elinchrom EL20839.2 Lighting Kit D Lite User Guide
- June 15, 2024
- elinchrom
Table of Contents
Quick Start Guide
D-LiTE RX 2/4
D-Lite RX 2/4 – 12.2022
CONTROL PANEL
FUNCTION
Programming
Power | Down / Up | |
---|---|---|
Ready charge beep | On / Off | |
Test | Manual trigger | |
Photocell | On / Off | |
Eye cell pre-flash sensor | Press 4s | On |
Modelling lamp | prop/min/max/off/ | |
Master reset | Press together | and turn on the unit |
SETTING
Enter into menu
Toggle sub-menu
Visual flash control
Set Modelling Lamp to turn off during recharge| Press
2s
| | Set with|
---|---|---|---|---
Proportional modelling lamp set up Set Modelling Lamp to 50% on 250ws Head
for proportionality with 500ws Head| Set with|
Charge ready beep set-up
Set ready beep between 70-490 ms| Press
2s| | Set with
| Between 70-490 ms
Red eye pre-flash recognition| Press
4s| | Set with
| Auto count the flash
No pre-flash
6 pre-flash
EL-Skyport activation| Press
together
| | Set with
| Off
Normal mode
Speed mode
EL-Skyport group settings| Set with
| Group 1 to 4
EL-Skyport frequency channel settings| Set with
| Channel 1 to 8
Power & modelling steps set-up
Set power change to steps 1/10, 5/10 or up to 1/1 f-stop| Set with
| 1 stop
1/10
5/10
Master reset| Switch off the unit than press together and turn on again
Changes are saved automatically after 4s
DECLARATION OF CONFORMITY USA & CANADA
This device complies with Part 15 of the FCC Rules and with Industry Canada
licence-exempt RSS standard(s).
Operation is subject to the following two conditions: (1) this device may not
cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
This product complies with the Canadian ICES-003 Class B specifications.
Radiation Exposure Statement
This equipment complies with portable RF exposure limit in Canada and the USA
set forth an uncontrolled environment and is safe for intended operation as
described in this manual. Further RF exposure reduction can be achieved if the
product can be kept as far as possible from the user body.
FCC Class B Compliance note
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more
of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/television technician for help.
Any changes or modifications not expressly approved by the party responsible
for compliance could void the user’s authority to operate this equipment.
This device is limited to operation on permissible Part 15 frequencies, and is
does not have the ability to be configured by end users or professional
installers to operate outside the authorized bands.
Product name: | D-Lite RX 2 / D-Lite RX 4 |
---|---|
Trade name: | ELINCHROM |
Model number(s): | 20486.1 / 20487.1 |
Name of responsible party: | Elinchrom LTD |
Av. de Longemalle 11
1020 Renens / Switzerland
TROUBLESHOOTING
E1| Overvoltage detected| Switch unit OFF, wait 2 minutes and
switch unit ON again. If the error shows up again the unit requires a check up
at the Elinchrom service centre
---|---|---
E2| Overheating| Wait until the unit has cooled down. The unit will
switch back to normal operation as soon as temperature decreases to normal
working level.
E3| Auto dump function fault| The Unit has detected a time out in
the ADF mode. Switch the unit OFF, wait 2 minutes and switch the unit ON
again; use the Test release button for power reduction. If the error shows up
again the unit requires a check up at the Elinchrom service centre.
E4| Charge fault| Unit has detected a time out during recharging.
Switch unit OFF, wait 2 minutes and switch unit ON again. If the error shows
up again the unit requires a check up at the Elinchrom service centre.
E5| Mains supply fault| Unit has detected a mains supply fault.
Check your mains cord and mains installation sockets. Switch unit OFF, wait 2
minutes and switch unit ON again. If the error shows up again the unit
requires a check up at the Elinchrom service centre.
E8| Fan management fault| Unit has detected a FAN management
problem due to overheating. Wait until the unit has cooled down. Check if the
FAN is blocked. If the error shows up again the unit requires a check up at
the Elinchrom service centre.
DOWNLOAD THE USER GUIDE
Obtain the complete user guide using this link:|
www.elinchrom.com/support/download-center/
![elinchrom EL20839 2 Lighting Kit D Lite - QR Code 1](https://manuals.plus/wp-content/uploads/2023/12/elinchrom-EL20839-2-Lighting-Kit-D-Lite-QR-Code-1.jpg)
---|---
DOWNLOAD CONFORMITY
Find your declaration for EC and USA & Canada conformity here:|
www.elinchrom.com/support/download-center/
---|---
**Please check all security documents before use !**
No guarantee for misprints - Elinchrom LTD
Av. de Longemalle 11, CH-1020 Renens, Switzerland,
E-mail: [support@elinchrom.ch](mailto:support@elinchrom.ch)
[www.elinchrom.com](http://www.elinchrom.com)
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>