Myers SX50 Sump Pumps Installation Guide

June 17, 2024
Myers

Myers SX50 Sump Pumps

Myers-SX50-Sump-Pumps-
product

WARNING! IMPORTANT SAFETY INSTRUCTIONS! READ CAREFULLY BEFORE INSTALLATION. This manual contains important information for the safe use of this product. Read this manual completely before using this product and refer to it often for continued safe product use. DO NOT THROW AWAY OR LOSE THIS MANUAL. Keep it in a safe place so that you may refer to it often.

GENERAL

  1. Most accidents can be avoided by using COMMON SENSE.

  2. Read the operation and maintenance instructions manual supplied with the pump.

  3. Do not wear loose clothing that can become entangled in the impeller or other moving parts.

  4. This pump is designed to handle materials that could cause illness or disease through direct exposure. Wear adequate protective clothing when working on the pump or piping.
    ELECTRICAL

  5. To reduce the risk of electrical shock, pump must be properly grounded in accordance with the National Electric Code and all applicable state and local codes and ordinances.

  6. To reduce risk of electrical shock, disconnect the pump from the power source before handling or servicing.

  7. Any wiring to be done on pumps should be done by a qualified electrician.

  8. Never operate a pump with a power cord that has frayed or brittle insulation.

  9. Never let cords or plugs lie in water.

  10. Never handle connected power cords with wet hands.
    PUMPS

  11. Pump builds up heat and pressure during operation; allow time for pump to cool before handling or servicing.

  12. Only qualified personnel should install, operate or repair pump.

  13. Keep clear of suction and discharge openings. DO NOT insert fingers in pump with power connected.

  14. Do not pump hazardous material not recommended for pump (flammable, caustic, etc.).

  15. Make sure lifting handles are securely fastened each time before lifting.

  16. Do not lift pump by the power cord.

  17. Do not exceed manufacturer’s recommendation for maximum performance, as this could cause the motor to overheat.

  18. Secure the pump in its operating position so it cannot tip over, fall or slide.

  19. Keep hands and feet away from impeller when power is connected.

  20. Submersible sump pumps are not approved for use in swimming pools, recreational water installations, decorative fountains or any installation where human contact with the pumped fluid is common.

  21. Do not operate pump without safety devices in place.

  22. For hazardous locations, use pumps that are listed and classified for such locations.

IMPORTANT! Myers is not responsible for losses, injury or death resulting from a failure to observe these safety precautions, misuse or abuse of pumps or equipment.

GENERAL INFORMATION

  • Pump Models: These instructions cover the installation and service of the Myers SX50 and SX50H series submersible sump pumps. The motors are CSA listed for hazardous sewage locations Class 1, Div. 1, Group D.

  • Motor HP & Voltages: The SX50/SX50H sump pumps are offered in single and three phase. Voltages will vary according to the application and can be seen in the tables in this manual.

  • Electrical Controls: All of these pump models must be used with a control panel. Myers built control panels are designed to supply the correct electrical controls, motor starting equipment and include
    the circuitry for moisture and heat sensors. It is recommended that a Myers- built control panel be used so that all warranties apply.

  • General Construction: The SX50/SX50H motor construction is designed to meet CSA requirements for Class 1, Group D sewage applications. These models are approved and nameplated with a CSA file number. A cross sectional view of the internal workings of the pumps can be seen . The motor chamber and seal chamber are filled with a high dielectric type oil for improved lubrication and heat transfer of the bearings and motor. Since the bearings have been designed for 50,000 hours of life, the oil should never require replacement under normal operating conditions. An air space above the oil level in both the seal and motor chambers is provided to allow for the expansion of the oil when at operating temperature. The power and control lines are sealed and strain relieved on the outside entrance with a standard cord grip, and internally through the use of a dielectric potting resin surrounding the electrical wires.
    Internal connection wiring diagrams are shown in Figure 8. All of the pump fasteners and shafts are made from corrosion resistant stainless steel, while the pump castings are made of ASTM A-48 Class 30 cast iron, and the multivane vortex impellers are made from Class 20 cast iron.

