Acuity Brands IVO4S NCH 4 Square Downlight Installation Guide

August 28, 2024
Acuity Brands

IVO4S NCH 4 Square Downlight

“`html

Specifications

  • Product Name: IVO Shallow Recess Downlight

  • Model: IVO4S NCH, IVO4S CP/ICAT, IVO6S NCH, IVO6S CP/ICAT

  • Options: Flangeless, Emergency Lighting, Controls
    (DMX/NLIGHT/NLIGHTER/NLTAIR2/NLTAIREM2)

  • Trim Options: Parabolic Trim, Lensed Wallwash Trim

  • Revision: A

  • Date: 01/24

Product Usage Instructions

Safety

Before installation or maintenance, ensure the power is switched
off to prevent electric shock.

Identification

Refer to the product model number and options to identify the
specific downlight and trim type.

Housing Frame Installation

Follow the provided installation instructions to securely mount
the housing frame in the ceiling.

Wiring Diagrams

Consult the wiring diagrams to correctly connect the downlight
to the power source.

Flangeless (Optional)

If using the flangeless option, ensure proper alignment and
installation for a seamless look.

Trim/LED Module

Install the selected trim or LED module according to the
manufacturer’s instructions for desired lighting effects.

Inspection/Field Service

Regularly inspect the downlight for any damage or malfunction.
Seek professional service if needed.

FAQ

Q: Can I install the downlight without a housing frame?

A: No, it is important to install the housing frame as per the
instructions for safe and proper operation.

Q: Can I use controls with all models of the downlight?

A: Controls can be used with specific models mentioned in the
product identification section. Refer to the options available for
each model.

Q: How do I change the trim of the downlight?

A: Follow the provided guidelines to safely remove and replace
the trim of the downlight for different lighting effects.

“`

IVO Shallow Recess Downlight
INSTALLATION INSTRUCTIONS ­ IVO4S/IVO6S

Safety

Identification

Housing Frame Installation

Wiring Diagrams

Flangeless (Optional)

Trim/LED Module

Inspection/Field Service

gothamlighting.com | 800-705-SERV (7378) | techsupport- downligh@acuitybrands.com |©2020 AcuityBrands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.

912-00481-001 REV. A 01/24

1

IVO Shallow Recess Downlight
INSTALLATION INSTRUCTIONS ­ IVO4S/IVO6S

Safety

Identification

Housing Frame Installation

Wiring Diagrams

Flangeless (Optional)

Trim/LED Module

Inspection/Field Service

gothamlighting.com | 800-705-SERV (7378) | techsupport- downligh@acuitybrands.com |©2020 AcuityBrands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.

912-00481-001 REV. A 01/24

2

IVO Shallow Recess Downlight
INSTALLATION INSTRUCTIONS ­ IVO4S/IVO6S

Safety

Identification

Housing Frame Installation

Wiring Diagrams

Flangeless (Optional)

Trim/LED Module

Inspection/Field Service

gothamlighting.com | 800-705-SERV (7378) | techsupport- downligh@acuitybrands.com |©2020 AcuityBrands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.

912-00481-001 REV. A 01/24

3

IVO Shallow Recess Downlight
INSTALLATION INSTRUCTIONS ­ IVO4S/IVO6S

Safety

Identification

Housing Frame Installation

Wiring Diagrams

Flangeless (Optional)

Trim/LED Module

Inspection/Field Service

gothamlighting.com | 800-705-SERV (7378) | techsupport- downligh@acuitybrands.com |©2020 AcuityBrands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.

912-00481-001 REV. A 01/24

4

IVO Shallow Recess Downlight
INSTALLATION INSTRUCTIONS ­ IVO4S/IVO6S

Safety

Identification

Housing Frame Installation

Wiring Diagrams

Flangeless (Optional)

Trim/LED Module

Inspection/Field Service

gothamlighting.com | 800-705-SERV (7378) | techsupport- downligh@acuitybrands.com |©2020 AcuityBrands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.

