MW LRS-450 series 450W Single Output Switching Power Supply User Manual

August 29, 2024
MW

MW LRS-450 series 450W Single Output Switching Power Supply

Product Specifications

MODEL| DC VOLTAGE| RATED CURRENT| CURRENT RANGE| RATED POWER| RIPPLE & NOISE (max.)
---|---|---|---|---|---
LRS-450-5| 5V| 75A| 0 – 75A| 375W| 200mVp-p
LRS-450-12| 12V| 37.5A| 0 – 37.5A| 450W| 200mVp-p
LRS-450-15| 15V| 30A| 0 – 30A| 450W| 200mVp-p
LRS-450-24| 24V| 18.8A| 0 – 18.8A| 451.2W| 240mVp-p
LRS-450-36| 36V| 12.5A| 0 – 12.5A| 450W| 360mVp-p
LRS-450-48| 48V| N/A| N/A| N/A| N/A

Product Usage Instructions

Power Supply Setup:
Ensure the input voltage is within the specified range mentioned in the user manual.

Connecting to Devices:
Connect the output terminals of the power supply to the corresponding input terminals of your device.

Powering On:
Switch on the power supply using the designated power switch.

Monitoring:
Monitor the output voltage and current to ensure they meet the requirements of your device.

Frequently Asked Questions (FAQ)

  • Can I use the LRS-450 series power supply for outdoor applications?
    The power supply is designed for indoor use only and should not be exposed to outdoor conditions.

  • What is the typical efficiency of the LRS-450 series power supply?
    The typical efficiency ranges from 87% to 92%, depending on the specific model.

  • How do I select the appropriate DC voltage output for my device?
    Choose the DC voltage output that matches the requirements of your device from the available options provided in the specifications table.

Features

  • MEANWELL Patent Number :ZL202220241473.0
  • AC input range selectable by switch
  • Withstand 300VAC surge input for 5 second
  • Protections: Short circuit / Overload / Over voltage / Over temperature
  • Forced air cooling
  • Built-in cooling Fan ON-OFF control
  • 1U low profile
  • Withstand 5G vibration test
  • High operating temperature up to 70°C
  • Operating altitude up to 5000 meters (Note.10)
  • 3 years warranty
  • MTBF>1KK hrs

Applications

  • Industrial automation machinery
  • Industrial control system
  • Mechanical and electrical equipment
  • Electronic instruments, equipments or apparatus

GTIN CODE

MW Search: https://www.meanwell.com/serviceGTIN.aspx

Description

LRS-450 series is a 450W single-output enclosed type power supply with 35mm of low profile design. Adopting the input of 115VAC or 230VAC (select by switch), the entire series provides an output voltage line of 5V, 12V, 15V, 24V, 36V and 48V. In addition to the high efficiency up to 92%, with the built-in long life fan LRS-450 can work under -20~+70°C with full load. LRS-450 has the complete protection functions and 5G anti-vibration capability; It is complied with complete international safety regulations LRS-450 series serves as a high price-to-performance power supply solution for various industrial applications.

Model Encoding

SPECIFICATION

MODEL| LRS-450-5| LRS-450-12| LRS-450-15| LRS-450-24| LRS-450-36| LRS-450-48
---|---|---|---|---|---|---

OUTPUT

| DC VOLTAGE| 5V| 12V| 15V| 24V| 36V| 48V
RATED CURRENT| 75A| 37.5A| 30A| 18.8A| 12.5A| 9.4A
CURRENT RANGE| 0 ~ 75A| 0 ~ 37.5A| 0 ~ 30A| 0 ~ 18.8A| 0 ~ 12.5A| 0 ~ 9.4A
RATED POWER| 375W| 450W| 450W| 451.2W| 450W| 451.2W
RIPPLE & NOISE (max.) Note.2| 200mVp-p| 200mVp-p| 200mVp-p| 240mVp-p| 360mVp-p| 360mVp-p
VOLTAGE ADJ. RANGE Note.3| 4.75 ~ 5.5V| 11.4 ~ 13.2V| 14.25 ~ 16.5V| 22.8 ~ 26.4V| 34.2 ~ 39.6V| 45.6 ~ 52.8V
VOLTAGE TOLERANCE Note.4| ±2.0%| ±1.5%| ±1.0%| ±1.0%| ±1.0%| ±1.0%
LINE REGULATION Note.5| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
LOAD REGULATION Note.6| ±2.0%| ±1.0%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
SETUP, RISE TIME Note.7| 1500ms, 50ms/230VAC 1500ms,50ms/115VAC at full load
HOLD UP TIME (Typ.)| 16ms/230VAC        12ms/115VAC at full load

