IVO4S NCH 4 Square Downlight
“`html
Specifications
-
Product Name: IVO Shallow Recess Downlight
-
Model: IVO4S NCH, IVO4S CP/ICAT, IVO6S NCH, IVO6S CP/ICAT
-
Options: Flangeless, Emergency Lighting, Controls
(DMX/NLIGHT/NLIGHTER/NLTAIR2/NLTAIREM2) -
Trim Options: Parabolic Trim, Lensed Wallwash Trim
-
Revision: A
-
Date: 01/24
Product Usage Instructions
Safety
Before installation or maintenance, ensure the power is switched
off to prevent electric shock.
Identification
Refer to the product model number and options to identify the
specific downlight and trim type.
Housing Frame Installation
Follow the provided installation instructions to securely mount
the housing frame in the ceiling.
Wiring Diagrams
Consult the wiring diagrams to correctly connect the downlight
to the power source.
Flangeless (Optional)
If using the flangeless option, ensure proper alignment and
installation for a seamless look.
Trim/LED Module
Install the selected trim or LED module according to the
manufacturer’s instructions for desired lighting effects.
Inspection/Field Service
Regularly inspect the downlight for any damage or malfunction.
Seek professional service if needed.
FAQ
Q: Can I install the downlight without a housing frame?
A: No, it is important to install the housing frame as per the
instructions for safe and proper operation.
Q: Can I use controls with all models of the downlight?
A: Controls can be used with specific models mentioned in the
product identification section. Refer to the options available for
each model.
Q: How do I change the trim of the downlight?
A: Follow the provided guidelines to safely remove and replace
the trim of the downlight for different lighting effects.
“`
IVO Shallow Recess Downlight
INSTALLATION INSTRUCTIONS IVO4S/IVO6S
Safety
Identification
Housing Frame Installation
Wiring Diagrams
Flangeless (Optional)
Trim/LED Module
Inspection/Field Service
gothamlighting.com | 800-705-SERV (7378) | techsupport- downligh@acuitybrands.com |©2020 AcuityBrands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.
912-00481-001 REV. A 01/24
1
IVO Shallow Recess Downlight
INSTALLATION INSTRUCTIONS IVO4S/IVO6S
Safety
Identification
Housing Frame Installation
Wiring Diagrams
Flangeless (Optional)
Trim/LED Module
Inspection/Field Service
gothamlighting.com | 800-705-SERV (7378) | techsupport- downligh@acuitybrands.com |©2020 AcuityBrands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.
912-00481-001 REV. A 01/24
2
IVO Shallow Recess Downlight
INSTALLATION INSTRUCTIONS IVO4S/IVO6S
Safety
Identification
Housing Frame Installation
Wiring Diagrams
Flangeless (Optional)
Trim/LED Module
Inspection/Field Service
gothamlighting.com | 800-705-SERV (7378) | techsupport- downligh@acuitybrands.com |©2020 AcuityBrands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.
912-00481-001 REV. A 01/24
3
IVO Shallow Recess Downlight
INSTALLATION INSTRUCTIONS IVO4S/IVO6S
Safety
Identification
Housing Frame Installation
Wiring Diagrams
Flangeless (Optional)
Trim/LED Module
Inspection/Field Service
gothamlighting.com | 800-705-SERV (7378) | techsupport- downligh@acuitybrands.com |©2020 AcuityBrands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.
912-00481-001 REV. A 01/24
4
IVO Shallow Recess Downlight
INSTALLATION INSTRUCTIONS IVO4S/IVO6S
Safety
Identification
Housing Frame Installation
Wiring Diagrams
Flangeless (Optional)
Trim/LED Module
Inspection/Field Service
gothamlighting.com | 800-705-SERV (7378) | techsupport- downligh@acuitybrands.com |©2020 AcuityBrands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.
912-00481-001 REV. A 01/24
5
IVO Shallow Recess Downlight
INSTALLATION INSTRUCTIONS IVO4S/IVO6S
Safety
Identification
Housing Frame Installation
Wiring Diagrams
Flangeless (Optional)
Trim/LED Module
Inspection/Field Service
A. Identification – IVO Shallow Recess Downlights
IVO4S NCH
IVO4S CP/ICAT IVO4S NCH Emergency E6WR
IVO4S NCH with Controls (DMX/NLIGHT/NLIGHTER/NLTAIR2/NLTAIREM2)
IVO4S NCH Emergency E10WCPR/15WCPR/GTD (access above ceiling required)
NOTE: Illustrations are used for reference only and can differ slightly from the actual luminaires installed. However, key components addressed in this information are represented as accurately as possible.
gothamlighting.com | 800-705-SERV (7378) | techsupport- downligh@acuitybrands.com |©2020 AcuityBrands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.
