elinchrom EL20839.2 Lighting Kit D Lite User Guide

June 15, 2024
elinchrom

Quick Start Guide
D-LiTE RX 2/4

D-Lite RX 2/4 – 12.2022

CONTROL PANEL

elinchrom EL20839 2 Lighting Kit D Lite - CONTROL
PANEL

FUNCTION

Programming

Power Down / Up
Ready charge beep On / Off
Test Manual trigger
Photocell On / Off
Eye cell pre-flash sensor Press 4s On
Modelling lamp prop/min/max/off/
Master reset  Press together and turn on the unit

SETTING

Enter into menu
Toggle sub-menu

Visual flash control
Set Modelling Lamp to turn off during recharge| Press
2s
| | Set with|
---|---|---|---|---
Proportional modelling lamp set up Set Modelling  Lamp to 50% on 250ws Head for proportionality with 500ws Head| Set with|
Charge ready beep set-up
Set ready beep between 70-490 ms| Press
2s| | Set with
| Between 70-490 ms
Red eye pre-flash recognition| Press
4s| | Set with
| Auto count the flash
No pre-flash
6 pre-flash
EL-Skyport activation| Press
together
| | Set with
| Off
Normal mode
Speed mode
EL-Skyport group settings| Set with
| Group 1 to 4
EL-Skyport frequency channel settings| Set with
| Channel 1 to 8
Power & modelling steps set-up
Set power change to steps 1/10, 5/10 or up to 1/1 f-stop| Set with
| 1 stop
1/10
5/10
Master reset|  Switch off the unit than press together and turn on again

Changes are saved automatically after 4s

DECLARATION OF CONFORMITY USA & CANADA

This device complies with Part 15 of the FCC Rules and with Industry Canada licence-exempt RSS standard(s).
Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
This product complies with the Canadian ICES-003 Class B specifications.

Radiation Exposure Statement
This equipment complies with portable RF exposure limit in Canada and the USA set forth an uncontrolled environment and is safe for intended operation as described in this manual. Further RF exposure reduction can be achieved if the product can be kept as far as possible from the user body.

FCC Class B Compliance note
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/television technician for help.

Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.
This device is limited to operation on permissible Part 15 frequencies, and is does not have the ability to be configured by end users or professional installers to operate outside the authorized bands.

Product name: D-Lite RX 2 / D-Lite RX 4
Trade name: ELINCHROM
Model number(s): 20486.1 / 20487.1
Name of responsible party: Elinchrom LTD

Av. de Longemalle 11
1020 Renens / Switzerland

TROUBLESHOOTING

E1| Overvoltage detected| Switch unit OFF, wait 2 minutes and switch unit ON again. If the error shows up again the unit requires a check up at the Elinchrom service centre
---|---|---
E2| Overheating| Wait until the unit has cooled down. The unit will switch back to normal operation as soon as temperature decreases to normal working level.
E3| Auto dump function fault| The Unit has detected a time out in the ADF mode. Switch the unit OFF, wait 2 minutes and switch the unit ON again; use the Test release button for power reduction. If the error shows up again the unit requires a check up at the Elinchrom service centre.
E4| Charge fault| Unit has detected a time out during recharging. Switch unit OFF, wait 2 minutes and switch unit ON again. If the error shows up again the unit requires a check up at the Elinchrom service centre.
E5| Mains supply fault| Unit has detected a mains supply fault. Check your mains cord and mains installation sockets. Switch unit OFF, wait 2 minutes and switch unit ON again. If the error shows up again the unit requires a check up at the Elinchrom service centre.
E8| Fan management fault| Unit has detected a FAN management problem due to overheating. Wait until the unit has cooled down. Check if the FAN is blocked. If the error shows up again the unit requires a check up at the Elinchrom service centre.

DOWNLOAD THE USER GUIDE

Obtain the complete user guide using this link:|

www.elinchrom.com/support/download-center/

![elinchrom EL20839 2 Lighting Kit D Lite - QR Code 1](https://manuals.plus/wp-content/uploads/2023/12/elinchrom-EL20839-2-Lighting-Kit-D-Lite-QR-Code-1.jpg)  

---|---

DOWNLOAD CONFORMITY

Find your declaration for EC and USA & Canada conformity here:|

www.elinchrom.com/support/download-center/

---|---

 **Please check all security documents before use !**
No guarantee for misprints - Elinchrom LTD 
Av. de Longemalle 11, CH-1020 Renens, Switzerland,
E-mail: [[email protected]](mailto:[email protected])
[www.elinchrom.com](http://www.elinchrom.com)

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

elinchrom User Manuals

Related Manuals