  • General Installation: Various configurations and methods of plumbing this series of sump pumps may be used.

  • Note: If the SX50/SX50H hazardous location pumps are used in conjunction with a rail lift-out system, it must be a UL or CSA listed nonsparking system for hazardous locations.

  • IMPORTANT: If the following guidelines are not followed, the CSA hazardous location listing is void.

  • These pumps are to be used for handling septic tank effluent, sewage, and storm water only. Do not use in other hazardous locations. These motors must be repaired and serviced only at a Myers authorized service center or at the Myers factory. Any unauthorized field repair voids warranty and the hazardous location rating.

  • CAUTION : After the pump is installed and sewage has entered the basin there is Danger. Sewage water gives off methane and hydrogen sulfide gases, which are poisonous. Never enter a wet well unless the cover is open for a sufficient period of time to allow fresh air into the basin. It is recommended that a man in the basin have a harness on with a rope to the surface, so that he can be pulled out in case of asphyxiation. It is for this reason that Myers recommends using the rail lift-out system so that no service is required inside the basin.

  • Motor: Each motor is provided with heat sensor thermostats attached directly to the motor windings. The thermostats open if the motor windings see excessive heat and, in turn, open the motor contactor in the control panel, breaking the power to the pump. When the motor is stopped due to an overheat condition, it will not start until the motor has cooled and the heat sensor reset button is manually pushed on the front of the Myers control panel.

  • This circuitry is provided in the Myers control panel designs. The SX50/SX50H pumps are equipped with internal thermostats. The SX50/SX50H models are designed to meet Class B heat rise of 266°F (130°C).

  • Note: Failure to use proper circuitry and to connect the motor overheat protection in the control panel would negate all warranties and CSA Listings.

  • Motor Seal Failure Warning: The seal chamber is oil filled and provided with moisture sensing probes to detect water leakage through the lower shaft seal. The probes can also detect moisture present in the upper motor housing. The presence of water energizes a red seal leak warning light at the control panel. This is a warning light only, and does not stop the motor. It indicates a leak has occurred and the pump must be repaired. Normally, this indicates the outboard seal has leaked. Allowing the unit to operate too long after the warning could cause upper seal leakage along with motor failure.

  • The resistance across the moisture sensing (seal failure) probes should be checked after a seal leak warning light has lit. This can be done by disconnecting the red and orange control wires from the control panel, and measuring the resistance with an ohmmeter between the wires. The SX50/SX50H reading should be above 30,000 ohms. If the measured values are below those indicated above, the pump may have a lower seal failure and require service. On the Myers control panels the seal leak test switch tests the seal leak circuit continuity. When pushed the seal leak test bulb should light. If the test bulb does not light it means either the wiring circuitry to the seal leak probes have been broken or the bulb has burned out.

  • Note : Myers built control panels supply the correct circuitry for moisture and heat sensor connections. Failure to install the correct circuitry with proper connection would negate warranty and CSA Listing. See Figure 7.

  • Motor Power Cord, Control Cord and Cord

  • Cap Assembly: Each motor power cord has 4 conductors – white, black, red and green. For a single phase motor the black is connected to the common lead, the white is connected to the main lead, while the red is connected to the start circuitry, and the green is attached to a good ground. The  rotation of a single phase pump is set properly at the factory.
    For three phase motor, the black, white, and red conductors are power leads and the green is ground.
    Note : Rotation should be clockwise when observed from the top of the pump. This can be checked by noting which direction the pump torques upon initial starting. A properly rotating pump will torque counterclockwise upon start.

ALWAYS CHECK THREE PHASE PUMPS

FOR PROPER ROTATION BEFORE INSTALLING PUMPS.

The control cable has 5 conductors – black, white, red, orange and green. White and black connect to the heat sensor terminals in the control panels; red and orange connect to the seal failure terminals in the control panel; and the green connects to the ground in the control panel. The cord cap is epoxy potted. This allows the cord cap, with cords, to be removed from the motor. With this arrangement, the cords can be permanently installed in a sealed fitting in the sump. This should be an approved junction box for the specific hazardous locations. The control and power cables cannot be spliced!

