LUMASCAPE LS5030 Woda W3 Generation 2 Projector Instruction Manual
- May 15, 2024
- LUMASCAPE
Table of Contents
WODA W3 LS5030 Generation 2
LS5030 Woda W3 Generation 2 Projector
MODEL | LSS030 |
---|---|
PART NUMBER | LSSO30 — xxx XxX X X XX XX XK XXX XK |
INSTALLATION TYPE | UNDERWATER, WET/DRY, DRY |
IP RATING | IP68 to 33’ (10 m) |
SUPPLY VOLTAGE | 30 Vdc |
INSTRUCTIONS COVER | PowerSync? |
DIMENSIONS (LxWxH) | Refer to included drawings |
WEIGHT | 77 Ib (3.5 kg) |
WATER TEMPERATURE | -4°F to 95°F (-20°C to 35°C) |
Tools Required
Included Components
| Keep Electronics Free From Dirt and Moisture
---|---
| Do Not Use Power Tools
on Screws
| No use herramientas eléctricas en los tornillos
| Keep Away from Flammable Materials
| Do Not Hose or Pressure
Clean
| Do Not Use Silicone On
Outside Surface
| Do Not Cut Cable to the
Luminaire
Submersible (Fountain/Water Feature/Marine Applications Only): 24 W & 48 W
Wiring Designations
PowerSync (3-Core)
Designation | Colo r |
---|---|
+ DC | Red |
– DC | Black |
Data | Orange |
Do not Hi-Pot test
WARNING – Product Warranty is void if product is not installed as per
installation instructions and in compliance with all local and provincial
codes.
Please read and follow all safety instructions carefully. Failure to do so
will void warranty.
- Ensure installation complies with local electrical rules and regulations.
- All electrical work must be performed by a licensed electrician.
- Class III product SELV (symbol 3).
- For LED Options 2,700K, 3,000K, Red, Green, Blue, RGBA, RGBW, Tunable White: This product contains a light source of energy efficiency class G. › For LED Options 3,500K, 4,000K, 5,000K: This product contains a light source of energy efficiency class F.
- All luminaires may become hot. Use discretion on where the luminaire is mounted. Take care when setting luminaire as it may become hot.
- Luminaire should only be used complete with protective shield. If protective shield is cracked, immediately stop using luminaire. Isolate light source, keep it dry and immediately contact Lumascape for replacement of protective shield (symbol 10).
- If the external flexible cable or cord of this luminaire is damaged, it shall be exclusively replaced by Lumascape or their service agent in order to avoid a hazard.
- The light source contained in this luminaire shall only be replaced by Lumascape or their service agent.
- Do not stare at the operating light source. The luminaire should be positioned so that prolonged staring into the luminaire at a distance closer than 26’ (8 m) is not expected (symbol 13)
- Ensure mains input power to power supply is surge protected.
- Never make or break connections while the circuit is energized.
- Do not make modifications or alter the product.
- Keep luminaire clean and free of debris.
- Only clean with warm water.
- Do not use chemicals or abrasives to clean luminaire as this may void the product warranty.
- Connections are to be kept clean and dry at all times.
- 48 W option only suitable for use in underwater applications.
- 24 W option suitable for use in both underwater and wet/dry applications.
CAUTION Risk of Electric Shock