912-00481-001 REV. A 01/24
6
IVO Shallow Recess Downlight
INSTALLATION INSTRUCTIONS IVO4S/IVO6S
Safety
Identification
Housing Frame Installation
Wiring Diagrams
Flangeless (Optional)
Trim/LED Module
Inspection/Field Service
A. Identification – IVO Shallow Recess Downlights
IVO6S NCH
IVO6S NCH Emergency E10WCPR/15WCPR/GTD (access above ceiling required)
IVO6S NCH with Controls (DMX/NLIGHT/NLIGHTER/NLTAIR2/NLTAIREM2)
Change to open frame
IVO6S CP/ICAT IVO6S NCH Emergency E6WR
NOTE: Illustrations are used for reference only and can differ slightly from the actual luminaires installed. However, key components addressed in this information are represented as accurately as possible.
gothamlighting.com | 800-705-SERV (7378) | techsupport- downligh@acuitybrands.com |©2020 AcuityBrands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.
912-00481-001 REV. A 01/24
7
IVO Shallow Recess Downlight
INSTALLATION INSTRUCTIONS IVO4S/IVO6S
Safety
Identification
Housing Frame Installation
Wiring Diagrams
Flangeless (Optional)
Trim/LED Module
Inspection/Field Service
A. Identification – IVO Shallow Recess Trims
IVO4S P (Parabolic Trim)
IVO4SQS P (Parabolic Trim)
IVO4S LW (Lensed Wallwash Trim)
IVO4SQS LW (Lensed Wallwash Trim)
NOTE: Illustrations are used for reference only and can differ slightly from the actual luminaires installed. However, key components addressed in this information are represented as accurately as possible.
gothamlighting.com | 800-705-SERV (7378) | techsupport- downligh@acuitybrands.com |©2020 AcuityBrands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.
912-00481-001 REV. A 01/24
8
IVO Shallow Recess Downlight
INSTALLATION INSTRUCTIONS IVO4S/IVO6S
Safety
Identification
Housing Frame Installation
Wiring Diagrams
Flangeless (Optional)
Trim/LED Module
Inspection/Field Service
A. Identification – IVO Shallow Recess Trims
IVO6S P (Parabolic Trim)
IVO6SQS P (Parabolic Trim)
IVO6S LW (Lensed Wallwash Trim)
IVO6SQS LW (Lensed Wallwash Trim)
NOTE: Illustrations are used for reference only and can differ slightly from the actual luminaires installed. However, key components addressed in this information are represented as accurately as possible.
gothamlighting.com | 800-705-SERV (7378) | techsupport- downligh@acuitybrands.com |©2020 AcuityBrands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.
912-00481-001 REV. A 01/24
9
IVO Shallow Recess Downlight
INSTALLATION INSTRUCTIONS IVO4S/IVO6S
Safety
Identification
Housing Frame Installation
Wiring Diagrams
Flangeless (Optional)
A. Identification Flangeless Trim Adapter
Trim/LED Module
Inspection/Field Service
IVO4ADPT FL (Flangeless Trim Adapter)
IVO4SQADPT FL (Flangeless Trim Adapter)
IVO6ADPT FL (Flangeless Trim Adapter)
IVO6SQADPT (Flangeless Trim Adapter)
NOTE: Illustrations are used for reference only and can differ slightly from the actual luminaires installed. However, key components addressed in this information are represented as accurately as possible.
gothamlighting.com | 800-705-SERV (7378) | techsupport- downligh@acuitybrands.com |©2020 AcuityBrands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.