912-00481-001 REV. A 01/24

5

IVO Shallow Recess Downlight
INSTALLATION INSTRUCTIONS ­ IVO4S/IVO6S

Safety

Identification

Housing Frame Installation

Wiring Diagrams

Flangeless (Optional)

Trim/LED Module

Inspection/Field Service

A. Identification – IVO Shallow Recess Downlights

IVO4S NCH

IVO4S CP/ICAT IVO4S NCH Emergency E6WR

IVO4S NCH with Controls (DMX/NLIGHT/NLIGHTER/NLTAIR2/NLTAIREM2)

IVO4S NCH Emergency E10WCPR/15WCPR/GTD (access above ceiling required)

NOTE: Illustrations are used for reference only and can differ slightly from the actual luminaires installed. However, key components addressed in this information are represented as accurately as possible.

gothamlighting.com | 800-705-SERV (7378) | techsupport- downligh@acuitybrands.com |©2020 AcuityBrands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.

912-00481-001 REV. A 01/24

6

IVO Shallow Recess Downlight
INSTALLATION INSTRUCTIONS ­ IVO4S/IVO6S

Safety

Identification

Housing Frame Installation

Wiring Diagrams

Flangeless (Optional)

Trim/LED Module

Inspection/Field Service

A. Identification – IVO Shallow Recess Downlights

IVO6S NCH

IVO6S NCH Emergency E10WCPR/15WCPR/GTD (access above ceiling required)

IVO6S NCH with Controls (DMX/NLIGHT/NLIGHTER/NLTAIR2/NLTAIREM2)
Change to open frame

IVO6S CP/ICAT IVO6S NCH Emergency E6WR

NOTE: Illustrations are used for reference only and can differ slightly from the actual luminaires installed. However, key components addressed in this information are represented as accurately as possible.

gothamlighting.com | 800-705-SERV (7378) | techsupport- downligh@acuitybrands.com |©2020 AcuityBrands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.

912-00481-001 REV. A 01/24

7

IVO Shallow Recess Downlight
INSTALLATION INSTRUCTIONS ­ IVO4S/IVO6S

Safety

Identification

Housing Frame Installation

Wiring Diagrams

Flangeless (Optional)

Trim/LED Module

Inspection/Field Service

A. Identification – IVO Shallow Recess Trims

IVO4S P (Parabolic Trim)

IVO4SQS P (Parabolic Trim)

IVO4S LW (Lensed Wallwash Trim)

IVO4SQS LW (Lensed Wallwash Trim)

NOTE: Illustrations are used for reference only and can differ slightly from the actual luminaires installed. However, key components addressed in this information are represented as accurately as possible.

gothamlighting.com | 800-705-SERV (7378) | techsupport- downligh@acuitybrands.com |©2020 AcuityBrands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.

912-00481-001 REV. A 01/24

8

IVO Shallow Recess Downlight
INSTALLATION INSTRUCTIONS ­ IVO4S/IVO6S

Safety

Identification

Housing Frame Installation

Wiring Diagrams

Flangeless (Optional)

Trim/LED Module

Inspection/Field Service

A. Identification – IVO Shallow Recess Trims

IVO6S P (Parabolic Trim)

IVO6SQS P (Parabolic Trim)

IVO6S LW (Lensed Wallwash Trim)

IVO6SQS LW (Lensed Wallwash Trim)

NOTE: Illustrations are used for reference only and can differ slightly from the actual luminaires installed. However, key components addressed in this information are represented as accurately as possible.

gothamlighting.com | 800-705-SERV (7378) | techsupport- downligh@acuitybrands.com |©2020 AcuityBrands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.

912-00481-001 REV. A 01/24

9

IVO Shallow Recess Downlight
INSTALLATION INSTRUCTIONS ­ IVO4S/IVO6S

Safety

Identification

Housing Frame Installation

Wiring Diagrams

Flangeless (Optional)

A. Identification ­ Flangeless Trim Adapter

Trim/LED Module

Inspection/Field Service

IVO4ADPT FL (Flangeless Trim Adapter)

IVO4SQADPT FL (Flangeless Trim Adapter)

IVO6ADPT FL (Flangeless Trim Adapter)

IVO6SQADPT (Flangeless Trim Adapter)

NOTE: Illustrations are used for reference only and can differ slightly from the actual luminaires installed. However, key components addressed in this information are represented as accurately as possible.

gothamlighting.com | 800-705-SERV (7378) | techsupport- downligh@acuitybrands.com |©2020 AcuityBrands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.

