MW MEAN WELL 200W PWM Output Driver User Manual

June 7, 2024
MW MEAN WELL

MW MEAN WELL 200W PWM Output Driver User Manual
MW MEAN WELL 200W PWM Output Driver

Icons

Features

  • Constant Voltage PWM style output with user changeable frequency up to 4KHz compliant lEEE1789-2015 and EU Ecodesign SVM requirement
  • Min.dimming level 0.01%
  • Plastic housing with class ll design
  • Standby power consumption<0.5W
  • Support KNX Data Secure
  • No need KNX-DALl gateway
  • Typical lifetime>50000 hours
  • 5 years warranty

Applications

  • LED strip lighting
  • lndoor LED lighting
  • LED decorative lighting
  • LED architecture lighting
  • Type “HL” for use in class l, division 2 hazardous (classified)
  • Cove lighting

Description

PWM-200KN series is a 200W AC/DC LED driver featuring the constant voltage mode with PWM style output, which is able to maintain the colour temperature and the brightness homogeneity when driving all kinds of LED strips and constant voltage LED bulbs.The built-in KNX interface is to avoid using the complicated KNX-DALl gateway and equipped with KNX Data Secure. KNX Data Secure offers protection against manipulation in building auto mation and can be configured in the ETS project.
PWM-200KN operates from 100~305VAC and offers models with output voltage between 12V & 48V. Thanks to the high efficiency up to 94%, with the fanless design, the entire series is able to operate for -40°C ~ +85°C case temperature under free air convection.
The minimal dimming level low to 0.01% is suitable for low light level applications e.g. cinema. The output frequency is changeable up  to 4KHz complaint lEEE1789-2015 no risk requirement and EU Ecodesign stroboscopic visibility measure(SVM) concern due to light fickering. requirement providing a great solution for health concern due to light fickering.

Model Encoding

Model Encoding

Type

| Function| Note
---|---|---
KN| KNX control technology|

ln stock

SPECIFICATIONS

MODEL

| PWM-200-12| PWM-200-24| PWM-200-36|

PWM-200-48

---|---|---|---|---
OUTPUT| DC VOLTAGE|

12V

| 24V| 36V|

48V

RATED CURRENT|

15A

|

8.3A

| 5.55A|

4.17A

RATED POWER|

180W

|

199.2W

| 199.8W|

200.1W

DIMMING RANGE| 0 ~ 100%
PWM FREQUENCY (Typ.)| 200~4000Hz user changable via ETS
SETUP, RISE TIME Note.2| 500ms, 80ms/230VAC, 1200ms, 80ms/115VAC
HOLD UP TIME (Typ.)| 10ms/230VAC or 115VAC
INPUT| **VOLTAGE RANGE Note. 3| 100 ~ 305VAC         142 ~ 431VDC
(Please refer to “STATIC CHARACTERISTIC” section)
FREQUENCY RANGE| 47 ~ 63Hz
POWER FACTOR (Typ.)| PF>0.97/115VAC, PF>0.96/230VAC, PF>0.94/277VAC @ full load
(Please refer to “POWER FACTOR (PF) CHARACTERISTIC” section)
****
TOTAL HARMONIC DISTORTION| THD<20%(@load≧60%/115VAC,  230VAC; @load≧75%/277VAC)
(Please refer to “TOTAL HARMONIC DISTORTION” section)
EFFICIENCY (Typ.)**|

92%

| 93%| 94%|

94%

AC CURRENT (Typ.)| 2.2A / 115VAC         1.1A / 230VAC         0.9A / 277VAC
INRUSH CURRENT (Typ.)| COLD START 65A(twidth=550μs measured at 50% Ipeak) at 230VAC ; Per NEMA 410
MAX. NO. of PSUs on 16A CIRCUIT BREAKER| 3 units (circuit breaker of type B) / 5 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT| <0.75mA / 277VAC
STANDBY POWER CONSUMPTION| standby power consumption<0.5W when dimming off
PROTECTION| OVERLOAD| 108 ~ 135% rated output power
Hiccup mode or Constant current limiting, recovers automatically after fault condition is removed
SHORT CIRCUIT| Shut down o/p voltage, re-power on to recover
OVER VOLTAGE| 13 ~ 18V| 27 ~ 34V| 41 ~ 49V| 53 ~ 65V
Shut down o/p voltage, re-power on to recover after fault condition is removed
OVER TEMPERATURE| Shut down o/p voltage, re-power on to recover after fault condition is removed
ENVIRONMENT| WORKING TEMP.| Tcase=-40 ~ +85℃ (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)
MAX. CASE TEMP.| Tcase=+85℃
WORKING HUMIDITY| 20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +80℃, 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY & **EMC| SAFETY STANDARDS Note.5| UL8750( type ”HL” ), CSA C22.2 No. 250.13-12; ENEC BS EN/EN61347-1, BS EN/EN61347-2-13,BS EN/EN62384 independent, EAC TP TC 004,GB19510.1,GB19510.14 approved; Design refer to BS EN/EN60335-1, According to BS EN/EN61347-2-13 appendix J suitable for emergency installations.
KNX STANDARDS| Certified protocol
WITHSTAND VOLTAGE| I/P-O/P: 3.75KVAC
ISOLATION RESISTANCE| I/P-O/P: 100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION Note.6| Compliance to BS EN/EN55015, BS EN/EN61000-3-2 Class C (@load≧60%) ; BS EN/EN61000-3-3,GB17743 and GB17625.1,EAC TP TC 020
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN61547, light industry level (surge immunity, Line-Line 2KV),EAC TP TC 020
OTHERS| MTBF| 553.6 K hrs min.      Telcordia SR-332 (Bellcore) ; 170 K hrs min.       MIL-HDBK-217F (25℃)
DIMENSION| 1956839.5mm (LWH)
PACKING| 1.03Kg; 12pcs/13.4Kg/0.71CUFT
NOTE**|

