LUMEX LL2D23GSX USA Stock Class 2 LED Drivers Instruction Manual
- June 3, 2024
- LUMEX
Table of Contents
LL2D23GSX USA Stock Class 2 LED Drivers
Instruction Manual
Product Details
- Class II driver, without FG, flicker free
- Built in active PFC function, high PF, low THD
- Standby power consumption <0.5W to turn off dimmable port
- Supporting multi-power supply synchronous dimming
- connected in parallel
- Suitable for indoor LED lighting applications
Model Number| Input Voltage| Input Current| Output Voltage| Output Current|
Output Power
---|---|---|---|---|---
LL2D23GSX| 200-240Vac| 0.3A Max.| 3-42Vdc| 600mA| 25.2W
LT2D26GSX| 200-240Vac| 0.3A Max.| 3-42Vdc| 700mA| 29.4W
LT2D28GSX| 200-240Vac| 0.3A Max.| 3-42Vdc| 750mA| 31.5W
LT2D30GSX| 200-240Vac| 0.3A Max.| 3-42Vdc| 800mA| 33.6W
LT2D33GSX| 200-240Vac| 0.3A Max.| 3-42Vdc| 850mA| 35.7W
LT2D34GSX| 200-240Vac| 0.3A Max.| 3-42Vdc| 900mA| 37.8W
LT2D37GSX| 200-240Vac| 0.3A Max.| 3-42Vdc| 950mA| 39.9W
LT2D38GSX| 200-240Vac| 0.3A Max.| 3-42Vdc| 1000mA| 42W
LT2D40GSX| 200-240Vac| 0.3A Max.| 3-42Vdc| 1050mA| 42W
LT2D45GSX| 200-240Vac| 0.3A Max.| 3-42Vdc| 1100mA| 41.8W
X in model number can be ‘1’ or ‘D’ where GS1 means 1-10V dimmable and GSD means DALI dimmable
Mechanical Specifications
INSTALLATION INSTRUCTIONS
- Power supplies must be installed by a qualified electrician who is familiar with the installation and operation manual.
- Driver comes pre installed with cable and plug, dimming cable and DC cable and plug for connecting the products.
- Ensure power is switched off before connecting the drivers to the products.
- Connect the driver DC cable to the LED compatible product.
- Connect the dimming
+’ and
-‘ cable to the dimming controls. - Connect the AU plug to power supply.
Attention!
- To be only installed or replaced by a qualified electrician in accordance with AS/NZS 3000 wiring rules.
- Ensure the main switch is off before connecting the product to the power supply.
- If the external flexible cable or wire is damaged, it must only be exchanged by the supplier, its agent or other similar qualified personals.
- Modification or disassembly of this product will void any warranty.
- Do not attempt to open the cover or change any settings inside as it can damage the product and void the warranty.
- Drivers to be used with Lumex products it is supplied with.
- Please note the minimum clearance distances as given in the image (a) below.
- Please keep this manual for future reference.
Minimum Clearance distance
Refer to below Image for minimum clearance distance required
Note:
a= Min 20mm
b= Min 20mm
c= Min 10mm
a=b=Min 20mm:The Minimum clearance distance from the side of the luminaire to
any normally flammable building element, the insulation distance between a and
b is the same.
d: The minimum clearance distance from the top of the luminaire to any
normally flammable building element, the top also keeps a “distance d” from
the insulation layer of the building.
WARNING
-
FELV terminals marked ” Risk of electric shock” are not safe to touch
-
Circuits connected to any FELV control terminal shall be insulated for the LV supply voltage of the control gear and any terminals connected to the FELV circuit shall be protected against accidental contact.