Note: Each cable has a green ground wire and must be properly grounded per the National Electric Code and local codes.

  • Electrical Motor Controls : All electrical controls and motor starting equipment should be as specified in these instructions. Consult factory for any acceptable alternatives. For hazardous locations the controls and control panel must be installed outside the hazardous area. Only approved controls that are intrinsically safe may be used with these pumps.
  • Junction Box: If a junction box is used in a hazardous location, it must be an approved type with approved cord connectors. Wires from the junction box must pass through an approved seal connector for hazardous locations.
  • Level Sensing Control s: Intrinsically safe-type float controls are recommended for all applications and required for hazardous locations. An intrinsically safe control panel relay will limit the current and voltage to the level controls. A Myers control panel can be supplied with this type circuitry.

The float level controls maintain the basin sewage water level by controlling pump turn-on and turn-off levels.

  1. The lower turn-off control should be set so that the pump stops with the water covering the entire motor housing. Consult the factory for any settings below this point.
  2. The upper turn-on control should be set above the lower turn-off control. The exact height between the two controls is determined by the number of pump starts desired and the depth of the basin. A maximum of 10 starts per hour should not be exceeded.
  3. The override control is set at a specified height above the upper turn-on control.
  4. The alarm control is set about 6″ to 12″ above the override control.
  5. No control should be set above the inlet invert.
  • Electrical Connections: All electrical wiring must be in accordance with local code and only qualified electricians should make the installations. Complete wiring diagrams are included for use in making the installation. All wires should be checked for shorts to ground with an ohmmeter or megger after the connections are made. This is important, as one grounded wire can cause failure of the pump, control panel or personal injury.
  • Pump: The fluid end of the pump is field serviceable and can be disassembled in case of wear, damage, plugging or outboard seal failure. The following will describe the disassembly and reassembly process.
  • WARNING! Disconnect pump from power source before servicing or handling.

Disassembly

  1. With the pump located in a secure place, remove the bolts fastening the seal housing to the volute. The motor and impeller can now be removed as a unit.
  2. Lay the unit down on its side. If the lower seal is to be removed, it is recommended that the oil in the seal chamber be drained. This can be done by removing the lower seal chamber plug and draining the oil into a holding container.
  3. Using a proper wrench, the impeller retaining nut must be removed. This may require a piece of wood placed between the vanes to keep the impeller from rotating while removing the nut. Loctite® is used on this bolt and heating to 450–500°F may also be required to loosen. The impeller is mounted on a threaded shaft. To remove impeller, rotate impeller with one hand, while holding pump shaft with screwdriver.
  4. If the lower seal needs to be removed, first remove the compression spring that rides between the impeller and the seal assembly. Next take a pair of screwdrivers and remove the compression ring that surrounds the rubber bellows on the rotating portion of the seal assembly. Again using the screwdrivers, pry the remaining portion of the rotating seal assembly off the shaft. The ceramic stationary can be removed by placing a screwdriver between the rubber and the ceramic face, and then prying, working around the entire diameter. Note, these parts should be discarded and a new seal assembly installed.
  5. If the oil in the seal chamber was drained, examine the contents to determine if the upper seal has been damaged. Signs of grit or other abrasive material may indicate that the upper seal has also been damaged. Pressurizing the motor housing assembly between 7 and 10 psi and observing any drop in pressure will indicate if the upper seal is functioning properly.

Note : Upper seal repairs must be done at a Myers authorized service center or at the Myers factory. Any unauthorized field repair voids warranty and the CSA listing.