INPUT

| VOLTAGE RANGE Note.8| 90 ~ 132VAC / 180 ~ 264VAC by switch 255 ~ 370VDC (swith on 230VAC)
FREQUENCY RANGE| 47 ~ 63Hz
EFFICIENCY (Typ.)| 87%| 90%| 90%| 91%| 92%| 92%
AC CURRENT (Typ.)| 10A/115VAC           6A/230VAC
INRUSH CURRENT (Typ.)| 35A/115VAC          60A/230VAC
LEAKAGE CURRENT| <2mA / 240VAC

PROTECTION

(Note.9)

|

OVER LOAD

| 105 ~ 150% rated output power
Constant current limiting, unit will shutdown after 3 sec. re-power on to recover
OVER VOLTAGE| 5.75 ~ 6.75V| 13.8 ~ 16.2V| 18 ~ 21V| 27.6 ~ 32.4V| 41.4 ~ 48.6V| 55.2 ~ 64.8V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE| Shut down o/p voltage, re-power on to recover

FUNCTION

| FAN ON/OFF CONTROL

(Typ.)

| RTH3≧50℃ FAN ON, ≦40℃ FAN OFF

ENVIRONMENT

| WORKING TEMP.| -20 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
OVER VOLTAGE CATEGORY| Ⅲ: According to EN61558, EN50178, EN60664-1, EN62477-1; altitude up to 2000 meters

SAFETY

|

SAFETY STANDARDS

| BS IEC/UL 62368-1, EAC TP TC 004,KC62368-1(except for 5V), BIS IS13252(Part1):2010/IEC60950-1: 2005(NOTE 13),BSMI CNS15598-1,GB 4943.1,BS EN/EN61558-1,BS EN/EN61558-2-16 approved,

Designed by AS/NZS 61558.1/2.16, AS/NZS 62368.1

WITHSTAND VOLTAGE| I/P-O/P:3.75KVAC  I/P-FG:2KVAC  O/P-FG:0.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC / 25℃/ 70% RH
EMC EMISSION| Compliance to EAC TP TC 020, BSMI CNS15936,KC KSC 9832, KSC 9835
EMC IMMUNITY| Compliance to EAC TP TC 020,KC KSC 9832, KSC 9835

OTHERS

| MTBF| 1508.9K hrs min. Telcordia SR-332(Bellcore) ;  252.2K hrs min. MIL-HDBK-217F (25℃)
DIMENSION| 22512435mm (LWH)
PACKING| 0.85Kg/15pcs/14.11Kg/0.84CUFT
NOTE| 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Voltage adjustment can only be operated within the input range of 100~120VAC or 200-240VAC.
If the voltage adjustment is performed outside this range, it may cause abnormal output.
4. Tolerance : includes set up tolerance, line regulation and load regulation.
5. Line regulation is measured from low line to high line at rated load.
6. Load regulation is measured from 0% to 100% rated load.
7. Length of set up time is measured at cold start. Turning the power supply on/off frequently may lead to increase of the set up time.
8. Derating may be needed under low input voltages. Please refer to”Static Characteristics” sections for details.
9. Once protections are triggered, 3min(Typ.) of cold down time is required before restart.
10. The ambient temperature derating of 5°C/1000m is needed for operating altitude greater than 2000m(6500ft).
11. This power supply does not meet the harmonic current requirements outlined by EN61000-3-2. Please do not use this power supply
under the following conditions:
a) the end-devices is used within the European Union, and
b) the end-devices is connected to public mains supply with 220Vac or greater rated nominal voltage, and
c) the power supply is:
– installed in end-devices with average or continuous input power greater than 75W, or
– belong to part of a lighting system
Exception:
Power supplies used within the following end-devices do not need to fulfill EN61000-3-2
a) professional equipment with a total rated input power greater than 1000W;
b) symmetrically controlled heating elements with a rated power less than or equal to 200W
12. RCM is on voluntary basis and meets relevant IEC or AS/NZS standards complying with AS/NZS 4417.1.
13. Some model may not have the BIS logo, please contact your MEAN WELL sales for more information.

Block Diagram

Derating Curve

Static Characteristics

Mechanical Specification

Installation Manual

Please refer to : http://www.meanwell.com/manual.html