Infrared Sauna 2BAHESCSS0008 Fast Charging Power Bank Instruction Manual

June 17, 2024
Infrared Sauna

Infrared Sauna 2BAHESCSS0008 Fast Charging Power Bank

Infrared Sauna 2BAHESCSS0008 Fast Charging Power Bank

Due to our continued product improvement, product illustrated on this instruction manual may vary slightly from the actual product.

Warning

  1. The appliance is to be continuously attended;

  2. The sauna room or cabin is to be inspected before setting the appliance to a standby mode for a delayed start.

  3. Cleaning with steam cleaners, high pressure cleaners and spraying waTer is not allowed.

  4. it is recommended that the infrared cabin should not be used within 24 h after UV radiation exposure from artificial sources or sunbathing;

  5. individuals who may be at risk from hyperthermia, such as individuals suffering from cardiovascular disease, should seek medical advice before use of infrared warming cabins;

  6. when persistent erythema {reddening of the skin lasting more than a day) and netlike color changes persist after regular exposure to infrared radiation, exposure should not be repeated and medical advice should be sought to prevent development of erythema ab igne;

  7. if you are a person with compromised heat pain sensation or under the influence of alcohol or tranquilizers you should not use infrared warming cabins.

  8. a pilot lamp showing that the heater or infrared emitter is switched on is to be installed in the attendant’s room.

  9. This appliance is not intended for use by persons {including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
    Children should be supervised to ensure that they do not play with the appliance.

  10. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.

Important safety guides

Please strictly follow safety precautions when using!

  1. Children must be using the equipment under the core of on adult. For safety, do not p loy with ii ;
  2. Do not insert objects such as fingers or sticks into the heating tube plate to prevent danger ;
  3. Never pour water to the equipment or the heating pipe (board) ;
  4. Do not use or store flammable gas or liquid such as hair spray, oil point, gasoline, etc near the equipment to ovoid fire ;
  5. Do not place items inside or on top of the sauna ;
  6. Do not touch the power control panel and any electrical components with wet hands to prevent electric shock ;
  7. It is forbidden to use the equipment during thunderstorms to prevent electric shock ;
  8. Do not tilt the equipment, do not use sharp objects to strike ;
  9. Shut down the equipment for half on hour of ter 4 hours continuous working ;
  10. Do not operate the equipment in a long-term high temperature environment ;
  11. Use with caution after drinking alcohol ;
  12. Those who have hemophilia or are prone to bleeding should avoid using it ;
  13. Please consult your doctor before using if you Are in period of disease and taking medicine ;
  14. Do not use after intense exercise, wait until the body temperature returns to normal before using ;
  15. If you feel any discomfort, please stop using immediately ;
  16. Mind your head when get in and out of the equipment ;
  17. Do not sleep inside the equipment when ii is working ;
  18. Do not use any both products in the sauna ;
  19. To avoid burns, do not touch the heating element ;
  20. WARNING : Covering the heater or infrared emitter causes fire risk!
  21. If you have any questions, please call the supplier.

Structure of infrared sauna

  1. Duster cover
  2. Speaker
  3. Control box
  4. left board
  5. Control panel
  6. Front board
  7. Handle
  8. Door gloss
  9. Hinge
  10. Ventilation
  11. Temperature sensor
  12. Top board
  13. Backboard
  14. Heater frame
  15. Right board
  16. Bench
  17. Bench front board
  18. Bottom board
  19. Fool rest board
    Structure of infrared sauna

Attention:

  1. The minimum distance between the top of on infrared emitter and the ceiling of the cobin is 100 mm;
  2. The minimum distance between the bottom of on infrared emitter and the floor of the cabin is 40 mm, unless this distance is determined by the construction of the in trored emitter;
  3. The minimum horizontal distance between on infrared emitter and any combustible material of the cabin is 5 mm, unless these distances are determined by the construction of the infrared emitter;
  4. The minimum distance between adjacent infrared emitters is 5 mm.

Installation process

  1. Bottom board

  2. Backboard
    Installation process

  3. Lett board
    Installation process

  4. Right board
    Installation process

  5. Bench front board
    Installation process

  6. Bench
    Installation process

  7. Foot rest board
    Installation process

  8. Front board
    Installation process

  9. Top board
    Installation process

  • The structure may vary from different models. Due to our continued product improvement, product illustrated on this instruction manual may vary slightly from the actual product.

Installation precautions

Lorge plate assembly

  • Suitable for processes 3 and 4 Installation method of the left and right side panels
    Installation precautions

  • Suitable for process 8 Installation method of the front board
    Installation precautions

Installation precautions

Electrical connection

The product is connected to the main power supply through the cable.
the brown core of the cable is connected to the live wire of the main power supply, the blue core is connected to the neutral wire of the main power supply, and the yellow green core is connected to the ground wire of the main power supply

  1. Connection cable

  2. Connection plug
    Installation precautions

Control panel operation

  1. Display screen
    for temperate.time.FM.

  2. Power button
    Touch this key to turn on or turn off it.

  3. Light button
    Touch the key to turn on/off the light inside of cabin.

  4. Music button
    Touch this key to adjust bluetooth.
    MP3 and FM.FM from 85.7-108.0M.

  5. USB function
    Touch this key to start USB function.

  6. Song selection function
    Press key upon the TRACK for last song and key for next one.

  7. Temp control
    Touch the ‘+’and’-‘ button to increase or decrease the temperature. If the ‘heat’ light is on, the temperature setting Wm increase one degree every time the ‘+’ button is pushed. If pressed for three seconds, the selling will increase quickly. Decrease the temperature in the some manner by pressing the •-• button. After the sauna reaches the desired temperature, the ‘heal’ light turns off.
    The Fahrenheit and Centigrade display can be switched:
    press: the temperature button “+” and “.” at the meantime.