Reassembly

  1. 1. Remove the ceramic portion of the new seal from the package. Brush new dielectric oil around the rubber portion of the stationary assembly and into the pocket in the seal housing. Note, keep the oil off the seal face. Without scratching the seal face, press the ceramic stationary portion into the seal housing. A piece of PVC pipe that fits onto the face of the seal works well for installation. With clean cloth, lightly wipe the face of the seal surface to make sure it is dirt free. Remove the rotating portion of the seal from the package and lubricate the inside diameter of the rubber bellows and the outside diameter of the shaft. Place the seal over the shaft. Evenly press on the body of the rotational assembly and slide it down the shaft until the seal faces meet. A PVC pipe with the inside diameter slightly larger than the shaft diameter can work well to press the rotational assembly into position. Once the seal assembly is in position, place the spring over the register on the rotational portion of the seal.
  2. Thread the impeller onto the shaft, making sure that the seal spring is registered properly onto the back side of the impeller. Place the proper Loctite fluid on the impeller retaining nut. Tighten nut on shaft.
  3. Fill the seal chamber with new dielectric oil. An air gap of 10–15% volume must be left for the expansion of the oil when it is at operating temperature.
  4. The motor and impeller assembly can be installed into the volute, making sure that the units are aligned properly. Install the volute retaining bolts and tighten.
  5. Air tends to trap in the pump case when water rises in the sump or when the pump is lowered into the water after service. To vent off this air a small hole is drilled into the volute casting. Be sure this vent hole is clean after any service work on pump. Air venting is not a problem after initial start.

DIMENSIONS

SX50 DIMENSIONS

  • [Dimensions in mm]Myers-SX50-Sump-Pumps-fig-1

SX50H DIMENSIONS

  • [Dimensions in mm]
  • Myers-SX50-Sump-Pumps-fig-2

PARTS

SX50 PUMP PARTSMyers-SX50-Sump-Pumps-fig-3

  • SX50H PUMP PARTS

Myers-SX50-Sump-Pumps-fig-4

SX50/SX50H PARTS LIST

Ref. Description Qty. SX50 SX50H
1 CAP, CORD 1 22407C602 22407C602
2 CONNECTOR 7 12762A001 12762A001
3 TUBE, PLASTIC x 1-1/4″ LG. 2 10649A102 10649A102
4 SCREW, CAP 5/16 x 1-1/4″ LG. 8 19100A012 19100A012
5 O-RING, 4-1/2″ x 4-1/4″ x 1/8″ 1 05876A122 05876A122
6 CAP, UPPER BEARING 1 21570B100X 21570B100X
7 O-RING, 4-7/8″ x 4-5/8″ x 1/8″ 1 05876A123 05876A123
8 PLUG, PIPE 1/4″ NPT 2 05022A054 05022A054
9 SCREW, MACH. #10 x 1/2″ LG. 1 05434A034 05434A034
10 WASHER, LOCK 1 06107A015 06107A015
11 SCREW, MACH. 5/16 x 1″ LG. (SX50) 2 07597A017
11 SCREW, MACH. 5/15 x 1″ LG. (SX50H) 6   07597A017
12 HOUSING W/STATOR (1Ø) 1 21571D150K 21571D150K
HOUSING W/STATOR (3Ø) 230/460V 1 21571D152K 21571D152K
HOUSING, MOTOR   21571D100X 21571D100X
STATOR ONLY (1Ø)   21656C103 21656C103
STATOR ONLY (3Ø) 230/460V 1 21656C106 21656C106
13 OIL, TRANSFORMER (1 GAL. CAN) 1.06 gal. 11009A008K 11009A008K
14 WASHER, SPRING 2 19331A005 19331A005
15 BEARING, BALL (UPPER) 1 08565A013 08565A013
16 RING, RETAINING 1 11816A006 11816A006
17 ROTOR W/SHAFT (1Ø) 1 26859C101X 26859C101X
ROTOR W/SHAFT (3Ø) 1 26859C104X 26859C104X
18 BEARING, BALL (LOWER) 1 08565A018 08565A018
19 HOUSING, UPPER SEAL 1 21574D100X 21574D100X
20 SEAL, SHAFT 2 21576A010 21576A010
21 RING, RETAINING 1 12558A006 12558A006
22 ELECTRODE W/RESISTOR 1 22578A003 22578A003
23 O-RING, 6-1/8″ x 5-7/8″ x 1/8″ 2 05876A125 05876A125
24 FERRULE, RUBBER 1 22579A000 22579A000
25 PLUG, SPECIAL 1 21577A000 21577A000
26 HOUSING, LOWER SEAL 1 21578C110X 21578C115X
27 SCREW, CAP 5/16 x 1″ LG. 4 06106A008 —–
28 CASE, VOLUTE 1 21612D000 26226D012
29 SCREW, CAP 1/4 x 1″ LG. 3 19099A012 19099A012
30 IMPELLER, RECESSED 1 21663C020 21663C010
31 NUT, JAM 1 19109A070 19109A070
32 SCREW, SET 2 05013A027 05013A027