912-00481-001 REV. A
10
01/24
IVO Shallow Recess Downlight
INSTALLATION INSTRUCTIONS IVO4S/IVO6S
Safety
Identification
Housing Frame Installation
Wiring Diagrams
Flangeless (Optional)
Trim/LED Module
Inspection/Field Service
B. NCH Housing Installation – IVO Shallow Recess Downlights
1
For best results, cut ceiling opening as specified: 4″ Flanged ceiling opening (round): 5″ dia. (12.7 cm)
4″ Flanged ceiling opening (square): 5″ across flats (12.7 cm)
6″ Flanged ceiling opening (round): 7-1/8″ dia. (18.1 cm)
6″ Flanged ceiling opening (square): 7-1/8″ across flats (18.1 cm)
Ceiling thickness range is from 5/8″ to 2″.
NOTE: For flangeless installation, cut ceiling opening as specified: 4″
Flangeless ceiling opening (round): 5-1/4″ dia. (13.3 cm) 4″ Flangeless
ceiling opening (square): 5-1/4″ across flats (13.3 cm) 6″ Flangeless ceiling
opening (round): 7-3/8″ dia. (18.7 cm) 6″ Flangeless ceiling opening (square):
7-3/8″ across flats (18.7 cm)
Please refer to flangeless adapter instructions prior to housing
installation (pages 18-20).
Fixture should be used in ceilings with 25°C ambient temperature as standard.
Non-IC rated luminaires should be installed with 1/2″ clearance on all sides from non-combustible materials and with 3″ clearance on all sides from insulation (unless marked spacing noted otherwise). If fixtures are ICAT and labeled as inherently protected, insulation may be applied directly onto fixture enclosure.
Insert the supplied mounting bars or chosen mounting
2 bar style into “Universal Mounting Brackets” on each side of the fixture
(Fig 1). (See below for acceptable mounting bar styles.)
Fig. 1
Universal Mounting Bracket: Universal mounting bracket also accepts various
mounting bars (supplied separately).
¾” C
1-1/2″ C
CHANNEL
CHANNEL
NOTE: Illustrations are used for reference only and can differ slightly from the actual luminaires installed.
However, key components addressed in this information are represented as accurately as possible.
½” OR ¾” ½” CONDUIT ½” ANGLE
FLAT STRAP
BAR
gothamlighting.com | 800-705-SERV (7378) | techsupport- downligh@acuitybrands.com |©2020 AcuityBrands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.
912-00481-001 REV. A
11
01/24
IVO Shallow Recess Downlight
INSTALLATION INSTRUCTIONS IVO4S/IVO6S
Safety
Identification
Housing Frame Installation
Wiring Diagrams
Flangeless (Optional)
Trim/LED Module
Inspection/Field Service
B. NCH Housing Installation – IVO Shallow Recess Downlights
3
Install mounting frame to ceiling, securing bars to t-bar or joists per local code. To lock mounting bars horizontally,
use channel locks to compress the locking tabs as shown in
Fig. 2
4 If necessary, adjust the mounting frame vertically to align the bottom edge of the aperture flush or slightly above the ceiling plane (Fig. 3). Vertical slot allows for 1-1/8″ of adjustment. Retighten wing nut when finished.
Fig. 2
Fig. 3
LOCKING TABS
NOTE: Illustrations are used for reference only and can differ slightly from the actual luminaires installed. However, key components addressed in this information are represented as accurately as possible.
gothamlighting.com | 800-705-SERV (7378) | techsupport- downligh@acuitybrands.com |©2020 AcuityBrands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.
912-00481-001 REV. A
12
01/24
IVO Shallow Recess Downlight
INSTALLATION INSTRUCTIONS IVO4S/IVO6S
Safety
Identification
Housing Frame Installation
Wiring Diagrams
Flangeless (Optional)
Trim/LED Module
Inspection/Field Service
B. NCH Housing Installation – IVO Shallow Recess Downlights
5
Remove a knockout on rear of junction box to feed supply power to fixture (Fig. 4). Push-in conduit fittings
are strongly recommended. Supply wire must meet
applicable electrical codes and be rated for a minimum
of 90°C. Junction box is thru-wire rated for 8 – No. 12
AWG conductors (4in-4out). Appropriate control wires to
be provided by installer in accordance with selected
driver option.
6
Open junction box access door by rotating door latch to the right and swing door out of the way (Fig. 5).