912-00481-001 REV. A

10

01/24

IVO Shallow Recess Downlight
INSTALLATION INSTRUCTIONS ­ IVO4S/IVO6S

Safety

Identification

Housing Frame Installation

Wiring Diagrams

Flangeless (Optional)

Trim/LED Module

Inspection/Field Service

B. NCH Housing Installation – IVO Shallow Recess Downlights

1

For best results, cut ceiling opening as specified: 4″ Flanged ceiling opening (round): 5″ dia. (12.7 cm)

4″ Flanged ceiling opening (square): 5″ across flats (12.7 cm)

6″ Flanged ceiling opening (round): 7-1/8″ dia. (18.1 cm)

6″ Flanged ceiling opening (square): 7-1/8″ across flats (18.1 cm)

Ceiling thickness range is from 5/8″ to 2″.

NOTE: For flangeless installation, cut ceiling opening as specified: 4″ Flangeless ceiling opening (round): 5-1/4″ dia. (13.3 cm) 4″ Flangeless ceiling opening (square): 5-1/4″ across flats (13.3 cm) 6″ Flangeless ceiling opening (round): 7-3/8″ dia. (18.7 cm) 6″ Flangeless ceiling opening (square): 7-3/8″ across flats (18.7 cm)
Please refer to flangeless adapter instructions prior to housing
installation (pages 18-20).

Fixture should be used in ceilings with 25°C ambient temperature as standard.

Non-IC rated luminaires should be installed with 1/2″ clearance on all sides from non-combustible materials and with 3″ clearance on all sides from insulation (unless marked spacing noted otherwise). If fixtures are ICAT and labeled as inherently protected, insulation may be applied directly onto fixture enclosure.

Insert the supplied mounting bars or chosen mounting
2 bar style into “Universal Mounting Brackets” on each side of the fixture (Fig 1). (See below for acceptable mounting bar styles.)
Fig. 1
Universal Mounting Bracket: Universal mounting bracket also accepts various mounting bars (supplied separately).

¾” C

1-1/2″ C

CHANNEL

CHANNEL

NOTE: Illustrations are used for reference only and can differ slightly from the actual luminaires installed.

However, key components addressed in this information are represented as accurately as possible.

½” OR ¾” ½” CONDUIT ½” ANGLE

FLAT STRAP

BAR

gothamlighting.com | 800-705-SERV (7378) | techsupport- downligh@acuitybrands.com |©2020 AcuityBrands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.

912-00481-001 REV. A

11

01/24

IVO Shallow Recess Downlight
INSTALLATION INSTRUCTIONS ­ IVO4S/IVO6S

Safety

Identification

Housing Frame Installation

Wiring Diagrams

Flangeless (Optional)

Trim/LED Module

Inspection/Field Service

B. NCH Housing Installation – IVO Shallow Recess Downlights

3

Install mounting frame to ceiling, securing bars to t-bar or joists per local code. To lock mounting bars horizontally,

use channel locks to compress the locking tabs as shown in

Fig. 2

4 If necessary, adjust the mounting frame vertically to align the bottom edge of the aperture flush or slightly above the ceiling plane (Fig. 3). Vertical slot allows for 1-1/8″ of adjustment. Retighten wing nut when finished.

Fig. 2

Fig. 3

LOCKING TABS

NOTE: Illustrations are used for reference only and can differ slightly from the actual luminaires installed. However, key components addressed in this information are represented as accurately as possible.

gothamlighting.com | 800-705-SERV (7378) | techsupport- downligh@acuitybrands.com |©2020 AcuityBrands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.

912-00481-001 REV. A

12

01/24

IVO Shallow Recess Downlight
INSTALLATION INSTRUCTIONS ­ IVO4S/IVO6S

Safety

Identification

Housing Frame Installation

Wiring Diagrams

Flangeless (Optional)

Trim/LED Module

Inspection/Field Service

B. NCH Housing Installation – IVO Shallow Recess Downlights

5

Remove a knockout on rear of junction box to feed supply power to fixture (Fig. 4). Push-in conduit fittings

are strongly recommended. Supply wire must meet

applicable electrical codes and be rated for a minimum

of 90°C. Junction box is thru-wire rated for 8 – No. 12

AWG conductors (4in-4out). Appropriate control wires to

be provided by installer in accordance with selected

driver option.