  8. Time control
    Touch the ‘+’and’-‘ buttons lo set the timer from 5 to 90 minutes. If pressed for three seconds, the timer will increase quickly. To extend the sauna session. reset the timer again.

  9. Pause/Play
    When music playing in this mode. this key is for pause or play.
    In FM mode. long press for 5 seconds to enter FM stallion search automatic.

  10. Volume control
    Press ‘+’and 1 – 1 to increase or decrease volume.
    Control panel operation

Color light function

5 seconds press on “LIGHT” bullon, shows” 2N” on display.
Short press ” LIGHT “button to change color of LED light.
Press to convert one color at a lime and ii can be cycled
and memorized (LO shade, LI all bright, L2-l 7 corresponding to different colors).
Quick press on TEMP+, can control LED I ON/OFF ( if available).
Quick press on TEMP-, con control LED 2 ON/OFF ( if available).
Quick press on TIME+, can control RGB light ON/OFF ( if available).

Control box

This control box is the control center of sauna room.it is installed on the top board, input/output connections as below.

  1. Main power of sauna room.
  2. Heaters power output cable ( HT1–HT8)
  3. Reading lamp power output cable
  4. Color lamp power output cable(optional)
  5. 12V output
  6. 24V output
  7. If necessary can connect another power box
  8. Temperature sensor connection port
  9. Control panel connecting
  10. Fuse reset(20A)
    Control box

Maintance

Before using

  1. Please be sure to follow the instruction manual before operations ;
  2. Prepare a towel on the seat bench to prevent sweat from dripping onto ii. To avoid affecting the quality and beauty of wood.

After using

  1. Please unplug the power plug in time ;
  2. Open the door to let the heat and humid water vapor dissipate and keep the sauna cabin dry.

Stain on wood

  1. The outer cabin can be wiped with a wrung wet towel;
    The inner cabin can be wiped by small vacuum cleaner.

  2. Do not use organic solvents to decontaminate, such as gasoline, alcohol, etc . wipe the sauna surface;

  3. Do not use sharp objects in sauna cabin to prevent scratching woods.

Stain on glass

  1. Wipe the gloss with soft paper:
  2. Stubborn stains can be wiped with a damp cloth. then dry with a dry cloth;
  3. Do not scratch the surface with a sharp object to prevent scratching the gloss.

Transportation and storage

  1. Avoid water. snow and intense impact during the transportation;
  2. Do not store ii in a humid environment;
  3. The northern climate is relatively dry, often wipe the product with a wrung wet towel:
  4. The climate in the south is relatively humid and can be ventilated and dried frequently.

Troubleshooting

Number Problems Possible reasons Countermeasure
1 Indicator light for power supply not working The connector is not
connected properly Check the connector or replace a new one
No power supply input Chick the circuity ( especially weather there is power

supply input)
Indicator light is broken| Replace the circuity panel
2| Indicator light for function is not working| The heating indicator light is broken| Replace the relevant control panel
The circuit board or components are broken| Replace the circuit board
The temperature sensor is broken| Check if the connect is loosen and replace it
3| Infrared Heater not heating up| The heater is broken| Replace with a new one

Of lhe same specifications

The wire junction or the heater’s wire is loosen| Check and make them tight
The temperature sensor is broken| Check if junction of lhe temperature sensor is loosen and replace it
The circuit board of the relay is not work| Replace the circuit board
4| Odor from lhe sauna| The circuit’s problems| l) There is eyewinker around.

remove it
2) Some heater’s temperature

over high.cut off the power

supply.replace it.
3) Paris on the circ uity is broken

5| Light bulb is not working| Light bulb is burned out| Replace the light bulb
Light bulb wiring is loosen| Replace the tamp holder
Problems with electricity control panel| Repair or replace it
6| Saunois Not Power Up| Power cord is unplug| Plug bock power cord to outlet
Outlet has no power| Check outlet or circuit breaker
Power supply or circuit panel is broken| Replace the power supply or related circuitry board
7| Music Player doesn’t| Power connector is loose or damage| Check connector or replace it
DC power supply is no power to the music player| Check DC power supply wiring or replace the power supply
Music player is defective| Replace the music player
8| Speaker does not work| The speaker is broken| Replace with a new one of the same specifications
The speaker wire is loosen| Reconnect the speaker wire
The power indicator tight for music player is oft| Tum on the switch to start work
9| The temperature display show ”Erl”| NTC open circuit, wire is not well connected| Check and well connect
10| The temperature display show ”Er2″| NTC open circuit| Change Thermostat
l l| The temperature display show ”Er3″| Under -15°| Can’t be functional under too tow ambient temperature
12| The temperature display show ”Er4″| Thermostat breakdown| Change Thermostat

FCC Warning
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

Note: The Grantee is not responsible for any changes or modifications not expressly approved by the party responsible for compliance. such modifications could void the user’s authority to operate the equipment.

The device has been evaluated to meet general RF exposure requirement.
To maintain compliance with FCC’s RF exposure guidelines, the distance must be at least 20 cm between the radiator and your body, and fully supported by the operating and installation

Logo

Read User Manual Online (PDF format)