Fig. 4
Dual Knock-outs provided for 1/2″ and 3/4″ conduit fittings
Fig. 5
NOTE: Illustrations are used for reference only and can differ slightly from the actual luminaires installed. However, key components addressed in this information are represented as accurately as possible.
gothamlighting.com | 800-705-SERV (7378) | techsupport- downligh@acuitybrands.com |©2020 AcuityBrands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.
912-00481-001 REV. A
13
01/24
IVO Shallow Recess Downlight
INSTALLATION INSTRUCTIONS IVO4S/IVO6S
Safety
Identification
Housing Frame Installation
Wiring Diagrams
Flangeless (Optional)
Trim/LED Module
Inspection/Field Service
B. NCH Housing Installation – IVO Shallow Recess Downlights
Pull supply wires and driver leads through aperture if
7 there is not sufficient plenum space to work. Gotham recommends supply leads
be at least 7″ long to reach through aperture opening (Fig. 6). Complete
necessary splices according to wiring diagram for selected fixture options
(See Pages 15-17). (0-10V Option Shown)
8
Push all wires back inside splice box ensuring no wires remain outside junction box opening. Swing
junction box access door closed and secure with
latch. (Fig. 7)
Fig. 6
Fig. 7
gothamlighting.com | 800-705-SERV (7378) | techsupport- downligh@acuitybrands.com |©2020 AcuityBrands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.
912-00481-001 REV. A
14
01/24
IVO Shallow Recess Downlight
INSTALLATION INSTRUCTIONS IVO4S/IVO6S
Safety
Identification
Housing Frame Installation
Wiring Diagrams
Flangeless (Optional)
Trim/LED Module
Inspection/Field Service
C. Wiring Diagrams – IVO Shallow Recess Downlights
EZ/ZT (0-10V Dimming)
ELV (Phase Dimming) DALI
gothamlighting.com | 800-705-SERV (7378) | techsupport- downligh@acuitybrands.com |©2020 AcuityBrands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.
912-00481-001 REV. A
15
01/24
IVO Shallow Recess Downlight
INSTALLATION INSTRUCTIONS IVO4S/IVO6S
Safety
Identification
Housing Frame Installation
Wiring Diagrams
Flangeless (Optional)
Trim/LED Module
Inspection/Field Service
C. Wiring Diagrams – IVO Shallow Recess Downlights
DMX
E6WR
E10WCPR/E15WCPR
gothamlighting.com | 800-705-SERV (7378) | techsupport- downligh@acuitybrands.com |©2020 AcuityBrands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.
912-00481-001 REV. A
16
01/24
IVO Shallow Recess Downlight
INSTALLATION INSTRUCTIONS IVO4S/IVO6S
Safety
Identification
Housing Frame Installation
Wiring Diagrams
Flangeless (Optional)
Trim/LED Module
Inspection/Field Service
C. Wiring Diagrams – IVO Shallow Recess Downlights
NLIGHT
NLTAIR2 NLIGHTER
NLTAIREM2
gothamlighting.com | 800-705-SERV (7378) | techsupport- downligh@acuitybrands.com |©2020 AcuityBrands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.
912-00481-001 REV. A
17
01/24
IVO Shallow Recess Downlight
INSTALLATION INSTRUCTIONS IVO4S/IVO6S
Safety
Identification
Housing Frame Installation
Wiring Diagrams
Flangeless (Optional)
Trim/LED Module
Inspection/Field Service
D. Flangeless Trim Adapter Installation (Optional) – IVO Shallow Recess
Downlights
If flangeless trims are specified, a Gotham flangeless adapter must be used.
For self flanged applications, skip to Trim/LED module installation
instructions (pages 2123).
Gotham flangeless adapters are intended to be used only with Gotham new
construction and remodel housings and corresponding trims.
For best results, use Gotham flangeless adapters with new, unpainted, paper-
faced gypsum board only. Use of these adapters with other ceiling materials is
not recommended.
Note: For best appearance, at minimum a Level 4 drywall finish for textured
ceilings and a Level 5 drywall finish for flat ceilings is recommended. In
addition, use of a setting-type joint compound such as Sheetrock® brand
Durabond® is recommended to increase durability and prevent the formation of
hairline cracks over time.
Install housing based on mounting frame installation instructions
1 For flange-less installation, cut ceiling opening as specified: 4″ Round &
Square Flangeless Ceiling opening (NCH & RM): 5-1/4″ (13.3 cm) 6″ Round &
Square Flangeless Ceiling opening (NCH & RM): 7-3/8″ (18.7 cm)
2 Adhere flangeless adapter to ceiling using joint compound, such as
Sheetrock® brand Durabond®, or adhesive.