MOTOR ELECTRICAL DATA

SX50/SX50H

Available Models Motor Electrical Data

Standard

| ****

HP

| ****

Volts

| ****

Phase

| ****

Hertz

| ****

Start Amps

| ****

Run Amps

| ****

Service Factor Amps

| ****

NEC Code Letter

| ****

Service Factor

SX50-21| ½| 230| 1| 60| 12.5| 4.9| 5.9| H| 1.2
SX50H-21| ½| 230| 1| 60| 12.5| 4.9| 5.9| H| 1.2
SX50-23| ½| 230| 3| 60| 10.8| 3.2| 4.0| G| 1.25
SX50H-23| ½| 230| 3| 60| 10.8| 3.2| 4.0| G| 1.25
SX50-43| ½| 460| 3| 60| 5.4| 1.6| 2.0| G| 1.25
SX50H-43| ½| 460| 3| 60| 5.4| 1.6| 2.0| G| 1.25

WIRING DIAGRAMS

Myers-SX50-Sump-Pumps-fig-5

NOTE: All components shown must be approved for hazardous locations.

WIRING SCHEMATIC FOR 230V, 1Ø SIMPLEX SYSTEMMyers-SX50-Sump-Pumps-
fig-6Myers-SX50-Sump-Pumps-fig-7

WIRING DIAGRAM 230V, 1ØMyers-SX50-Sump-Pumps-fig-8

WIRING SCHEMATIC FOR 230V, 3Ø DUPLEX SYSTEMMyers-SX50-Sump-Pumps-
fig-9

NOTES:

  1. Level switches must be rated a minimum of 2 amps @ 120V.
  2. Torque all white field wiring terminals to 8 in. lbs.
  3. Field wiring must be 60°C copper wire minimum.
  4. ———- = items not supplied in the panel.

WIRING SCHEMATIC FOR 230V, 3Ø SIMPLEX SYSTEMMyers-SX50-Sump-Pumps-
fig-10 Myers-SX50-Sump-Pumps-fig-11

NOTES:

  1. Level switches must be rated a minimum of 2 amps @ 120V.
  2. Torque all white field wiring terminals to 8 in. lbs.
  3. Field wiring must be 60°C copper wire minimum.
  4. ———- = items not supplied in panel.

WIRING SCHEMATIC FOR 460V, 3Ø SIMPLEX SYSTEMMyers-SX50-Sump-Pumps-
fig-12 Myers-SX50-Sump-Pumps-fig-13

NOTES:

  1. Level switches must be rated a minimum of 2 amps @ 120V.
  2. Torque all white field wiring terminals to 8 in. lbs.
  3. Field wiring must be 60°C copper wire minimum.
  4. ———- = items not supplied in panel.

WIRING SCHEMATIC FOR 460V, 3Ø DUPLEX SYSTEMMyers-SX50-Sump-Pumps-
fig-14

NOTES:

  1. Level switches must be rated a minimum of 2 amps @ 120V.
  2. Torque all white field wiring terminals to 8 in. lbs.
  3. Field wiring must be 60°C copper wire minimum.
  4. ———- = items not supplied in panel.

