Installation Instructions Flex and Plug Method
-
This product should only be installed by a licenced electrician in compliance with AS/NZS3000 (current edition) or other regulations that may be relevant to the situation.
-
Ensure desired location is suitable and clear of all obstructions
-
Cut hole with a suitable tool
(Std cut-out 65-92mm. Compact: 65-80mm.) -
After ensuring the circuit is isolated, terminate wiring
in an approved manner. -
Insert the supply cord plug into the socket.
-
Hold back the spring clips and insert downlight into opening.
-
Release clips and centre fixture in the opening.
-
Energise and Test.
Installation Instructions Direct Connection Method
-
This product should only be installed by a licenced electrician in compliance with AS/NZS3000 (current edition) or other regulations that may be relevant to the situation.
-
Ensure desired location is suitable and clear of all obstructions
-
Cut hole with a suitable tool
(Std cut-out 65-92mm. Compact: 65-80mm.) -
Remove cover from incoming end of driver and remove flex.
-
After ensuring the relevant circuit is isolated terminate the wiring in an approved manner.
-
Ensure cable clamp is positioned correctly to secure the sheathing of the incoming cables. NOT the primary insulation on the wires.
-
Replace terminal cover.
-
Hold back the spring clips and insert downlight into opening.
-
Release clips and centre fixture in the opening.
-
Energise and Test.
Warranty
Subject to the terms and conditions outlined in the warranty statements
displayed on the Lumex website
(lumexlighting.com.au) or those laid down in
consumer law, Lumex LED fixtures are warranted against failure due to a
manufacturing defect for a period of seven (7) years or 35,000 operational
hours from the date of purchase, whichever is the lesser. In standard warranty
applications, Lumex undertake to repair or replace the product. Refer to the
detailed warranty statements posted on the website for clarification. The
Lumex document part number is MMS-RWS
Clearance from Combustible Materials and Insulation
This product has been tested to
the relevant sections of AS NZS 60598.2.2-2016 and found to qualify for the
rating IC-4, suitable to be abutted against and covered by normally flammable
materials, including building insulation, and that it has a restricted airflow
between the illuminated space and the space where it is located.
Refer to the detailed recommended spacing below.
Dimension | Clearance |
---|---|
A- Clearance above luminaire | 0mm |
B- Side clearance to combustible building element | 0mm |
C- Side clearance to bulk thermal insulation | 0mm |
D- Clearance to auxiliary equipment (LED driver) | 0mm |
Reminder: AS/NZS3000:2007 Amendment 2, Clause 4.5.2.3.2 requires a permanent and legible warning sign be installed in an accessible space where recessed luminaries are installed. This sign must be adjacent to the access panel and meet specific requirements. Compliant signs are available from electrical wholesalers. – part number MMS-RWS
Optional fixture faces
Décor Plus standard fixture is 110mm diameter Universal. There are also four optional fixture faces:
Compact
- 90mm diameter faceplate
- Cut-out 65-80mm
- To order add [-FC] to standard equivalent
Low glare
- 110mm diameter recessed faceplate
- Standard cut-out
- To order add [-FG] to standard equivalent
Square
- 110mm square faceplate
- Standard cut-out
- To order add [-FS] to standard equivalent
Changing fixture faces
- Décor Plus fixture faces can be removed from the lamp module by twisting counterclockwise. When they hit the stop the lamp module can be remove from the fixture face.
- Replace the fixture face is a simple reverse of the removal process.
CUSTOMER SERVICE
+61 (03) 9790 8999
verbatimlighting.com.au
References
- Verbatim Lighting | Lumex | Forlite | Commercial Lighting Solutions
- Verbatim Lighting | Lumex | Forlite | Commercial Lighting Solutions
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>