NOTE: Illustrations are used for reference only and can differ slightly from the actual luminaires installed. However, key components addressed in this information are represented as accurately as possible.
gothamlighting.com | 800-705-SERV (7378) | techsupport- downligh@acuitybrands.com |©2020 AcuityBrands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.
912-00481-001 REV. A
18
01/24
IVO Shallow Recess Downlight
INSTALLATION INSTRUCTIONS IVO4S/IVO6S
Safety
Identification
Housing Frame Installation
Wiring Diagrams
Flangeless (Optional)
Trim/LED Module
Inspection/Field Service
D. Flangeless Trim Adapter Installation (Optional) – IVO Shallow Recess Downlights
Remove any excess compound or adhesive, before allowing to
3 dry, from the front of the flangeless adapter.
4 Apply joint compound to flangeless trim adapter up to the edge of the paint shield. Smooth and feather out. Repeat until all edges surrounding paint shield are filled. Remove any excess compound before allowing to dry.
NOTE: Illustrations are used for reference only and can differ slightly from the actual luminaires installed. However, key components addressed in this information are represented as accurately as possible.
gothamlighting.com | 800-705-SERV (7378) | techsupport- downligh@acuitybrands.com |©2020 AcuityBrands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.
912-00481-001 REV. A
19
01/24
IVO Shallow Recess Downlight
INSTALLATION INSTRUCTIONS IVO4S/IVO6S
Safety
Identification
Housing Frame Installation
Wiring Diagrams
Flangeless (Optional)
Trim/LED Module
Inspection/Field Service
D. Flangeless Trim Adapter Installation (Optional) – IVO Shallow Recess Downlights
5 Sand until the joint compound is feathered to an even transition between the flangeless adapter and drywall.
6 After painting is completed, remove any excess paint or joint compound from the inside surfaces where the trim flange will rest. Install trim.
Trim Installed
NOTE: Illustrations are used for reference only and can differ slightly from the actual luminaires installed. However, key components addressed in this information are represented as accurately as possible.
gothamlighting.com | 800-705-SERV (7378) | techsupport- downligh@acuitybrands.com |©2020 AcuityBrands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.
912-00481-001 REV. A
20
01/24
IVO Shallow Recess Downlight
INSTALLATION INSTRUCTIONS IVO4S/IVO6S
Safety
Identification
Housing Frame Installation
Wiring Diagrams
Flangeless (Optional)
Trim/LED Module
Inspection/Field Service
E. Trim/LED Module Installation – IVO Shallow Recess Downlights
If LED module was disconnected from mounting
1 frame in previous step, open quick disconnect
enclosure door through aperture (Fig. 1).
Quick disconnect enclosure door
Connect the LED module input wire connector to
2 the driver output connector inside the quick
disconnect enclosure. Place the conduit into quick
disconnect enclosure recess and snap door closed
to properly strain relief connection (Fig. 2).
Fig. 1
Fig. 2
Fig. 7
NOTE: Illustrations are used for reference only and can differ slightly from the actual luminaires installed. However, key components addressed in this information are represented as accurately as possible.
gothamlighting.com | 800-705-SERV (7378) | techsupport- downligh@acuitybrands.com |©2020 AcuityBrands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.
912-00481-001 REV. A
21
01/24
IVO Shallow Recess Downlight
INSTALLATION INSTRUCTIONS IVO4S/IVO6S
Safety
Identification
Housing Frame Installation
Wiring Diagrams
Flangeless (Optional)
Trim/LED Module
Inspection/Field Service
E. Trim/LED Module Installation – IVO Shallow Recess Downlights
3
With the LED module hanging through the aperture, hold LED module in one hand. With other hand, align the
notches in trim with the twist lock component (highlighted
in blue) inside the LED Module (Fig 3). Ensure the trim is
fully seated. Rotate the trim clockwise until locked into
place (Fig 4).
Fig. 3
Fig. 4
NOTE: Illustrations are used for reference only and can differ slightly from the actual luminaires installed. However, key components addressed in this information are represented as accurately as possible.
gothamlighting.com | 800-705-SERV (7378) | techsupport- downligh@acuitybrands.com |©2020 AcuityBrands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.
