SmartGen BAC2405CF Battery Charger User Manual
- June 3, 2024
- SmartGen
Table of Contents
SmartGen BAC2405CF Battery Charger
SmartGen — make your generator smart
SmartGen Technology Co., Ltd.
No.28 Jinsuo Road
Zhengzhou
Henan Province
P. R. China
Tel: 0086-371-67988888/67981888
0086-371-67991553/67992951
0086-371-67981000(overseas)
Fax: 0086-371-67992952
Web: www.smartgen.com.cn
www.smartgen.cn
Email: sales@smartgen.cn
All rights reserved. No part of this publication may be reproduced in any
material form (including photocopying or storing in any medium by electronic
means or other) without the written permission of the copyright holder.
Applications for the copyright holder’s written permission to reproduce any
part of this publication should be addressed to Smartgen Technology at the
address above.
Any reference to trademarked product names used within this publication is
owned by their respective companies.
Smart
G en Technology reserves the right to change the contents of this document
without prior notice.
Software Version
Date | Version | Note |
---|---|---|
2016-03-05 | 1.0 | Original Release |
2017-11-09 | 1.1 | Update “CASE DIMENSIONS” |
OVERVIEW
Fit with up-to-date power supply device, float charger BAC2405CF is specially designed for meet the charging characteristics of the lead-acid engine starter batteries and can be used for long-term float charging of 24V lead-acid batteries. The maximum output current is 5A.
PERFORMANCE AND CHARACTERISTICS
- Switch power supply structure, wide input alternating voltage range, small size, light weight, high efficiency rate;
- Automatic two-stage charging process carried out according to storage battery charging characteristics to prevent overcharging and significantly prolong battery lifetime;
- Built-in output current protective circuit, which can give effective protection when output over current, short-circuit or reverse connection occurs. After troubleshooting over current, short-circuit or reverse connection, the output will be recovered automatically.
- With port of mains failure alarm, the port will close immediately while occurring AC input outage.
- Suitable for 24V storage battery. The maximum output current of is 5A.
- LED display: float charging indicator and charging indicator.
CHARGING PRINCIPLE
Two Stage Method
Charging is performed according to the battery charging characteristics using two-stage method.
- The first stage is named as ‘constant current’: when the battery terminal voltage falls below the pre-set value;
- The second stage is named as ‘constant voltage’: when the battery terminal voltage exceeds the pre-set value, charging current will decrease with the rising of terminal voltage until the pre-set current value is reached, then chargers automatically return to float mode. As soon as charging current value falls below 0.3A and the constant voltage value is reached, the battery is basically charged (charging indicator will extinguish). After that charging current will only neutralize the battery self discharge. Even long-term charging cannot harm the battery, as charger can keep the battery fully charged and so guarantee long lifetime of the battery.
PARAMETERS CONFIGURATION
Items | Contents | 24V |
---|
Input Characteristics
| Nominal AC Voltage| AC(100~277)V
Max. AC Voltage| AC(90~305)V
AC Frequency| 50Hz/60Hz
Max. Current| 2.5A
Efficiency| >75%
Output Characteristics
| No-load Output Voltage| 27.6V±1%
Charging Current| 5A±2%
Max. Output Power| 135W
No-load Loss| <3W
Insulating Property
| Insulating Resistance| Between input and output, input and shell are:
DC 500V 1min, RL≥100MΩ
Insulating Voltage| Between input and output, input and shell are:
AC 1500V 50Hz 1min, Leakage current: IL≦3.5mA
Working Condition
| Working Temperature| (-30~55)°C
Storage Temperature| (-40~85)°C
Working Humidity| 20%RH~93%RH(No condensation)
Shape Structure| Weight| 0.67kg
Dimension| 143mm×96mm×55mm (length×width×height)
OPERATION
Terminal | Function | Description |
---|---|---|
L | AC Terminals | Connect terminals L and N to AC voltage (100~277)V (using |
greater than BVR 1.0mm2 multi-strand copper line.)
N
CF| Charging Fail Alarm
Terminals
| Internal connect to B- via normal close contact of relay with 1A capacity.
B-| Battery Negative| Connect to battery negative using greater than BVR
2.0mm2 multi-strand copper lines.
B+| Battery Positive| Connect to battery positive using greater than BVR
2.0mm2 multi-strand copper lines.
FULL CHARGED| Green LED Indicator| Full Charged Indicator
CHARGING| Red LED Indicator| Charging Indicator
NOTE:
There is a 10A protector tube in the charger output terminal. This
protector will be burned and there is no output voltage if output connection
is reversed. Under this condition, the charger will work after repl acing
protector tube.