6

Open junction box access door by rotating door latch to the right and swing door out of the way (Fig. 5).

Fig. 4
Dual Knock-outs provided for 1/2″ and 3/4″ conduit fittings

Fig. 5

NOTE: Illustrations are used for reference only and can differ slightly from the actual luminaires installed. However, key components addressed in this information are represented as accurately as possible.

gothamlighting.com | 800-705-SERV (7378) | techsupport- downligh@acuitybrands.com |©2020 AcuityBrands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.

912-00481-001 REV. A

13

01/24

IVO Shallow Recess Downlight
INSTALLATION INSTRUCTIONS ­ IVO4S/IVO6S

Safety

Identification

Housing Frame Installation

Wiring Diagrams

Flangeless (Optional)

Trim/LED Module

Inspection/Field Service

B. NCH Housing Installation – IVO Shallow Recess Downlights

Pull supply wires and driver leads through aperture if
7 there is not sufficient plenum space to work. Gotham recommends supply leads be at least 7″ long to reach through aperture opening (Fig. 6). Complete necessary splices according to wiring diagram for selected fixture options (See Pages 15-17). (0-10V Option Shown)

8

Push all wires back inside splice box ensuring no wires remain outside junction box opening. Swing

junction box access door closed and secure with

latch. (Fig. 7)

Fig. 6

Fig. 7

gothamlighting.com | 800-705-SERV (7378) | techsupport- downligh@acuitybrands.com |©2020 AcuityBrands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.

912-00481-001 REV. A

14

01/24

IVO Shallow Recess Downlight
INSTALLATION INSTRUCTIONS ­ IVO4S/IVO6S

Safety

Identification

Housing Frame Installation

Wiring Diagrams

Flangeless (Optional)

Trim/LED Module

Inspection/Field Service

C. Wiring Diagrams – IVO Shallow Recess Downlights
EZ/ZT (0-10V Dimming)

ELV (Phase Dimming) DALI

gothamlighting.com | 800-705-SERV (7378) | techsupport- downligh@acuitybrands.com |©2020 AcuityBrands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.

912-00481-001 REV. A

15

01/24

IVO Shallow Recess Downlight
INSTALLATION INSTRUCTIONS ­ IVO4S/IVO6S

Safety

Identification

Housing Frame Installation

Wiring Diagrams

Flangeless (Optional)

Trim/LED Module

Inspection/Field Service

C. Wiring Diagrams – IVO Shallow Recess Downlights
DMX

E6WR

E10WCPR/E15WCPR

gothamlighting.com | 800-705-SERV (7378) | techsupport- downligh@acuitybrands.com |©2020 AcuityBrands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.

912-00481-001 REV. A

16

01/24

IVO Shallow Recess Downlight
INSTALLATION INSTRUCTIONS ­ IVO4S/IVO6S

Safety

Identification

Housing Frame Installation

Wiring Diagrams

Flangeless (Optional)

Trim/LED Module

Inspection/Field Service

C. Wiring Diagrams – IVO Shallow Recess Downlights
NLIGHT

NLTAIR2 NLIGHTER

NLTAIREM2

gothamlighting.com | 800-705-SERV (7378) | techsupport- downligh@acuitybrands.com |©2020 AcuityBrands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.

912-00481-001 REV. A

17

01/24

IVO Shallow Recess Downlight
INSTALLATION INSTRUCTIONS ­ IVO4S/IVO6S

Safety

Identification

Housing Frame Installation

Wiring Diagrams

Flangeless (Optional)