912-00481-001 REV. A
22
01/24
IVO Shallow Recess Downlight
INSTALLATION INSTRUCTIONS IVO4S/IVO6S
Safety
Identification
Housing Frame Installation
Wiring Diagrams
Flangeless (Optional)
Trim/LED Module
Inspection/Field Service
E. Trim/LED Module Installation – IVO Shallow Recess Downlights
*Protected by U.S. Patent No. 10,724,717 B2
4
Open retention springs* on LED module and hold upright in vertical position while inserting LED module through aperture and allowing springs to pull trim tight to
ceiling. For wall wash style trims, rotate LED module so that light is directed at wall to
be illuminated.
Flexible conduit not shown
NOTE: Illustrations are used for reference only and can differ slightly from the actual luminaires installed. However, key components addressed in this information are represented as accurately as possible.
gothamlighting.com | 800-705-SERV (7378) | techsupport- downligh@acuitybrands.com |©2020 AcuityBrands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.
912-00481-001 REV. A
23
01/24
IVO Shallow Recess Downlight
INSTALLATION INSTRUCTIONS IVO4S/IVO6S
Safety
Identification
Housing Frame Installation
Wiring Diagrams
Flangeless (Optional)
Trim/LED Module
Inspection/Field Service
F. Inspection/Field Service – IVO Shallow Recess Downlights
CAUTION! Use care when removing the LED module for
!
maintenance purposes. Support the spring assemblies during removal to prevent injury.
1
To access driver, optic, or LED light engine, remove LED module by gripping trim around flange edge and
begin to pull downward. Retention spring housings will
catch on interior edge of aperture and stop. When
springs stop on aperture edge, use fingers to support
spring housings in upright position while continuing to
pull LED module out of aperture. (Fig. 1)
Fig. 1 (flexible conduit not shown)
NOTE: Illustrations are used for reference only and can differ slightly from the actual luminaires installed. However, key components addressed in this information are represented as accurately as possible.
gothamlighting.com | 800-705-SERV (7378) | techsupport- downligh@acuitybrands.com |©2020 AcuityBrands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.
912-00481-001 REV. A
24
01/24
IVO Shallow Recess Downlight
INSTALLATION INSTRUCTIONS IVOS/IVOSQS REPLACEMENT PARTS
Safety
Identification
Housing Frame Installation
Wiring Diagrams
Flangeless (Optional)
Trim/LED Module
Inspection/Field Service
F. Inspection/Field Service LED Module Replacement
2
Open quick disconnect enclosure door through aperture.
Connector latch
3
Remove conduit from strain relief recess of quick disconnect enclosure. Depress connector latch to
disconnect while supporting LED module to prevent from
falling. Connect new LED module input wire connector to
the driver output connector inside the quick disconnect
enclosure. Place the conduit into quick disconnect
enclosure recess and snap door closed to properly strain
relief connection. Re-install LED module into fixture.
Quick disconnect enclosure door
Conduit strain relief recess
NOTE: Illustrations are used for reference only and can differ slightly from the actual luminaires installed. However, key components addressed in this information are represented as accurately as possible.
gothamlighting.com | 800-705-SERV (7378) | techsupport- downligh@acuitybrands.com |©2020 AcuityBrands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.
912-00481-001 REV. A
25
01/24
IVO Shallow Recess Downlight
INSTALLATION INSTRUCTIONS IVOS/IVOSQS REPLACEMENT PARTS
Safety
Identification
Housing Frame Installation
Wiring Diagrams
Flangeless (Optional)
Trim/LED Module
Inspection/Field Service
F. Inspection/Field Service LED Driver Replacement
1
To gain access to the LED driver, remove LED module/trim assembly following steps on pages 8 & 9.
2
Open junction box access door by rotating door latch to the right and swing door out of the way
NOTE: Illustrations are used for reference only and can differ slightly from
the actual luminaires installed. However, key components addressed in this
information are represented as accurately as possible.
gothamlighting.com | 800-705-SERV (7378) | techsupport-
downligh@acuitybrands.com |©2020 AcuityBrands Lighting, Inc. All Rights
Reserved. We reserve the right to change design, materials and finish in any
way that will not alter installed appearance or reduce function and
performance.
