SmartGen AIN24-2 Analog Input Module User Manual

October 27, 2023
SmartGen

SmartGen AIN24-2 Analog Input Module

SmartGen — make your generator smart

All rights reserved. No part of this publication may be reproduced in any material form (including photocopying or storing in any medium by electronic means or other) without the written permission of the copyright holder.
SmartGen Technology reserves the right to change the contents of this document without prior notice

Table 1 – Software Version

  • Date /Version /Content
  • 2021-10-26 1.0 Original release

Table 2 – Notation Clarification

Symbol Instruction
NOTE Highlights an essential element of a procedure to ensure correctness.
CAUTION Indicates a procedure or practice, which, if not strictly observed,

could result in

damage or destruction of equipment.


WARNING

| Indicates a procedure or practice, which could result in injury to personnel or loss of

life if not followed correctly.

OVERVIEW

AIN24-2 Analog Input Module is a module which has 14-way K-type thermocouple sensor, 5-way resistance type sensor and 5-way (4-20)mA current type sensor. The sampling data are transmitted to the master controller via RS485 port.

PERFORMANCE AND CHARACTERISTICS

  • With 32-bit ARM based SCM, high integration of hardware and more reliable;
  • Must be used with master controller together;
  • RS485 communication baud rate can be set as 9600bps or 19200bps via dial switch;
  • Module address can be set as 1 or 2;
  • Wide power supply range DC(8~35)V, suitable to different battery voltage environment;
  • 35mm guide rail mounting type;
  • Modular design, pluggable terminal, compact structure and easy installation.

TECHNICAL PARAMETERS

Table 3 – Technical Parameters

Item Content
Working Voltage DC(8~35)V, continuous power supply
Power Consumption <0.5W

K-type Thermocouple Measurement

Accuracy

| 1°C
(4-20)mA        Current       Measurement

Accuracy

| Class 1
Case Dimension| 161.6mm x 89.7mm x 60.7mm
Rail Dimension| 35mm
Working Temperature| (-25~+70)°C
Working Humidity| (20~93)%RH
Storage Temperature| (-40~+80)°C
Weight| 0.33kg

WIRE CONNECTION

Table 4 – Terminal Connection

No. Function Cable Size Description
1 B- 1.0mm2 DC power supply negative input.
2 B+ 1.0mm2 DC power supply positive input.
3 NC   No Contact.
4 TR 0.5mm2 Short connect Terminal 4 and Terminal 5 if the matched

resistance is required.

5| RS485 A(+)| ****

0.5mm2

| The RS485 port for communication with master controller.

120Ω shielding wire with its one end grounded is recommended.

6| RS485 B(-)
7| COM (B+)| 1.0mm2| 4-20mA current sensor COM terminal (B+)
8| AIN24| 0.5mm2| 4-20mA current sensor terminal
9| AIN23| 0.5mm2| 4-20mA current sensor terminal
10| AIN22| 0.5mm2| 4-20mA current sensor terminal
11| AIN21| 0.5mm2| 4-20mA current sensor terminal
12| AIN20| 0.5mm2| 4-20mA current sensor terminal
13| SENSOR COM| 0.5mm2| Resistance sensor COM terminal (B+)
14| AUX.SENSOR 19| 0.5mm2| Resistance sensor terminal
15| AUX.SENSOR 18| 0.5mm2| Resistance sensor terminal
16| AUX.SENSOR 17| 0.5mm2| Resistance sensor terminal
17| AUX.SENSOR 16| 0.5mm2| Resistance sensor terminal
18| AUX.SENSOR 15| 0.5mm2| Resistance sensor terminal
19| KIN14+| 0.5mm2| “K-type” thermocouple sensor
20| KIN14-
No.| Function| Cable Size| Description
---|---|---|---
21| KIN13+| 0.5mm2| “K-type” thermocouple sensor
22| KIN13-
23| KIN12+| 0.5mm2| “K-type” thermocouple sensor
24| KIN12-
25| KIN1-| 0.5mm2| “K-type” thermocouple sensor
26| KIN1+
27| KIN2-| 0.5mm2| “K-type” thermocouple sensor
28| KIN2+
29| KIN3-| 0.5mm2| “K-type” thermocouple sensor
30| KIN3+
31| KIN4-| 0.5mm2| “K-type” thermocouple sensor
32| KIN4+
33| KIN5-| ****

0.5mm2

| ****

“K-type” thermocouple sensor

34| KIN5+
35| KIN6-| 0.5mm2| “K-type” thermocouple sensor
36| KIN6+
37| KIN7-| 0.5mm2| “K-type” thermocouple sensor
38| KIN7+
39| KIN8-| 0.5mm2| “K-type” thermocouple sensor
40| KIN8+
41| KIN9-| 0.5mm2| “K-type” thermocouple sensor
42| KIN9+
43| KIN10-| 0.5mm2| “K-type” thermocouple sensor
44| KIN10+
45| KIN11-| 0.5mm2| “K-type” thermocouple sensor
46| KIN11+
 | ****



SWITCH

| The master controller can connect to two AIN24-2 modules at the same time.

Address selection: It is module 1 when the switch 1 is connected to 12 while module 2 when connect to ON position.

Baud rate selection: It is 9600bps when the switch 2 is connected to 12

while 19200bps when connect to ON position.

 | POWER| Power supply normal indicator;

It is flashing when the communication is abnormal for over 10s.

ELECTRICAL CONNECTION DIAGRAM

CASE DIMENSIONS

TROUBLESHOOTING

Problem Possible Solution
Controller    no    response                    with power Check power

voltage;

Check controller connection wirings; Check DC fuse.

RS485 communication failure| Check if RS485 wires are connected correctly.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>