Trim/LED Module

Inspection/Field Service

D. Flangeless Trim Adapter Installation (Optional) – IVO Shallow Recess Downlights
If flangeless trims are specified, a Gotham flangeless adapter must be used. For self flanged applications, skip to Trim/LED module installation instructions (pages 21­23).
Gotham flangeless adapters are intended to be used only with Gotham new construction and remodel housings and corresponding trims.
For best results, use Gotham flangeless adapters with new, unpainted, paper- faced gypsum board only. Use of these adapters with other ceiling materials is not recommended.
Note: For best appearance, at minimum a Level 4 drywall finish for textured ceilings and a Level 5 drywall finish for flat ceilings is recommended. In addition, use of a setting-type joint compound such as Sheetrock® brand Durabond® is recommended to increase durability and prevent the formation of hairline cracks over time.
Install housing based on mounting frame installation instructions
1 For flange-less installation, cut ceiling opening as specified: 4″ Round & Square Flangeless Ceiling opening (NCH & RM): 5-1/4″ (13.3 cm) 6″ Round & Square Flangeless Ceiling opening (NCH & RM): 7-3/8″ (18.7 cm)
2 Adhere flangeless adapter to ceiling using joint compound, such as Sheetrock® brand Durabond®, or adhesive.

NOTE: Illustrations are used for reference only and can differ slightly from the actual luminaires installed. However, key components addressed in this information are represented as accurately as possible.

gothamlighting.com | 800-705-SERV (7378) | techsupport- downligh@acuitybrands.com |©2020 AcuityBrands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.

912-00481-001 REV. A

18

01/24

IVO Shallow Recess Downlight
INSTALLATION INSTRUCTIONS ­ IVO4S/IVO6S

Safety

Identification

Housing Frame Installation

Wiring Diagrams

Flangeless (Optional)

Trim/LED Module

Inspection/Field Service

D. Flangeless Trim Adapter Installation (Optional) – IVO Shallow Recess Downlights

Remove any excess compound or adhesive, before allowing to
3 dry, from the front of the flangeless adapter.

4 Apply joint compound to flangeless trim adapter up to the edge of the paint shield. Smooth and feather out. Repeat until all edges surrounding paint shield are filled. Remove any excess compound before allowing to dry.

NOTE: Illustrations are used for reference only and can differ slightly from the actual luminaires installed. However, key components addressed in this information are represented as accurately as possible.

gothamlighting.com | 800-705-SERV (7378) | techsupport- downligh@acuitybrands.com |©2020 AcuityBrands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.

912-00481-001 REV. A

19

01/24

IVO Shallow Recess Downlight
INSTALLATION INSTRUCTIONS ­ IVO4S/IVO6S

Safety

Identification

Housing Frame Installation

Wiring Diagrams

Flangeless (Optional)

Trim/LED Module

Inspection/Field Service

D. Flangeless Trim Adapter Installation (Optional) – IVO Shallow Recess Downlights

5 Sand until the joint compound is feathered to an even transition between the flangeless adapter and drywall.

6 After painting is completed, remove any excess paint or joint compound from the inside surfaces where the trim flange will rest. Install trim.

Trim Installed

NOTE: Illustrations are used for reference only and can differ slightly from the actual luminaires installed. However, key components addressed in this information are represented as accurately as possible.

gothamlighting.com | 800-705-SERV (7378) | techsupport- downligh@acuitybrands.com |©2020 AcuityBrands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.

912-00481-001 REV. A

20

01/24

IVO Shallow Recess Downlight
INSTALLATION INSTRUCTIONS ­ IVO4S/IVO6S

Safety

Identification

Housing Frame Installation

Wiring Diagrams

Flangeless (Optional)

Trim/LED Module

Inspection/Field Service

E. Trim/LED Module Installation – IVO Shallow Recess Downlights

If LED module was disconnected from mounting
1 frame in previous step, open quick disconnect
enclosure door through aperture (Fig. 1).
Quick disconnect enclosure door

Connect the LED module input wire connector to
2 the driver output connector inside the quick
disconnect enclosure. Place the conduit into quick
disconnect enclosure recess and snap door closed
to properly strain relief connection (Fig. 2).

Fig. 1

Fig. 2

Fig. 7

NOTE: Illustrations are used for reference only and can differ slightly from the actual luminaires installed. However, key components addressed in this information are represented as accurately as possible.

gothamlighting.com | 800-705-SERV (7378) | techsupport- downligh@acuitybrands.com |©2020 AcuityBrands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.

912-00481-001 REV. A

21

01/24

IVO Shallow Recess Downlight
INSTALLATION INSTRUCTIONS ­ IVO4S/IVO6S

Safety

Identification

Housing Frame Installation

Wiring Diagrams

Flangeless (Optional)

Trim/LED Module

Inspection/Field Service

E. Trim/LED Module Installation – IVO Shallow Recess Downlights

3

With the LED module hanging through the aperture, hold LED module in one hand. With other hand, align the

notches in trim with the twist lock component (highlighted

in blue) inside the LED Module (Fig 3). Ensure the trim is

fully seated. Rotate the trim clockwise until locked into

place (Fig 4).

