LUMASCAPE LS9407LED Vedita Downlight Luminaire Instruction Manual

June 3, 2024
LUMASCAPE

LUMASCAPE LS9407LED Vedita Downlight Luminaire Instruction

Vedita Ceiling/Cavity Mount

Warranty void if not installed per instructions and local electrical code

Note: Fixture uses intelligent driver. Always leave on for 20 seconds unless programing

WARNING

  • It is strongly recommended to a use Lumascape transformer
  • Opening luminaire will void warranty

INSTALLATION

  1. Install in accordance with National Electric Code, ANSI/NFPA 70 or the Canadian Electrical Code, Part I (CEC), CSA C22.1
  2. This luminaire is approved for installation as a Class 2 rated luminaire in general purpose locations. Make all connections according to the Class 2 rules of the local jurisdiction. This luminaire is not approved for use in plenums.LUMASCAPE-LS9407LED-Vedita-Downlight-Luminaire-Instruction-FIG-1
  3. Mark locations of luminaires and using holesaw supplied, cut hole in installation surface. Please note, the installation surface thickness must be within the range of 0.35” to 0.80”
  4. Collapse the legs of the mounting clip and push the clip up into the hole. The clip should be a tight fit.LUMASCAPE-LS9407LED-Vedita-Downlight-Luminaire-Instruction-FIG-3
  5. Ensure placement of junction box is close enough to luminaire for the factory-fitted cord length to reach to the junction box. Secure cord and terminate in accordance with local wiring rules. Please note: These luminaires are generally not ‘Hot Swappable”. Do not disconnect or reconnect luminiares to energized Class 2 circuit
  6. Connect luminaire to the load side of the Class 2 power supply. Any joint must be dry and water tight or warranty will be void.
  7. Once the circuit and all luminiares are confirmed as working, push luminaire into mounting clip.

NOTE: The orange and grey wires are for optional pwm digital dimming using 0-10 V.

If dimming is not required, do not connect the orange and grey wires. In all cases they are to be sealed and kept dry. Failure to do so may result in the intelligent driver dimming the luminaire due to a voltage differential between the two conductors.

Wiring for Non-Dimming Diagram

LUMASCAPE-LS9407LED-Vedita-Downlight-Luminaire-Instruction-
FIG-5

NOTE: The above diagram is intended to show electrical pathways between luminaires and ancillary devices. This diagram is not intended to show type or color of cord/wire, wire gauge or approved use of the cord/wire supplied with luminaires. Consult the luminaire-specific cutsheet or the factory for detailed specifications.

IMPORTANT: For instructions on how to fine tune the brightness of the luminaire, refer to instruction sheet IN0059US “How to adjust the brightness for your d5 equipped luminaire”. Please note, this capability only applies for luminaires not connected to any other control signal.

Wiring for Dimming Configurations

Please refer to the appropriate wiring diagram for information on required system components and connections.

Dimmable Wiring Diagram Reference

Input Voltage| LED Color| Control Type| Wiring Diagram
---|---|---|---
13-DIM| Single Color| PwM| 2,4

Wiring Polarity

red V+
black V –
orange DIM+ (connection optional)
grey DIM – (connection optional)

NOTE: Connect dimming wires only  if needed. Otherwise isolate.

lumascape.com 1940 Diamond Street, San Marcos, California 92078, United States of America

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

LUMASCAPE User Manuals

Related Manuals