Acuity Brands LTHCPX2X44000LM CPX LED Flat Panel Light Fixture Instruction Manual
- June 9, 2024
- Acuity Brands
Table of Contents
CPX LED Flat Panel Light Fixture
Instruction Manual
LTHCPX2X44000LM CPX LED Flat Panel Light Fixture
*Model Number
MODELS:
CPX 1X4 XXXXLM XXK
CPX 2X2 XXXXLM XXK
CPX 2X4 XXXXLM XXK| MODELS:
CPX 1X4 XXXXLMHE XXK
CPX 2X2 XXXXLMHE XXK
CPX 2X4 XXXXLMHE XXK
---|---
5-YEAR LIMITED PRODUCT WARRANTY
Visit www.acuitybrands.com to view the terms
and conditions of your Acuity Brands Lighting, Inc. limited warranty. * SAVE THESE INSTRUCTIONS
Protect yourself. Before installing, read these instructions carefully and
save them for future reference.
Date Installed: ————-
IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION
-
To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards please read all warnings and instructions included with and on the fixture box and all fixture labels.
-
Before installing, servicing, or performing routine maintenance upon this equipment, follow these general precautions.
-
Installation and service of luminaires should be performed by a qualified licensed electrician.
-
Maintenance of the luminaires should be performed by person(s) familiar with the luminaires’ construction and operation and any hazards involved.
Regular fixture maintenance programs are recommended. -
It will occasionally be necessary to clean the outside of the refractor/lens.
Frequency of cleaning will depend on ambient dirt level and minimum light output which is acceptable to user. Refractor/lens should be washed in a solution of warm water and any mild, non-abrasive household detergent, rinsed with clean water and wiped dry. Should optical assembly become dirty on the inside, wipe refractor/lens and clean in above manner, replacing damaged gaskets as necessary. -
DO NOT INSTALL DAMAGED PRODUCT! This luminaire has been properly packed so that no parts should have been damaged during transit. Inspect to confirm. Any part damaged or broken during or after assembly should be replaced.
-
Recycle: For information on how to recycle LED electronic products, please visit www.epa.gov.
-
These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in connection with installation, operation, or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser’s or owner’s purposes, this matter should be referred to Acuity Brands Lighting, Inc.
WARNING RISK OF ELECTRIC SHOCK
- Disconnect or turn off power before installation or servicing.
- Verify that supply voltage is correct by comparing it with the luminaire label information.
- Make all electrical and grounded connections in accordance with the National Electrical Code (NEC) and any applicable local code requirements.
- All wiring connections should be capped with UL approved recognized wire connectors.
CAUTION RISK OF INJURY
- Wear gloves and safety glasses at all times when removing luminaire from carton, installing, servicing or performing maintenance.
- Avoid direct eye exposure to the light source while it is on.
WARNING RISK OF BURN
- Allow lamp/fixture to cool before handling. Do not touch enclosure or light source.
- Do not exceed maximum wattage marked on luminaire label.
- Follow all manufacturer’s warnings, recommendations and restrictions for: driver type, burning position, mounting locations/methods, replacement and recycling.
CAUTION RISK OF FIRE
- Keep combustible and other materials that can burn, away from lamp/lens.
- Do not operate in close proximity to persons, combustible materials or substances affected by heat or drying.
CAUTION: RISK OF PRODUCT DAMAGE
- Never connect components under load.
- Do not mount or support these fixtures in a manner that can cut the outer jacket or damage wire insulation.
- Unless individual product specifications deem otherwise: Never connect an LED product to dimmer packs, occupancy sensors, timing devices, or other related control devices. LED fixtures must be powered directly off a switched circuit.
- Unless individual product specifications deem otherwise: Do not restrict fixture ventilation. Allow for some volume of airspace around fixture. Avoid covering LED fixtures with insulation, foam, or other material that will prevent convection or conduction cooling.
- Unless individual product specifications deem otherwise: Do not exceed fixtures maximum ambient temperature.
- Only use fixture in its intended location.
- LED products are Polarity Sensitive. Ensure proper Polarity before installation.
- Electrostatic Discharge (ESD): ESD can damage LED fixtures. Personal grounding equipment must be worn during all installation or servicing of the unit.
- Do not touch individual electrical components as this can cause ESD, shorten lamp life, or alter performance.
- Some components inside the fixture may not be serviceable. In the unlikely event your unit may require service, stop using the unit immediately and contact an ABL representative for assistance.