Fig. 3

Fig. 4

NOTE: Illustrations are used for reference only and can differ slightly from the actual luminaires installed. However, key components addressed in this information are represented as accurately as possible.

gothamlighting.com | 800-705-SERV (7378) | techsupport- downligh@acuitybrands.com |©2020 AcuityBrands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.

912-00481-001 REV. A

22

01/24

IVO Shallow Recess Downlight
INSTALLATION INSTRUCTIONS ­ IVO4S/IVO6S

Safety

Identification

Housing Frame Installation

Wiring Diagrams

Flangeless (Optional)

Trim/LED Module

Inspection/Field Service

E. Trim/LED Module Installation – IVO Shallow Recess Downlights

*Protected by U.S. Patent No. 10,724,717 B2

4

Open retention springs* on LED module and hold upright in vertical position while inserting LED module through aperture and allowing springs to pull trim tight to

ceiling. For wall wash style trims, rotate LED module so that light is directed at wall to

be illuminated.

Flexible conduit not shown

NOTE: Illustrations are used for reference only and can differ slightly from the actual luminaires installed. However, key components addressed in this information are represented as accurately as possible.

gothamlighting.com | 800-705-SERV (7378) | techsupport- downligh@acuitybrands.com |©2020 AcuityBrands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.

912-00481-001 REV. A

23

01/24

IVO Shallow Recess Downlight
INSTALLATION INSTRUCTIONS ­ IVO4S/IVO6S

Safety

Identification

Housing Frame Installation

Wiring Diagrams

Flangeless (Optional)

Trim/LED Module

Inspection/Field Service

F. Inspection/Field Service – IVO Shallow Recess Downlights

CAUTION! Use care when removing the LED module for

!

maintenance purposes. Support the spring assemblies during removal to prevent injury.

1

To access driver, optic, or LED light engine, remove LED module by gripping trim around flange edge and

begin to pull downward. Retention spring housings will

catch on interior edge of aperture and stop. When

springs stop on aperture edge, use fingers to support

spring housings in upright position while continuing to

pull LED module out of aperture. (Fig. 1)

Fig. 1 (flexible conduit not shown)

NOTE: Illustrations are used for reference only and can differ slightly from the actual luminaires installed. However, key components addressed in this information are represented as accurately as possible.

gothamlighting.com | 800-705-SERV (7378) | techsupport- downligh@acuitybrands.com |©2020 AcuityBrands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.

912-00481-001 REV. A

24

01/24

IVO Shallow Recess Downlight
INSTALLATION INSTRUCTIONS ­ IVOS/IVOSQS REPLACEMENT PARTS

Safety

Identification

Housing Frame Installation

Wiring Diagrams

Flangeless (Optional)

Trim/LED Module

Inspection/Field Service

F. Inspection/Field Service ­ LED Module Replacement

2

Open quick disconnect enclosure door through aperture.

Connector latch

3

Remove conduit from strain relief recess of quick disconnect enclosure. Depress connector latch to

disconnect while supporting LED module to prevent from

falling. Connect new LED module input wire connector to

the driver output connector inside the quick disconnect

enclosure. Place the conduit into quick disconnect

enclosure recess and snap door closed to properly strain

relief connection. Re-install LED module into fixture.

Quick disconnect enclosure door

Conduit strain relief recess

NOTE: Illustrations are used for reference only and can differ slightly from the actual luminaires installed. However, key components addressed in this information are represented as accurately as possible.

gothamlighting.com | 800-705-SERV (7378) | techsupport- downligh@acuitybrands.com |©2020 AcuityBrands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.

912-00481-001 REV. A

25

01/24

IVO Shallow Recess Downlight
INSTALLATION INSTRUCTIONS ­ IVOS/IVOSQS REPLACEMENT PARTS

Safety

Identification

Housing Frame Installation

Wiring Diagrams

Flangeless (Optional)

Trim/LED Module

Inspection/Field Service

F. Inspection/Field Service ­ LED Driver Replacement

1

To gain access to the LED driver, remove LED module/trim assembly following steps on pages 8 & 9.

