LUMASCAPE PowerSync PS4 Data Injector LS6550 Instruction Manual
- June 3, 2024
- LUMASCAPE
Table of Contents
PowerSync® PS4 Data Injector LS6550 Installation
Instructions
GENERATION 2
ISOLATE DEVICE FROM POWER
Failure to isolate power supply before installation or maintenance may result in fire, serious injury, electric shock, death and may damage the device.
Product Warranty is void if product is not installed as per installation instructions and in compliance with the local electrical code.
NO POWER TOOLS DO NOT USE SILICONE ON OUTSIDE SURFACE
KEEP ELECTRONICS FREE FROM DIRECT AND MOISTURE
DO NOT HOSE OR PRESSURE CLEAN
READ ALL SAFETY INSTRUCTIONS FIRST
› Follow instructions carefully; failure to do so will void warranty.
› Ensure installation complies with local laws and applicable standards.
› Keep PowerSync free from debris and in an easily accessible location.
› Only use Lumascape power supplies, and leader cables.
› Ensure mains input power is surge protected.
› Never make connections whilst power is connected.
› Do not make modifications or alter product.
› Connections and LS6550 Data Injector is to be kept clean and dry at all
times.
› A PowerSync terminator is required on the last fitting of run.
Products and specifications are subject to change without notice.
IN0194-220729
ARCHITECTURAL & FACADE LIGHTING | lumascape.com
-
DMX In
-
CONTROL SIGNAL
Either 0-10 V or PWM control signal -
DIN RAIL MOUNTING
Two (2) mounting options, side or back installation -
DMX TERMINATOR
LS6407-R -
30-48 Vdc Power In
30-48 Vdc maximum in from PSU -
POWERSYNC OUT
Connect PowerSync leader cable to first luminaire in chain
Control via 0-10 V or PWM Input
STEP 1
Strip the individual wire strands of the data cable as per the specification
below.
- Signal
- STRANDED OR SOLID
0.2-1.5 mm²
24-16 AWG
STEP 2
Pull up to remove terminal block.
STEP 3
Using a screwdriver, loosen the screw to open the terminal and insert stranded
wire, then screw back up.
STEP 4
Reconnect terminal block.
Label|
Designation
---|---
Use with 0-10 V
Sinking Dimmers¹| Use with 0-10 V
Sourcing Dimmers²| PWM³
10 V Out| 10 V source| Not connected| Not connected
Ch 1 In| Channel 1 return| Channel 1 +| Channel 1 +
Ch 2 In| Channel 2 return| Channel 2 +| Channel 2 +
Com –| Not connected| Common –| Common –
¹ Mode 5, ² Mode 3, ³ Mode 4
Refer to Mode Switch table
PSU Connections
STEP 1
Strip the individual wire strands of the data cable as per the specification
below.
- Power
- 1.3-6 mm²/16-8 AWG
STEP 2
Push Orange sliders in then pull down to remove terminal block.
STEP 3
Using a screwdriver, insert into hole, push to hold open terminal while
inserting stranded wire.
STEP 4
Reconnect terminal block.
Color|
PowerSync Out Cable
---|---
2-Core
Red|
Power +
Black|
Power –
Connecting Luminaires via PowerSync Leader Cable
STEP 1
Strip the individual wire strands of the data cable as per the specification
below.
- Signal
- STRANDED OR SOLID
0.2-1.5 mm²
24-16 AWG
STEP 2
Push Orange sliders in then pull down to remove terminal block.
STEP 3
Using a screwdriver, insert into hole, push to hold open terminal while
inserting stranded wire.
STEP 4
Reconnect terminal block.
Color|
PowerSync In Cable
---|---
3-Core
Red|
Power +
Black|
Power –
Orange|
Data +
10 Position Mode Switch
| Label| Designations
---|---|---
TYPICAL OPERATION MODE | 0| DMX/RDM Only
| 1| DMX/RDM + Relay
TEST MODES | 2| Test All Channels Off
3| Test All Channels On
4| Test 4 Color Cycle
| 5| 0-10 V Sourcing
| 6| 0-10 V Sinking
| 7| CRMX (Optional)
| 8| USB
| 9| Firmware Update
NOTE:
- This function list is ONLY for Generation 2 PowerSync Injectors.
- Generation 2 is marked on the faceplate of the label on the PowerSync Injector.
The LS6550 provides three (3) test modes for PowerSync luminaires. These require only connected luminaires and power, and no connected input signal. If an input signal is connected, the LS6550 will not respond to this signal in any of the modes below.
NOTE: These test signals apply to the relevant unit’s PowerSync output only it will not be passed through on the DMX/RDM connectors if multiple LS6550 units are connected.
Indicator Lights
INDICATOR LIGHTS
LED Indicator | Event | Appearance |
---|---|---|
Power In | Main input power | Illuminates |
Power Out | Output power relay closed | Illuminates |
DMX Traffic | DMX Traffic detected | |
Dimming signal detected | Flashing with signal |
1.2 Hz blinking, proportional to input level
PS4 Traffic| PowerSync output enabled| Illuminates
Status| Startup
Normal operation| 3 flashes
1 flash, every 5 seconds
| Circuit fault detected
Over voltage
Short circuit| 2 flashes, every 5 seconds
3 flashes, every 5 seconds
| PowerSync fault detected
Power fault/over temperature| 4 flashes, every 5 seconds
Check| Relay open
Manual override
Startup/Fault detected| Power out, light off
Flashing
Illuminates
USB| USB connected| Illuminates/flashes with data
RJ45
Plug Socket Pin 1
DMX PIN DESIGNATIONS
Signal|
Connector Type RJ45 Std
---|---
Data +|
1
Data -|
2
Ground|
7
ARCHITECTURAL & FACADE LIGHTING