to the relevant unit’s PowerSync output only ­­ it will not be passed through on the DMX/RDM connectors if multiple LS6550 units are connected.


Indicator Lights
INDICATOR LIGHTS
LED Indicator Event Appearance
Power In Main input power Illuminates
Power Out Output power relay closed Illuminates
DMX Traffic DMX Traffic detected
Dimming signal detected Flashing with signal

1.2 Hz blinking, proportional to input level
PS4 Traffic| PowerSync output enabled| Illuminates
Status| Startup
Normal operation| 3 flashes
1 flash, every 5 seconds
| Circuit fault detected
Over voltage
Short circuit| 2 flashes, every 5 seconds
3 flashes, every 5 seconds
| PowerSync fault detected
Power fault/over temperature| 4 flashes, every 5 seconds
Check| Relay open
Manual override
Startup/Fault detected| Power out, light off
Flashing
Illuminates
USB| USB connected| Illuminates/flashes with data


RJ45

Plug                     Socket                  Pin 1

DMX PIN DESIGNATIONS

Signal|

Connector Type RJ45 Std

---|---
Data +|

1

Data ­-|

2

Ground|

7


ARCHITECTURAL & FACADE LIGHTING

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>