2

Open junction box access door by rotating door latch to the right and swing door out of the way

NOTE: Illustrations are used for reference only and can differ slightly from the actual luminaires installed. However, key components addressed in this information are represented as accurately as possible.
gothamlighting.com | 800-705-SERV (7378) | techsupport- downligh@acuitybrands.com |©2020 AcuityBrands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.

912-00481-001 REV. A

26

01/24

IVO Shallow Recess Downlight
INSTALLATION INSTRUCTIONS ­ IVOS/IVOSQS REPLACEMENT PARTS

Safety

Identification

Housing Frame Installation

Wiring Diagrams

Flangeless (Optional)

Trim/LED Module

Inspection/Field Service

F. Inspection/Field Service ­ LED Driver Replacement

3

Unlock driver sled locking latch by rotating latch to the left.

Latch Closed

Latch Open

NOTE: Illustrations are used for reference only and can differ slightly from the actual luminaires installed. However, key components addressed in this information are represented as accurately as possible.
gothamlighting.com | 800-705-SERV (7378) | techsupport- downligh@acuitybrands.com |©2020 AcuityBrands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.

912-00481-001 REV. A

27

01/24

IVO Shallow Recess Downlight
INSTALLATION INSTRUCTIONS ­ IVOS/IVOSQS REPLACEMENT PARTS

Safety

Identification

Housing Frame Installation

Wiring Diagrams

Flangeless (Optional)

Trim/LED Module

Inspection/Field Service

F. Inspection/Field Service ­ LED Driver Replacement

4

Slide driver sled out of junction box and out through aperture. Release lead wires from driver. Remove screws holding driver. Install new driver and screws. Install driver

sled assembly in reverse order.

NOTE: Illustrations are used for reference only and can differ slightly from the actual luminaires installed. However, key components addressed in this information are represented as accurately as possible.
gothamlighting.com | 800-705-SERV (7378) | techsupport- downligh@acuitybrands.com |©2020 AcuityBrands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.

912-00481-001 REV. A

28

01/24

IVO Shallow Recess Downlight
INSTALLATION INSTRUCTIONS ­ IVOS/IVOSQS REPLACEMENT PARTS

Safety

Identification

Housing Frame Installation

Wiring Diagrams

Flangeless (Optional)

Trim/LED Module

Inspection/Field Service

F. Inspection/Field Service ­ Optic Replacement

1

Remove finishing trim from LED module. Unlock optic assembly by twisting optic to the left.

NOTE: Illustrations are used for reference only and can differ slightly from the actual luminaires installed. However, key components addressed in this information are represented as accurately as possible.
gothamlighting.com | 800-705-SERV (7378) | techsupport- downligh@acuitybrands.com |©2020 AcuityBrands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.

912-00481-001 REV. A

29

01/24

IVO Shallow Recess Downlight
INSTALLATION INSTRUCTIONS ­ IVOS/IVOSQS REPLACEMENT PARTS

Safety

Identification

Housing Frame Installation

Wiring Diagrams

Flangeless (Optional)

Trim/LED Module

Inspection/Field Service

F. Inspection/Field Service ­ Optic Replacement

2

Align locking features on backside of optic assembly with the recesses in the twist lock component (highlighted in blue)

Twist lock features

Twist lock recesses

NOTE: Illustrations are used for reference only and can differ slightly from the actual luminaires installed. However, key components addressed in this information are represented as accurately as possible.
gothamlighting.com | 800-705-SERV (7378) | techsupport- downligh@acuitybrands.com |©2020 AcuityBrands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.

912-00481-001 REV. A

30

01/24

IVO Shallow Recess Downlight
INSTALLATION INSTRUCTIONS ­ IVOS/IVOSQS REPLACEMENT PARTS

Safety

Identification

Housing Frame Installation

Wiring Diagrams

Flangeless (Optional)

Trim/LED Module

Inspection/Field Service

F. Inspection/Field Service ­ Optic Replacement

3

Lock optic assembly by twisting to the right until fully seated. Install finishing trim to LED module.

