GENERAL INFORMATION

Safety instructions
DANGER
Indicates a danger which may result in immediate death or serious injury.

WARNING
Indicates a danger which may result in death or serious injury.

PRECAUTION
Indicates a danger which may result in minor or moderate injury.

CAUTION
Indicates a danger which may result in damage to or destruction of the product.

PRIOR INFORMATION

Field of application

The Sonesse 40 drives are designed to drive all types of interior blinds except pantographs. The installer, who must be a motorisation and home automation professional, must ensure that the motorised product is installed in accordance with the standards in force in the country in which it is installed such as EN 13120 relating to interior blinds.

Liability

Before installing and using the drive, please read these instructions carefully.
In addition to the instructions provided in this guide, please also comply with the instructions provided in the attached Safety instructions document.
The drive must be installed by a home motorisation and automation professional, in accordance with Somfy’s instructions and the applicable regulations in the country of installation.
Any operation of the drive outside the field of application described above is prohibited. Such use, and any failure to comply with the instructions given in this guide and in the attached Safety instructions document, absolves Somfy of any liability and invalidates the warranty.
After installing the drive, the installer must inform his customers of the operating and maintenance conditions for the drive and must provide them with the operating and maintenance instructions, and the attached Safety instructions document. Any After-Sales Service operation on the drive must be performed by a home motorisation and automation professional.
Never begin installing without first checking the compatibility of this product with the associated equipment and accessories. If in doubt when installing this product and/or to obtain additional information, contact a Somfy representative or visit the website www.somfy.com.

INSTALLATION

WARNING

  • These instructions are mandatory for the home motorisation and automation professional installing the drive.
  •  Comply with current standards and legislation in the country of installation.

CAUTION

  • Never drop, knock or puncture the drive or immerse it in liquid.
  •  Install an individual control point for each drive.
  • To insure optimized silent operation, the gaps between the drive, the accessories, the tube and the tube end piece must be minimized.
Assembly

Replace the head cover with a different color (Optional)

  1. Remove the screw.
  2. Replace the cover with a new cover.
  3. Screw the cover at 0,4 N·m.

NOTICE
Head has interchangeable covers to fit with the fabric.

Preparing the drive
Check that the inner diameter of the motorised product’s tube is greater than 37 mm.

  1. Fit the accessories required to integrate the drive into the winding tube: fit the crown (a) and the drive wheel (b) to the drive.
  2. Measure the length (L) between the inner edge of the drive head and the rim of the drive wheel.

Preparing the tube

  1. Cut the winding tube to the required length, depending on the motorised product.
  2. Deburr the winding tube and remove the swarf.
  3. For winding tubes which are smooth inside, cut a notch with the following measurements: l = 7 mm, L = 10 mm.

Assembling the drive-tube

  1. Slide the drive into the winding tube. For winding tubes with a smooth interior, position the cut notch on the crown.
  2. The drive wheel must be locked in place to prevent any movement in the  winding tube: This can be achieved by fastening the winding tube to the drive wheel using 4 self-tapping screws, Ø 5 mm, or 4 steel pop rivets, Ø 4.8 mm, placed between 5 mm and 15 mm from the outer edge of the drive wheel, regardless of the winding tube.

CAUTION
The screws or pop rivets must only be fastened onto the drive wheel and not on the drive.

Installing the drive-tube assembly

  • The motorised product must not be compressed between the brackets.
  • Do not use the plastic cross without the metal bracket adapter.

The drive can be fixed directly onto the drive bracket (the screw holes are spaced 29 mm apart). Use 2 screws 4 x 8 mm delivered with the motor. A manual tightening torque of 1.5 N·m is recommended.
Drive plates are also available in the current catalogue (Select the correct drive plate adapted to the bracket and check the torque requirements in the system). Use the 2 screws 3  x  6  mm delivered with the motor plate. A manual tightening torque of 0.6 N·m is recommended.

  1. Screw the bracket adapter to the drive head.
  2.  Install and fix the drive-tube assembly onto the end bracket (c) and onto the drive bracket (d).

CAUTION

  1. Ensure that the drive-tube assembly is secured onto the end bracket. This operation prevents the tube-drive assembly from coming out of the end bracket attachment.
  2. Light gap reduced: Do not pinch cables or be careful they are not in contact with moving parts.
  3. Do not let the drive-tube hanged by only one side.
Wiring

Power wiring
PRECAUTION

  • Cables which pass through a metal wall must be protected and isolated using a sheath or sleeve.
  • Secure cables to prevent any contact with moving parts.
  • The drive cable cannot be removed. If it is damaged, return the drive to the After-Sales department.
  • Leave the drive power supply cable accessible: it must be easily replaceable.
  • Connection must be done in a junction box.
  1. Switch off the power supply.
  2. Connect the drive according to the information in the table below:

Data wiring

  • There is a RJ45 female to female coupler provided with the drive to add easily an extension cable.
  • Make sure the data cable is not pinched or damaged during the installation of the drive/tube onto the end bracket.