- Always read the fixtures complete installation instructions prior to installation for any additional fixture specific warnings.
- Verify that power distribution system has proper grounding. Lack of proper earth ground can lead to fixture failure and may void warranty.
All luminaires that contain electronic devices that generate frequencies above
9kHz from any component within the luminaire comply with Part 15 of the FCC
Rules. Operation is subject to the following two conditions: (1) This device
may not cause harmful interference (2) This device must accept any
interference received, including interference that may cause undesired
operation.
Failure to follow any of these instructions could void product warranties.
For a complete listing of product Terms and Conditions, please visit
www.acuitybrands.com. Acuity Brands Lighting,
Inc. assumes no responsibility for claims arising out of improper or careless
installation or handling of its products.
ABL LED General Warnings, Form No. 503.203
© 2010 Acuity Brands Lighting, Inc. All rights reserved. 12/01/10
CPX/SPX LED IMPORTANT SAFETY INSTRUCTIONS
THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE
INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF
THE PRODUCT AND THE HAZARDS INVOLVED
Installation Instructions
**Caution: MAKE SURE LUMINAIRE IS MOUNTED TO A SECURE STRUCTURE. USE
APPROPRIATE MOUNTING HARDWARE TO INSTALL FIXTURE RATED FOR YOUR APPLICATION.
FAILURE TO MOUNT FIXTURE CORRECTLY COULD RESULT IN SERIOUS INJURY.
ABOVE CEILING ACCESS REQUIRED
KEEP THESE INSTALLATION INSTRUCTIONS / CONSERVEZ CES INSTRUCTIONS
D’INSTALLATION
If recess mounting:
-
Place the fixture in the appropriate T-Bar ceiling structure.
-
From above ceiling, bend the attached T-Bar clips over the T-Bar ceiling on all 4 corners to secure the fixture to the T-Bar ceiling as shown in Figure 1. For suspension mounting, refer to Figure 2, and instructions provided with aircraft cable accessory.
a. Refrain from bending the T-bar clips multiple times prior to installation to prevent damage. -
Using a screwdriver (not supplied), remove access plate as shown in Figures 3 & 4, with grid power OFF make electrical connections from supply and properly ground as local codes dictate (refer to Figure 5).
a. Green wire – Ground
b. White wire – Neutral line in
c. Black wire – Hot line in -
If the dimming leads (purple & pink (or gray)) aren’t being used, cap them off (if not already done). Dimming leads are for low voltage dimming only.
a. Purple wire – 0-10V (+) (can be capped off if not in use)
b. Pink (or gray) wire – 0-10V (-) (can be capped off if not in use) -
Reinstall access plate with screwdriver.
-
If fixture includes factory installed emergency battery that is not externally mounted, refer to Figure 10 for incoming supply connections and Figure 11 for incoming supply connections with dimming.
-
Refer to Figure 12 for the wiring diagram if the fixture is equipped with an externally mounted battery.
Note , that the whip not connected to anything is the test switch connection which should be marked at the base of the whip with “FLEX B” on the battery.
Note: For
208V & 240V, connect one hot lead to Black and the other hot lead to white.
(figure 5)
In the event of needing to add an emergency battery in the field, refer to the
below instructions. Kit numbers can be found in the accessories section of the
spec sheet.
- Disconnect or turn off power before installation or servicing.
- Remove screw holding the access plate. Figure 3
- Remove the 4 screws holding the driver cover onto the housing and take the driver cover off, as shown in Figure 5.
- Break knockout from access plate, run wires through the access plate opening, install conduit end on access plate and either snap in or place nut on conduit threads. Figure 6, 7 and 8.
- From the wires coming from the external emergency battery conduit, make all the correct electrical connections as shown in Figure 9.
- Install the external emergency battery in the supplied enclosure per instruction provided.
- Install the access plate back on driver cover.
- Reinstall the driver cover on housing.
- Make remaining electrical connections in accordance with local and state code with the grid power off.
- Test switch/pilot light must be mounted in an adjacent ceiling tile. It cannot be mounted to the fixture.
SAVE THESE INSTRUCTIONS
For any questions, please contact
1-800-705-7378
Contractor Resources
Check out helpful programs, tools, installation videos and
more ACUITY BRANDS LIGHTING,
INC.
ONE LITHONIA WAY, CONYERS, GA 30012
www.AcuityBrands.com
References
- Acuity Brands | Lighting, Controls, and Building Management Solutions
- U.S. Environmental Protection Agency | US EPA
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>