NOTE: Illustrations are used for reference only and can differ slightly from the actual luminaires installed. However, key components addressed in this information are represented as accurately as possible.
gothamlighting.com | 800-705-SERV (7378) | techsupport- downligh@acuitybrands.com |©2020 AcuityBrands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.

912-00481-001 REV. A

31

01/24

IVO Shallow Recess Downlight
INSTALLATION INSTRUCTIONS ­ IVO4S/IVO6S

Safety

Identification

Housing Frame Installation

Wiring Diagrams

Flangeless (Optional)

Trim/LED Module

Inspection/Field Service

F. Inspection/Field Service ­ NCH DMX, NLIGHT, NLIGHT AIR, ATRIUS

1 If luminaire is supplied with controls for DMX, NLIGHT, NLIGHT Air, or Atrius®, make control wire connections inside accessory housing (Fig. 1). If luminaire does not include, skip this step.
Accessory housing (DMX shown)

To inspect or service control wires, remove accessory

2

housing from frame. To remove, loosen screw, slide

accessory housing to the right and pull housing feet out of

frame slots and down through aperture (Fig. 2). Re-install in

reverse order.

Loosen screw

Fig. 1

Fig. 2

NOTE: Illustrations are used for reference only and can differ slightly from the actual luminaires installed. However, key components addressed in this information are represented as accurately as possible.

gothamlighting.com | 800-705-SERV (7378) | techsupport- downligh@acuitybrands.com |©2020 AcuityBrands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.

912-00481-001 REV. A

32

01/24

IVO Shallow Recess Downlight
INSTALLATION INSTRUCTIONS ­ IVO4S/IVO6S

Safety

Identification

Housing Frame Installation

Wiring Diagrams

Flangeless (Optional)

Trim/LED Module

Inspection/Field Service

F. Inspection/Field Service ­ 4″ CP/ICAT DMX, NLIGHT, NLIGHT AIR, E6WR

1 The IVO4S E6WR battery pack option is shown in Fig. 1. The LED driver, E6WR battery and accessory can be

2

First, disconnect the wire harnesses to the LED driver and accessory (Fig. 2). Unlock junction box door and swing

serviced through the aperture.

open. Unlock LED driver and accessory sleds, slide out and

down through aperture. Replace LED driver and/or

E6WR battery location

accessory. Re-install in reverse order.

inside primary junction box

Wire harness connectors

Top cover shown

Top cover shown as transparent

LED driver located opposite of primary junction box if

as transparent

E6WR option is selected

Fig. 1
DMX (no battery)/nLIGHT accessories

Fig. 2

NOTE: Illustrations are used for reference only and can differ slightly from the actual luminaires installed. However, key components addressed in this information are represented as accurately as possible.

gothamlighting.com | 800-705-SERV (7378) | techsupport- downligh@acuitybrands.com |©2020 AcuityBrands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.

912-00481-001 REV. A

33

01/24

IVO Shallow Recess Downlight
INSTALLATION INSTRUCTIONS ­ IVO4S/IVO6S

Safety

Identification

Housing Frame Installation

Wiring Diagrams

Flangeless (Optional)

Trim/LED Module

Inspection/Field Service

F. Inspection/Field Service – 6″ CP/ICAT DMX, NLIGHT, NLIGHT AIR, E6WR

1 The IVO6 LED driver, E6WR battery pack and accessory options are shown in Fig. 1. The battery and accessories can be serviced through the aperture.

LED driver located opposite of primary junction box if E6WR option is selected

DMX/nLIGHT accessory (nIO shown)

2 First, disconnect the wire harnesses to the LED driver and accessory (Fig. 2). Remove brass thumb nuts holding LED driver and accessory brackets, slide out and down through aperture. Replace LED driver and/or accessory. Re-install in reverse order.
Wire harness connectors

E6WR battery location

Fig. 1

inside primary junction box

Brass thumb nuts

Fig. 2

NOTE: Illustrations are used for reference only and can differ slightly from the actual luminaires installed. However, key components addressed in this information are represented as accurately as possible.

gothamlighting.com | 800-705-SERV (7378) | techsupport- downligh@acuitybrands.com |©2020 AcuityBrands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.

912-00481-001 REV. A

34

01/24

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Acuity Brands User Manuals

Related Manuals