912-00481-001 REV. A
26
01/24
IVO Shallow Recess Downlight
INSTALLATION INSTRUCTIONS IVOS/IVOSQS REPLACEMENT PARTS
Safety
Identification
Housing Frame Installation
Wiring Diagrams
Flangeless (Optional)
Trim/LED Module
Inspection/Field Service
F. Inspection/Field Service LED Driver Replacement
3
Unlock driver sled locking latch by rotating latch to the left.
Latch Closed
Latch Open
NOTE: Illustrations are used for reference only and can differ slightly from
the actual luminaires installed. However, key components addressed in this
information are represented as accurately as possible.
gothamlighting.com | 800-705-SERV (7378) | techsupport-
downligh@acuitybrands.com |©2020 AcuityBrands Lighting, Inc. All Rights
Reserved. We reserve the right to change design, materials and finish in any
way that will not alter installed appearance or reduce function and
performance.
912-00481-001 REV. A
27
01/24
IVO Shallow Recess Downlight
INSTALLATION INSTRUCTIONS IVOS/IVOSQS REPLACEMENT PARTS
Safety
Identification
Housing Frame Installation
Wiring Diagrams
Flangeless (Optional)
Trim/LED Module
Inspection/Field Service
F. Inspection/Field Service LED Driver Replacement
4
Slide driver sled out of junction box and out through aperture. Release lead wires from driver. Remove screws holding driver. Install new driver and screws. Install driver
sled assembly in reverse order.
NOTE: Illustrations are used for reference only and can differ slightly from
the actual luminaires installed. However, key components addressed in this
information are represented as accurately as possible.
gothamlighting.com | 800-705-SERV (7378) | techsupport-
downligh@acuitybrands.com |©2020 AcuityBrands Lighting, Inc. All Rights
Reserved. We reserve the right to change design, materials and finish in any
way that will not alter installed appearance or reduce function and
performance.
912-00481-001 REV. A
28
01/24
IVO Shallow Recess Downlight
INSTALLATION INSTRUCTIONS IVOS/IVOSQS REPLACEMENT PARTS
Safety
Identification
Housing Frame Installation
Wiring Diagrams
Flangeless (Optional)
Trim/LED Module
Inspection/Field Service
F. Inspection/Field Service Optic Replacement
1
Remove finishing trim from LED module. Unlock optic assembly by twisting optic to the left.
NOTE: Illustrations are used for reference only and can differ slightly from
the actual luminaires installed. However, key components addressed in this
information are represented as accurately as possible.
gothamlighting.com | 800-705-SERV (7378) | techsupport-
downligh@acuitybrands.com |©2020 AcuityBrands Lighting, Inc. All Rights
Reserved. We reserve the right to change design, materials and finish in any
way that will not alter installed appearance or reduce function and
performance.
912-00481-001 REV. A
29
01/24
IVO Shallow Recess Downlight
INSTALLATION INSTRUCTIONS IVOS/IVOSQS REPLACEMENT PARTS
Safety
Identification
Housing Frame Installation
Wiring Diagrams
Flangeless (Optional)
Trim/LED Module
Inspection/Field Service
F. Inspection/Field Service Optic Replacement
2
Align locking features on backside of optic assembly with the recesses in the twist lock component (highlighted in blue)
Twist lock features
Twist lock recesses
NOTE: Illustrations are used for reference only and can differ slightly from
the actual luminaires installed. However, key components addressed in this
information are represented as accurately as possible.
gothamlighting.com | 800-705-SERV (7378) | techsupport-
downligh@acuitybrands.com |©2020 AcuityBrands Lighting, Inc. All Rights
Reserved. We reserve the right to change design, materials and finish in any
way that will not alter installed appearance or reduce function and
performance.
912-00481-001 REV. A
30
01/24
IVO Shallow Recess Downlight
INSTALLATION INSTRUCTIONS IVOS/IVOSQS REPLACEMENT PARTS
Safety
Identification
Housing Frame Installation
Wiring Diagrams
Flangeless (Optional)
Trim/LED Module
Inspection/Field Service
F. Inspection/Field Service Optic Replacement
3
Lock optic assembly by twisting to the right until fully seated. Install finishing trim to LED module.
