MW DDRH-60 Series 60W Ultra Wide Input DIN Rail Type DC-DC Converter Owner’s Manual

June 3, 2024
MW

DDRH-60 series
60W Ultra Wide Input DIN Rail Type DC-DC Converter

Features

  • 150.– 1500Vdc 10:1 ultra – wide input range
  • 57mm slim width
  • 4KVac I/O high isolation(Reinforced isolation)
  • Protections: Short circuit / Overload / Over voltage / Over temperature DC input under voltage / DC input reverse polarity
  • Cooling by free air convection
  • Can be installed on DIN rail TS-35/7.5 or 15
  • -30-‘+80°C ultra-wide operating temperature ( > +55°C derating)
  • Over voltage category II
  • Operating altitude up to 5000 meters
  • DC OK relay contact
  • DC output voltage adjustable(+20%)
  • 3 years warranty

MW DDRH 60 Series 60W Ultra Wide Input DIN Rail Type DC DC Converter -
Fig

 Applications

  • Photovoltaic power generation
  • High voltage freqency conversion
  • Industrial control system
  • Semiconductor fabrication equipment
  • Electro-mechanical apparatus
  • DC bus centralized application

Description

DDRH-60 series is a 150 r- 1500Vdc ultra-high input DIN rail type DC-DC converter which can supply stable working voltage for the load. It is suitable to be mounted on TS-35/7.5 or TS-35/15 rails. Main features are as following: easy to install DIN rail type, narrow width(57mm) in slim design, -30-+80°c wide range operating temperature, 4KVAC high isolation voltage, operation at 5000m altitude, high efficiency, low ripple & noise, complete protections and so on. DDRH-60 is compliant with BS EN/EN61000-6-2 standard regarding immunity for industrial environments. It is suitable for industrial automation, surveillance, telecommunication and can be widely deployed in the applications of new energy generation such as solar power, and windmill power generation, for instances, photovoltaic power systems, high voltage inverting , DC bus centralized application and so forth.

Model Encoding

SPECIFICATION

MODEL DDRH-60-5 DDRH-60-12 DDRH-60-24 DDRH-60-48
OUTPUT DC VOLTAGE 5V 12V 24V
RATED CURRENT 10A 5A 2.5A 1.25A
CURRENT RANGE 0 ~ 10A 0 ~ 5A 0 ~ 2.5A 0 ~ 1.25A
RATED POWER 50W 60W 60W 60W
RIPPLE & NOISE (max.) Note.2 100mVp-p 120mVp-p 150mVp-p 200mVp-p
VOLTAGE ADJ. RANGE 5 ~ 6V 12 ~ 15V 24 ~ 29V 48 ~ 54V
VOLTAGE TOLERANCE Note.3 ±1.5% ±1.5% ±1.0% ±1.0%
LINE REGULATION ±0.5% ±0.5% ±0.5% ±0.5%
LOAD REGULATION ±1.5% ±0.5% ±0.5% ±0.5%
EXTERNAL CAPACITANCE LOAD (Max.) 6000μF 4000μF 2500μF 1000μF
INPUT VOLTAGE RANGE Note.4 150 ~ 1500Vdc
EFFICIENCY (Typ.) 200Vdc 80% 83% 86%
800Vdc 81% 85% 87% 88%
1500Vdc 76% 81% 84% 83%
INRUSH CURRENT (max.) COLD START   120A /1500Vdc      80A/800Vdc

30A/150Vdc
PROTECTION| OVERLOAD| 105 ~ 135% rated output power
Protection type : Hiccup up mode when output voltage<55%, recovers automatically after condition is removed; Constant current limiting, recovers automatically after fault condition is removed within 55% ~ 100% rated output voltage
OVER VOLTAGE| 6.6 ~ 8.4V| 16.5 ~ 21V| 30 ~ 38V| 55 ~ 60V
Protection type : Hiccup up mode, recovers automatically after fault condition is removed
OVER TEMPERATURE| Protection type : Hiccup up mode, recovers automatically after fault condition is removed


