PRODUCT

SPECIFICATIONS

  • Cover Material ……………………………………..Brass(C), Nickel-Plated Brass(S), Stainless Steel (SS)
  • Receptacle Rating …………………………………………………………………………………………..20A 125VAC
  • Box Material ……………………………………………………………………………………………..Galvanized Steel
  • Knockout size …………………………………………………………………………………………………1/2″ and 3/4″
  • Adjustable Height ………………………………………………………………………………………….up to 1″ depth

DESCRIPTION/ FEATURES

Included is a Two-gang floor box assembly with a tamper & weather resistant 20 amp duplex receptacle and datacom, FB-06 box, gasket, and cover.

  • Compact and stylish design with adjustable height function metal box with the choice of Brass(C), Nickel-Plated Brass(S), or Stainless steel (SS).
  • Corrosion-resistant hardware ensures long life span and reliable performance. Easy access to power when you need it.
  • Used for carpet and wood floors

WARNING

Turn the POWER OFF at the circuit breaker before installing the Floor Box
Read and understand these instructions before installing. This device is intended for installation by the National Electric Code and local regulations. It is recommended that a qualified electrician perform this installation. Make sure to turn off the circuit breaker or fuse(s) and make sure the power is off before wiring the device. Use copper wire only, or equivalent.

NOTES: 10-12 AWG Stranded or Solid Copper wire is recommended.

DIMENSIONS

FLOOR BOX INSTALLATION

Before Installation:
Ensure there is sufficient depth & space below the subfloor.

Step 1: For carpeted floors:
Cut out a section of carpet smaller than the size of the cover.

For wood sub-floors and finished hardwood floors:

  • Tape the template on the area you want to place the floor box.
  • Use a knife to cut the outline of the box. Start with the ears and move inwards.
  • Following the outline, cut the box shape without the ears completely through thesub-floor or hardwood floor.
  • Following the outline, cut 3/8″ deep into the sub-floor or hardwood for the mounting ears.
    • Using a router is recommended

Step 2

  • Remove knockouts and secure the box onto the floor. Pull the wires through the opening of the floor and the knockout and connect the wires based on the wiring diagram.
  • Use the proper connector/ clamp at the knockouts to secure the wires and to avoid accidental wire stripping.
  • Secure the box to the opening using wood screws.

WIRING DIRECTIONS

ENERLITES-975510-C-D-2-Gang-Brass-Floor-Box-w
-TRWROutlet-and-Datacom-FIG-3

WARRANTY INFORMATION

This device is warranted to be free of material and workmanship defects for 2 years from the date of purchase. An original receipt or proof of purchase from an authorized retailer must be presented upon warranty claim. Claims must be verified and approved by Enerlites, Inc. Warranties from other Enerlites products may vary. This warranty is non-transferable and does not cover normal wear and tear or any malfunction, failure, or defect resulting from misuse, abuse, neglect, alteration, modification, or improper installation. To the fullest extent permitted by the applicable state law, Enerlites shall not be liable to the purchaser or end-user customer of Enerlites products for direct, indirect, incidental, or consequential damages even if Enerlites has been advised of the possibility of such damages. Enerlites’ total liability under this or any other warranty, express or implied, is limited to repair, replacement or refund. Repair, replacement or refund are the sole and exclusive remedies for breach of warranty or any other legal theory.

REV 20230802

FAQ

  • Q: Is this product suitable for outdoor use?
    • A: Yes, this product is tamper and weather-resistant, making it suitable for outdoor installations.
  • Q: What is the recommended wire gauge for installation?
    • A: It is recommended to use 10-12 AWG Stranded or Solid Copper wire for installation.