CHECKLIST IF PUMP DOES NOT OPERATE PROPERLY

  • Checking for Moisture in Motor: Use an ohmmeter or a megger and set on highest scale. Readings on the large power cord between any of the conductors red, black or white to the green conductor or to the motor housing should be greater than 1,000,000 ohms (megohm). A motor will probably run with a lower reading, but if the pump is out of service and the value of the reading is below 1,000,000 ohms (1 megohm), the motor housing and stator should be removed and baked in a drying oven at 220°F. This service work should be done only at an authorized service station. Note, readings should be taken with line leads disconnected from the control panel.
  • Resistance of Windings: Every motor winding has a fixed resistance. The windings must check close to the values given in the tables to operate properly. See the motor electrical data chart (Figure 4). Use an ohmmeter and set to the one ohm scale. Read the resistance with the motor leads disconnected from the pump control panel.

CONDITION/ PROBABLE CAUSE

  • Red light comes on at control box.
    • This indicates some water has leaked past the lower seal and has entered the seal chamber and made contact with the electrode probe. Pump must be removed for replacement of lower seal. This preventive repair will save an expensive motor.
  • Overload trips at control box and alarm buzzer or flashing red light comes on due to high water level in basin.
    1. Push in on red reset button to reset overload. If overload trips again after short run, pump has some damage and must be removed from basin for checking.
    2. Trouble may be from clogged impeller causing motor to overload or could be from failed motor.
    3. Trouble may be from faulty component in control box. Always check control box before removing pump.
  • Yellow run light stays on continuously.
    1. Indicates H-O-A switch may be in the Hand position.
    2. Level control switch may have failed causing pump to continue to operate when water is below lower control.
    3. Impeller may be partially clogged causing pump to operate at very reduced capacity.
    4. Gate valve or check valve may be clogged causing low pump flow.
    5. Pump may be air locked.
  • Circuit breaker trips.
    1. Reset breaker by pushing completely down on handle then back to On position. If breaker trips again in few seconds it indicates excessive load probably caused by a short in the motor or control box. Check out instructions given with control box before pulling pump.
    2. If this condition happens after an electrical storm, motor or control box may be damaged by lightning.
    3. A resistance reading of the motor with lead wires disconnected from the control box can determine if trouble is in motor or control box.
  • Pump is noisy and pump rate is low.
    1. The impeller may be partially clogged with some foreign objects causing noise and overload on the motor.
  • Grease and solids have accumulated around pump and will not pump out of basin.
    1. Lower control switch may be set too high.
    2. Run pump on Hand operation for several minutes with small amount of water running into basin to clean out solids and grease. This allows pump to break suction and surge which will break up the solids. If level switch is set properly this condition generally will not occur.
    3. Trash and grease may have accumulated around floats causing pump to operate erratically.

IMPORTANT – The pump should be thoroughly cleaned of trash and deposits before starting disassembly operations.
CAUTION – DISCONNECT ALL POWER AND CONTROL WIRES TO THE MOTOR AT THE CONTROL PANEL BEFORE STARTING DISASSEMBLY OPERATIONS. NEVER RELY ON OPENING CIRCUIT BREAKER ONLY.