DC INPUT

| REVERSE POLARITY| By internal Bridge Diode, no damage, recovers automatically after fault condition removed
UNDER VOLTAGE LOCKOUT| Under voltage protection range:120 ~ 130Vdc , Under voltage release range:130 ~ 146.5Vdc
FUNCTION| DC OK SIGNAL| Relay contact rating(max.) : 30V / 1A resistive
ENVIRONMENT| WORKING TEMP.| -30 ~ +80℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +80℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 55℃)
VIBRATION| Component: 10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting clip: Compliance to IEC60068-2-6
OPERATING ALTITUDE Note.5| 5000 meters /OVCⅡ
OVER VOLTAGE CATEGORY| Ⅱ; According to EN62109-1; altitude up to 5000 meters
SAFETY & **EMC**

(Note.7)

| SAFETY STANDARDS| IEC62109-1(LVD) , EAC TP TC 004 approved; Design refer to UL1741(By request)
WITHSTAND VOLTAGE| I/P-O/P:4KVAC      O/P-DC OK:0.5KVAC
ISOLATION RESISTANCE| I/P-O/P, 100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION| Parameter| Standard| Test Level / Note
Conducted| BS EN/EN55032(CISPR32)| Class A
Radiated| BS EN/EN55032(CISPR32)| Class A
Voltage Flicker| BS EN/EN61000-3-3| ——-
EMC IMMUNITY| BS EN/EN55035, BS EN/EN61000-6-2
Parameter| Standard| Test Level /Note
ESD| BS EN/EN61000-4-2| Level 3, 8KV air; Level 2, 4KV contact, criteria A
Radiated Susceptibility| BS EN/EN61000-4-3| Level 3, 10V, criteria A
EFT/Burest| BS EN/EN61000-4-4| Level 3, 2KV, criteria A
Surge| BS EN/EN61000-4-5| Level 4, 2KV/Vin+ ~ Vin-, criteria A
Conducted| BS EN/EN61000-4-6| Level 3, 10V, criteria A
Magnetic Field| BS EN/EN61000-4-8| Level 4, 30A, criteria A
Voltage Dips and interruptions| BS EN/EN61000-4-11| >95% dip 0.5 periods, 30% dip 25 periods, >95% interruptions 250 periods


OTHERS

| MTBF| 454.5K hrs min.      MIL-HDBK-217F (25℃);           503K hrs min.   Telcordia TR/SR-332 (Bellcore) (25℃)
DIMENSION| 5793.5105mm (WHD)
PACKING| 0.8Kg; 16pcs/12.8Kg/0.84CUFT
NOTE| 1.  All parameters NOT specially mentioned are measured at 600Vdc input, rated load and 25℃ of ambient temperature.
2.  Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1μf & 47μf parallel capacitor.
|3.  Tolerance : includes set up tolerance, line regulation and load regulation.
4.  Derating may be needed under low input voltage. Please check the derating curve for more details.
5.  The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
6.  Installation clearances : 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded permanently with full power. In case the adjacent device is a heat source, 15mm clearance is recommended.
7.  The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Block Diagram

MW DDRH 60 Series 60W Ultra Wide Input DIN Rail Type DC DC Converter - Block
Diagram

Derating Curve

MW DDRH 60 Series 60W Ultra Wide Input DIN Rail Type DC DC Converter - Block
Diagram11 AMBIENT TEMPERATURE (℃ )

Static Characteristics

MW DDRH 60 Series 60W Ultra Wide Input DIN Rail Type DC DC Converter -
Static Characteristics

DC OK Relay Contact

Contact Close PSU turns ON / DC OK.
Contact Open PSU turns OFF / DC Fail.
Contact Ratings (max.) 30V/1A resistive load.

Mechanical Specification

MW DDRH 60 Series 60W Ultra Wide Input DIN Rail Type DC DC Converter -
Mechanical Specification

External FUSE wiring instruction

External FUSE is required.FUSE specification: 4A/1500Vdc.
Suggested model:

Fuse Brand Manufacturer Part NO. MW’s Order NO.
Fuse Fuse Holder Fuse + Fuse Holder
WalterFuse WJ30-4 WJ30-H
Littelfuse SPXV-4A LFPXV/LPXV
Bussmann PV-4A10F85L CHPV15L85

MW DDRH 60 Series 60W Ultra Wide Input DIN Rail Type DC DC Converter -
FUSE

Installation Instruction

MW DDRH 60 Series 60W Ultra Wide Input DIN Rail Type DC DC Converter -
Static Characteristics1

Installation Manual

Please refer to : http://www.meanwell.com/manual.html

https://www.meanwell.com/Upload/PDF/DDRH.pdf Downloaded from Arrow.com.