NOTE: Illustrations are used for reference only and can differ slightly from
the actual luminaires installed. However, key components addressed in this
information are represented as accurately as possible.
gothamlighting.com | 800-705-SERV (7378) | techsupport-
downligh@acuitybrands.com |©2020 AcuityBrands Lighting, Inc. All Rights
Reserved. We reserve the right to change design, materials and finish in any
way that will not alter installed appearance or reduce function and
performance.
912-00481-001 REV. A
31
01/24
IVO Shallow Recess Downlight
INSTALLATION INSTRUCTIONS IVO4S/IVO6S
Safety
Identification
Housing Frame Installation
Wiring Diagrams
Flangeless (Optional)
Trim/LED Module
Inspection/Field Service
F. Inspection/Field Service NCH DMX, NLIGHT, NLIGHT AIR, ATRIUS
1 If luminaire is supplied with controls for DMX, NLIGHT, NLIGHT Air, or
Atrius®, make control wire connections inside accessory housing (Fig. 1). If
luminaire does not include, skip this step.
Accessory housing (DMX shown)
To inspect or service control wires, remove accessory
2
housing from frame. To remove, loosen screw, slide
accessory housing to the right and pull housing feet out of
frame slots and down through aperture (Fig. 2). Re-install in
reverse order.
Loosen screw
Fig. 1
Fig. 2
NOTE: Illustrations are used for reference only and can differ slightly from the actual luminaires installed. However, key components addressed in this information are represented as accurately as possible.
gothamlighting.com | 800-705-SERV (7378) | techsupport- downligh@acuitybrands.com |©2020 AcuityBrands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.
912-00481-001 REV. A
32
01/24
IVO Shallow Recess Downlight
INSTALLATION INSTRUCTIONS IVO4S/IVO6S
Safety
Identification
Housing Frame Installation
Wiring Diagrams
Flangeless (Optional)
Trim/LED Module
Inspection/Field Service
F. Inspection/Field Service 4″ CP/ICAT DMX, NLIGHT, NLIGHT AIR, E6WR
1 The IVO4S E6WR battery pack option is shown in Fig. 1. The LED driver, E6WR battery and accessory can be
2
First, disconnect the wire harnesses to the LED driver and accessory (Fig. 2). Unlock junction box door and swing
serviced through the aperture.
open. Unlock LED driver and accessory sleds, slide out and
down through aperture. Replace LED driver and/or
E6WR battery location
accessory. Re-install in reverse order.
inside primary junction box
Wire harness connectors
Top cover shown
Top cover shown as transparent
LED driver located opposite of primary junction box if
as transparent
E6WR option is selected
Fig. 1
DMX (no battery)/nLIGHT accessories
Fig. 2
NOTE: Illustrations are used for reference only and can differ slightly from the actual luminaires installed. However, key components addressed in this information are represented as accurately as possible.
gothamlighting.com | 800-705-SERV (7378) | techsupport- downligh@acuitybrands.com |©2020 AcuityBrands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.
912-00481-001 REV. A
33
01/24
IVO Shallow Recess Downlight
INSTALLATION INSTRUCTIONS IVO4S/IVO6S
Safety
Identification
Housing Frame Installation
Wiring Diagrams
Flangeless (Optional)
Trim/LED Module
Inspection/Field Service
F. Inspection/Field Service – 6″ CP/ICAT DMX, NLIGHT, NLIGHT AIR, E6WR
1 The IVO6 LED driver, E6WR battery pack and accessory options are shown in Fig. 1. The battery and accessories can be serviced through the aperture.
LED driver located opposite of primary junction box if E6WR option is selected
DMX/nLIGHT accessory (nIO shown)
2 First, disconnect the wire harnesses to the LED driver and accessory (Fig.
2). Remove brass thumb nuts holding LED driver and accessory brackets, slide
out and down through aperture. Replace LED driver and/or accessory. Re-install
in reverse order.
Wire harness connectors
E6WR battery location
Fig. 1
inside primary junction box
Brass thumb nuts
Fig. 2
NOTE: Illustrations are used for reference only and can differ slightly from the actual luminaires installed. However, key components addressed in this information are represented as accurately as possible.
gothamlighting.com | 800-705-SERV (7378) | techsupport- downligh@acuitybrands.com |©2020 AcuityBrands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.
912-00481-001 REV. A
34
01/24
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>