Connect the data cable to the drive according to the information in the tables below.

  • + RS485 5: Not connected**

  •  – RS485 6: Not connected**

  • Not connected 7: Not connected

  • Power out * 8: GND

  • The LSU Power Out characteristics comply with the following voltage and current characteristics: 8 V min – 50 mA max. ** If connected, the drive can be damaged.

NOTICE
The wiring guide is available for download at https://www.somfy.com/projects/downloads

Commissioning

The drive has 2 blinds profile inside:-

  • Roller mode (to control all blinds except Venetians).
  • Venetian mode.

Two tools are available to set the drive.

  • RS485 SETTING TOOL: Connect the RS485 SETTING TOOL to the drive switch on and follow the instruction on the RS485 SETTING TOOL.
    NOTICE

  • Venetian mode allows to manage the tilt and the lift position. It is not possible to set the drive-in venetian mode through the RS485 SETTING TOOL.

  • When setting end limits, take care that the load bar remains free at upper end Limit.

  • SDN Config Tool: Somfy Digital Network Configuration Tool.
    NOTICE
    The SDN Config Tool is available for download at https://www.somfy.com/projects/downloads NOTICE
    The different versions of which are available in the current Somfy catalogue.

Tips and advice on installation

Questions about the drive?

somfy-Sonesse-40-Wirefree-Rechargeable-2

USE AND MAINTENANCE

NOTICE
This drive does not require any maintenance operations.
CAUTION

  • For the safety of goods and people, Somfy drives are equipped with thermal protection that will trigger the drive stops in the event of overheating.
  • Repeated activation of this protection can degrade drive performance.
  • If the drive goes to thermal protection, please check your installation and check that the drive is rated for the intended use.
  •  A normal installation is not expected to trigger this protection.

NOTICE
When some functions require a power cut, the power cut is only taken into account if it lasts more than 10 seconds.

Operation

To control the drive, please refer to the installation instructions of the used control point.

PROG button
  • In user mode, control drive UP / Stop / Down / Stop Short press (< 1,5 s)
  • Post node ID on the network Press until first feedback (about 2 s)
  • Reset drive to factory Press until third feedback (about 12 s)
LED feedback

somfy-Sonesse-40-Wirefree-Rechargeable-1

TIPS AND ADVICE ON OPERATION

Questions about the drive?

Observations : Possible causes : Solutions

  • The motorised product does not work. The drive is in thermal protection mode. Wait for the drive to cool down to
    restart the drive.
    Do not touch the drive: risk of burns.

NOTICE
If the motorised product still does not work, contact a drive and home automation professional.

TECHNICAL DATA

  • Power supply 120 V 〜 60 Hz 220 V 〜 60 Hz 230 V 〜 50 Hz
  • Operating temperature 0° to 60° C 0° to 60° C 0° to 60° C
  • Index protection rating IP31 IP31 IP31
  • Safety level Class II Class II Class II
  • Power wiring Open leads Open leads Open leads
  • Datas wiring RJ45 Male RJ45 Male RJ45 Male
  • Duty cycle Time ON: 40 s
  • Time OFF: 60 s 4 min.

NOTICE
For additional information on the technical data for this drive, contact your Somfy representative.
We care about our environment. Do not dispose of the appliance with usual household waste. Give it to an approved collection point for recycling.
SOMFY ACTIVITES SA, 74300 CLUSES FRANCE as manufacturer hereby declares that the drive covered by these instructions when marked for input voltage 230V~50Hz and used as intended according to these instructions, is in compliance with the essential requirements of the applicable European Directives and in particular of the Machinery Directive 2006/42/EC and EMC Directive 2014/30/EU.
The full text of the EU declaration of conformity is available at www.somfy.com/ce.
Philippe Geoffroy, Approval manager, acting on behalf of Activity director, Cluses, 05/2021.
Somfy limited, Yeadon LS19 7ZA UK hereby declares that the drive covered by these instructions when marked for input voltage 230V~50Hz and used as intended according to these instructions, is in compliance with UK legislation of Machinery safety regulations S.I.2008 N°1597. The full text of the UKCA declaration of conformity is available at www.somfy.co.uk.
Steven MONTGOMERY, Managing Director Somfy Ltd UK & Ireland, Yeadon, 05/2021.