  1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25℃ of ambient temperature.
  2. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.
  3. De-rating may be needed under low input voltages. Please refer to “STATlC CHARACTERlSTlC” sections for details.
  4. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
  5. This series meets the typical life expectancy of >50,000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about 75℃or less.
  6.  Please refer to the warranty statement on MEAN WELL’s website at http://www.meanwell.com
  7.  The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitudes higher than 2000m(6500ft).
  8. For any application note and lP waterproof function installation caution, please refer our user manual before using. LED_EN [PDF]
  9. lt is not recommended to connect to capacitive loads

DIMMING OPERATION

Dimming Operation

Dimming principle for PWM style output

  • Dimming is achieved by varying the duty cycle of the output current.

Dimming Operation

KNXInterface

Parametrization   options

|

Description

---|---
Switch functions|

  • Turn on brightness
  • Dimming speed for turn on/off
  • Switch telegram and status
  • Switch on/off delay

Dimming|

  • Dimming speed for 0~100%
  • Allow switch on via relative dimming

Brightness value|

  • Dimming speed for transition brightness values
  • Permit set switch on and off brightness via value
  • Brightness value and status

More parameters can be found in the ETS application database and instruction manual
The device is equipped with KNX Data Secure. KNX Data Secure offers protection against manipulation in building automation and can be configured in the ETS project. Detailed specialist knowledge is required. A device certificate, which is attached to the device, is required for the first configuration. After configuration and ready for runtime (daily) operation, it is recommended to remove the certificate from the device and to store it securely. For details, please refer to the instruction manual.

MEAN WELL

Device Certificate
qr code

OUTPUT LOAD TEMPERATURE

Output Load ve Temperature
AMBIENT TEMPERATURE,Ta (ºC)

Output Load ve Temperature
Tcase (ºC)

STATIC CHARACTERISTIC

Static Characteristics Graph
INPUT VOLTAGE (V) 60Hz

POWER FACTOR PF CHARACTERISTIC

Power Factor Characteristic Graph
LOAD

TOTAL HARMONIC DISTORTION (THD)

48V Model, Tcase at 75℃

Total Harmonic Distortion Graph
Load

EFFICIENCY LOAD

PWM KN -200 series possess superior working efficiency that up to 94% can
be reached in field applications.
※ 48V Model, Tcase at 75℃

Efficiency Graph
Load

LIFE TIME

Life Time Graph

Block Diagram

Block Diagram

Mechanical Specification

Mechanical Specification

Recommend Mounting Direction

Mounting Direction

Installation Manual

Connection for KN-type

Connection for KN-type

Cautions
  • Before commencing any installation or maintenance work, please disconnect the power supply from the Ensure that it cannot be re-connected inadvertently!

  • Keep proper ventilation around the unit and do not stack any object on Also a 10-15 cm clearance must be kept when the adjacent device is a heat source.

  • Mounting orientations other than standard orientation or operate under high ambient temperature may increase the internal component temperature and will require a de-rating in output

  • Current rating of an approved primary /secondary cable should be greater than or equal to that of the Please refer to its specification.

  • For LED drivers with waterproof connectors, verify that the linkage between the unit and the lighting fixture is tight so that water cannot intrude into the

  • Tc is identified on the product label. Please make sure that temperature of Tc point will not exceed limit.

  • DO NOT connect “KNX- to -V”.

  • The power supply is considered as a component that will be operated in combination with final Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.

  • For more information about installation, Please refer to: http://www.meanwell.com/manual.html for details.