elinchrom EL20616.1 ELC Pro HD 1000 Flash Head User Guide
- June 4, 2024
- elinchrom
Table of Contents
Elinchrom EL20616.1 ELC Pro HD 1000 Flash Head Quick Start
User Guide
Quick Start Guide
DISPLAY PANEL – DASHBOARD
- EL-Skyport synchronisation normal/ speed
- EL-Skyport Frequency channel
- EL-Skyport Group number
- Photocell status
- Ready beep
- Power in J
- Flash duration in s
- Flash function
- Flash function value
- Increase I. f-stop (R)
- Open flush test (5)
- Decrease I. f-stop (L)
- Recycling mode
- Power in f-stop equivalent
DISPLAY PANEL – MAIN MENU
- Menu title
- Menu selected
- Menu exit (back to dashboard) (R)
- Enter (S)
- Back (L)
Added possibility to enable/disable flash before ready.
- When “ENABLED”, the Strobo mode will work at the fastest possible speeds.
- When “DISABLED”, flashes can be only released when the charge level is reached. The priority is on accurate exposures.
Activation:
When the unit is OFF, press and hold ON + knob button (S) until the message
“ENABLED” is shown, to return to “DISABLED” repeat the programming
procedure,the show value is automatically saved as the standard setting for
the unit.
DISPLAY PANEL – MODELING LAMP
- Setting title
- Modelling lamp status
- Back to the dashboard (R)
- Visual Flash Confirmation function (S)
- Proportional modelling lamp setup (L)
- Proportional modelling lamp value
- Visual Flash Confirmation status
- Modelling lamp power in f-stop
KNOB COLOR INFO
Knob Button (S)
Display | Description |
---|---|
Green | Ready |
Green blinking | Discharging |
Orange | Charging |
Red blinking | Flashing before 100% ready |
Red breathing | Stand by |
ELINCHROM STUDIO APP / SOFTWARE
Speed up your workflow with the Elinchrom App / Software and take control of your light wherever you are.
- Control up to 20 units
- Save and reload presets
- Edit a friendly name
- Change group by drag & drop
Available on macOS, Windows, Android and iOS
www.elinchrom.com/range/app- software/
ERROR MANAGEMENT
Error
|
Description
|
Solution
---|---|---
1
| ****
Capacitor over voltage
| Switch the unit off, wait 2 minutes and switch the unit on again. If the error shows up again the unit requires a check-up at an authorized Elinchrom service centre.
2
| ****
Overheat
| Wait until the unit has cooled down. The unit will switch back to normal
operation as soon as the temperature decreases to a normal working level.
3| Discharge error| ** Switch the unit off, wait 2
minutes and switch the unit on again. If the error shows up again the unit
requires a check-up at an authorized Elinchrom service centre.
4| Charge timeout error
******5
6
| Zero detect fault __
Charge hold error
8| Fan error
10| Supply input voltage too high| ** The unit has detected a
main supply fault. Please check the mains/battery supply. It could be not
working correctly.
11| Supply input voltage too low
12| Supply under voltage detected until the charge
15| The temperature sensor “Heat Sink” is not connected|
** Switch the unit off, wait 2 minutes and switch the unit on again.
If the error shows up again the unit requires a check-up at an authorized
Elinchrom service centre.
16| The temperature sensor “Front” is not connected
17| Temperature sensor “Charge” not connected
20| Power Board not connected/found
24
| Capacitor voltage symmetry error| Switch the unit off, wait 10 minutes and switch the unit on again. If the error shows up again the unit requires a check-up at an authorized Elinchrom service centre.
28
| ****
Flash tube afterglow
| Switch the unit off, wait 2 minutes and switch the unit on again. If the error shows up again the unit requires a check-up at an authorized Elinchrom service centre.
Download the ELC Pro HD User Guide
www.elinchrom.ch/support Download the
ELC Pro HD User Guide
** www.elinchrom.com**
Elinchrom is a registered trademark of ELINCHROM LTD, RENNES, SWITZERLAND
QSG ELC PRO HD – 73019 – 06.2022
Av. de Longemalle 11, CH-1020 Renens, Switzerland
Tel. : + 41 21 637 26 77 / e-mail:
support@elinchrom.ch