WARRANTY

STANDARD LIMITED WARRANTY

Myers warrants its products against defects in material and workmanship for a period of 12 months from the date of shipment from Myers or 18 months from the manufacturing date, whichever occurs first – provided that such products are used in compliance with the requirements of the Myers catalog and technical manuals for use in pumping raw sewage, municipal wastewater or similar, abrasive free non-corrosive liquids. During the warranty period and subject to the conditions set forth, Myers, at its discretion, will repair or replace to the original user, the parts which prove defective in materials and workmanship. Myers reserves the right to change or improve its products or any portions thereof without being obligated to provide such a change or improvement for prior sold and/or shipped units. Start-up reports and electrical schematics may be required to support warranty claims. Warranty is effective only if Myers authorized control panels are used. All seal fail and heat sensing devices must be hooked up, functional and monitored or this warranty will be void. Myers will only cover the lower seal and labor thereof for all dual seal pumps. Under no circumstance will Myers be responsible for the cost of field labor, travel expenses, rented equipment, removal/reinstallation costs or freight expenses to and from the factory or an authorized Myers service facility.  This limited warranty will not apply: (a) to defects or malfunctions resulting from failure to properly install, operate ormaintain the unit in accordance with the printed instructions provided; (b) to failures resulting from abuse, accident or negligence; (c) to normal maintenance services and parts used in connection with such service; (d) to units which are not installed in accordance with applicable local codes, ordinances and good trade practices; (e) if the unit is moved from its original installation location; (f) if unit is used for purposes other than for what it is designed and manufactured; (g) to any unit which has been repaired or altered by anyone other than Myers or an authorized Myers service provider; (h) to any unit which has been repaired using non factory specified/OEM parts.

Warranty Exclusions: MYERS MAKES NO EXPRESS OR IMPLIED WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. MYERS SPECIFICALLY DISCLAIMS THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR ANY PARTICULAR PURPOSE.
Liability Limitation: IN NO EVENT SHALL MYERS BE LIABLE OR RESPONSIBLE FOR CONSEQUENTIAL, INCIDENTAL OR SPECIAL DAMAGES RESULTING FROM OR RELATED IN ANY MANNER TO ANY MYERS PRODUCT OR PARTS THEREOF. PERSONAL INJURY AND/OR PROPERTY DAMAGE MAY RESULT FROM IMPROPER INSTALLATION. MYERS DISCLAIMS ALL LIABILITY, INCLUDING LIABILITY UNDER THIS WARRANTY, FOR IMPROPER INSTALLATION. MYERS RECOMMENDS INSTALLATION BY PROFESSIONALS. Some states do not permit some or all of the above warranty limitations or the exclusion or limitation of incidental or consequential damages and therefore such limitations may not apply to you. No warranties or representations at any time made by any representatives of Myers shall vary or expand the provision hereof.

START-UP REPORT

  • Distributor__Order #: Installing Contractor: ____ Phone: _ Sales Contact: __ Phone: _ Customer & Location _____
  1. SYSTEM INFORMATION
    • A. Size of wet well: __ Manufacturer:_____
    • B. Discharge from bottom of basin: ___ Location:__
    • C. Inlet from bottom of basin:____ Location: __
    • D. Type of check valves: __
    • E. Type of piping ____
    • F. Does system have suction and discharge gauges? ___
    • G. Pressure reading? Suction Discharge ____
    • H. Liquid being pumped:____ Temperature: __ % of solid: __
    • I. Sketch or photograph of system attached? _____
    • J. Any additional comments on system: __ __
  2. ELECTRICAL INFORMATION
    • A. Control panel part #:__ Panel rated amps: Manufacturer ____ Voltage: __ Phase: _____
    • B. Heater size: _____
    • C. Location of panel to wet well: ____
    • D. Incoming line voltage: Actual? ____
    • E. Voltage to pumps ____ Actual? _____
    • F. Type of junction box: ___ Manufacturer:_
    • G. Are floats installed in wet well? ___
    • H. Are floats set to engineer’s spec? ____
    • I. Are floats wired for proper sequencing? ____
    • J. Any additional comments on electrical: ____ __
  3. PUMP INFORMATION
    • A. Type of pump:__ Serial # __
    • B. Voltage: Phase: RPM:__ Amps:
    • C. Impeller size: __ C.O.S. TDH:____ GPM: ___
    • D. Voltage supplied from panel:_ Actual?: ___
    • E. Actual amperage (all phases): amps amps _____amps
    • F. Have you checked pump rotation? ____
    • G. Any additional comments on pumps: __ __

Acknowledge that all information is accurate and proper procedures have been followed:

Customer Signature:__ Date ___ Start-up Technician:__ Date __
Send to: Warranty Department, 740 E. Ninth Street, Ashland, OH 44805,

We will make this a permanent part of our file on this order.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Myers User Manuals

Related Manuals