LUMASCAPE LS3332 Erden Brass EB3 Foundation User Guide

June 2, 2024
LUMASCAPE

LUMASCAPE LS3332 Erden Brass EB3 Foundation

LUMASCAPE-LS3332-Erden-Brass-EB3-Foundation-product

Product Information

Specifications

  • Model: ERDEN BRASS EB3 FOUNDATION
  • Installation Type: Direct Burial
  • IP Rating: IP67
  • Supply Voltage: 240V

FAQ

  • Q: What should I do if the product gets hot during operation?
    • A: Use caution and avoid direct contact with the hot surfaces. Allow the product to cool down before handling.
  • Q: Can I install the product indoors?
    • A: The product is suitable for direct burial and outdoor use. Indoor installation may require additional considerations.

Included Components

  • Instructions
  • Luminaire

Specifications

  • MODEL: LS3332
  • PART NUMBER: LS3332 – 14D xxx x x xx xx x 21 Q xx xx x
  • INSTALLATION TYPE: IN-GROUND/IN-GRADE: DIRECT BURIAL
  • IP RATING: IP68
  • SUPPLY VOLTAGE: 220 to 240 Vac, 50 Hz (International)
    • 120/277 Vac, 60 Hz (North America)
  • INSTRUCTIONS COVER: DALI®, 0 to 10 V, Non-Dimmable
  • DIMENSIONS (LxWxH): Refer to included drawings
  • WEIGHT: 6.2 lb (2.8 kg)
  • AMBIENT TEMPERATURE: -4ºF to 122ºF (-20ºC to 50ºC)
  • STATIC LOAD RATING: 2,866 lb (1,300 kg)

Precautions

  • No Downward Force
  • Do Not Overtighten
  • Do Not Use Power Tools on Screws
  • Keep Electronics Free From Dirt and Moisture
  • Keep Away from Flammable Materials
  • Do Not Hose or Pressure Clean
  • Do Not Use Silicone On Outside Surface
  • Do Not Cut Cable to the Luminaire

Warning

  • Do not allow soil, fill or any material to build up around the luminaire. Warranty will be void.

Installation

LUMASCAPE-LS3332-Erden-Brass-EB3-Foundation-fig-15

Correct Installation

LUMASCAPE-LS3332-Erden-Brass-EB3-Foundation-fig-11

Incorrect Installation. Warranty Void.

LUMASCAPE-LS3332-Erden-Brass-EB3-Foundation-fig-12

Legend Key:

CAUTION: Risk of Electric Shock.

Wiring Designations

Non-Dimmable 3-Core (International)

Designation Color
Active Brown
Neutral Blue
Earth Green/Yellow

Do not Hi-Pot test

Non-Dimmable 3-Core (North America)

Designation Color
Active Black
Neutral White
Earth Green/Yellow

Do not Hi-Pot test

DALI 5-Core (International)

Designation Color
Active Brown
Neutral Blue
Earth Green / Yellow
DALI + Grey
DALI – Black

Do not Hi-Pot test

0 to 10 V 5-Core (North America)

Designation Color
Active Black
Neutral White
Earth Green / Yellow
0-10 V + Purple
0-10 V – Grey

Do not Hi-Pot test

Dimensions

LUMASCAPE-LS3332-Erden-Brass-EB3-Foundation-fig-17

Introduction

Please read and follow all safety instructions carefully. Failure to do so will void warranty.

WARNING:  Product Warranty is void if product is not installed as per installation instructions and in compliance with all local and provincial codes.

  • Ensure installation complies with local electrical rules and regulations.
  • All electrical work must be performed by a licensed electrician.
  • Protective earth; protective group (symbol 7).
  • For LED Options 2,700K, 3,000K, Red, Green, Blue, RGBA, RGBW, Tunable White: This product contains a light source of energy efficiency class G.
  • For LED Options 3,500K, 4,000K, 5,000K: This product contains a light source of energy efficiency class F.
  • All luminaires may become hot. Use discretion on where the luminaire is mounted. Take care when setting luminaire as it may become hot.
  • Luminaire should only be used complete with protective shield. If protective shield is cracked, immediately stop using luminaire. Isolate light source, keep it dry and immediately contact Lumascape for replacement of protective shield (symbol 11).
  • If the external flexible cable or cord of this luminaire is damaged, it shall be exclusively replaced by Lumascape or their service agent in order to avoid a hazard.
  • The light source contained in this luminaire shall only be replaced by Lumascape or their service agent in order to avoid a hazard.
  • Do not stare at the operating light source. The luminaire should be positioned so that prolonged staring into the luminaire at a distance closer than 23′ (7 m) is not expected (symbol 13).
  • Basic insulation has been maintained between line voltage and the control conductors.
  • Ensure mains input power to power supply is surge protected.
  • Never make or break connections while the circuit is energized.
  • Do not make modifications or alter the product.
  • Keep luminaire clean and free of debris.
  • Only clean with warm water.
  • Do not use chemicals or abrasives to clean luminaire as this may void the product warranty.
  • Connections are to be kept clean and dry at all times.
  • Suitable for use indoors or outdoors.
  • The luminaire’s cable must be connected to an IP66/68 rated external junction box.

ARCHITECTURAL & FACADE LIGHTING 

Scan

Documents / Resources

| LUMASCAPE LS3332 Erden Brass EB3 Foundation [pdf] User Guide
LS3332 Erden Brass EB3 Foundation, LS3332, Erden Brass EB3 Foundation, Brass EB3 Foundation, EB3 Foundation, Foundation
---|---
| LUMASCAPE LS3332 Erden Brass EB3 Foundation [pdf] User Guide
LS3332 IN0239-240307, LS3332, Erden Brass EB3 Foundation, Brass EB3 Foundation, EB3 Foundation, Foundation

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals