Acuity Brands ATB0 LED Cobra Heads Instruction Manual

June 3, 2024
Acuity Brands

LED IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL SAFETY INSTRUCTIONS!
SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION

ATB0 LED Cobra Heads

  • To reduce the risk of death, personal injury, or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards please read all warnings and instructions included with and on the fixture box and all fixture labels.

  • Before installing, servicing, or performing routine maintenance upon this equipment, follow these general precautions.

  • Installation and service of luminaires should be performed by a qualified licensed electrician.

  • Maintenance of the luminaires should be performed by person(s) familiar with the luminaires’ construction and operation and any hazards involved. Regular fixture maintenance programs are recommended.

  • It will occasionally be necessary to clean the outside of the refractor/lens. Frequency of cleaning will depend on ambient
    dirt level and minimum light output which is acceptable to user. Refractor/lens should be washed in a solution of warm water and any mild, non- abrasive household detergent, rinsed with clean water and wiped dry. Should optical assembly become dirty on the inside, wipe refractor/lens and clean in above manner, replacing damaged gaskets as necessary.

  • DO NOT INSTALL DAMAGED PRODUCT! This luminaire has been properly packed so that no parts should have been damaged during transit. Inspect to confirm. Any part damaged or broken during or after assembly should be replaced.

  • Recycle: For information on how to recycle LED electronic products, please visit www.epa.gov.

  • These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in connection with installation, operation, or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser’s or owner’s purposes, this matter should be referred to Acuity Brands Lighting, Inc.

WARNING
RISK OF ELECTRIC SHOCK

  • Disconnect or turn off power before installation or servicing.
  • Verify that supply voltage is correct by comparing it with the luminaire label information.
  • Make all electrical and grounded connections in accordance with the National Electrical Code (NEC) and any applicable local code requirements.
  • All wiring connections should be capped with UL approved recognized wire connectors.

CAUTION
RISK OF INJURY

  • Wear gloves and safety glasses at all times when removing luminaire from carton, installing, servicing or performing maintenance.
  • Avoid direct eye exposure to the light source while it is on.

WARNING
RISK OF BURN

  • Allow lamp/fixture to cool before handling. Do not touch enclosure or light source.
  • Do not exceed maximum wattage marked on luminaire label.
  • Follow all manufacturer’s warnings, recommendations, and restrictions for: driver type, burning position, mounting locations/methods,  replacement, and recycling.

CAUTION
RISK OF FIRE

  • Keep combustible and other materials that can burn, away from lamp/lens.
  • Do not operate in close proximity to persons, combustible materials or substances affected by heat or drying.

CAUTION: RISK OF PRODUCT DAMAGE

  • Never connect components under load.
  • Do not mount or support these fixtures in a manner that can cut the outer jacket or damage wire insulation.
  • Unless individual product specifications deem otherwise: Never connect an LED product directly to a dimmer pack, occupancy sensors, timing devices, or other related control devices. LED fixtures must be powered directly off a switched circuit.
  • Unless individual product specifications deem otherwise: Do not restrict fixture ventilation. Allow for some volume of airspace around fixture. Avoid covering LED fixtures with insulation, foam, or other material that will prevent convection or conduction cooling.
  • Unless individual product specifications deem otherwise: Do not exceed fixtures maximum ambient temperature.
  • Only use fixture in its intended location.
  • LED products are Polarity Sensitive. Ensure proper Polarity before installation.
  • Electrostatic Discharge (ESD): ESD can damage LED fixtures. Personal grounding equipment must be worn during all installation or servicing of the unit.
  • Do not touch individual electrical components as this can cause ESD, shorten lamp life, or alter performance.
  • Some components inside the fixture may not be serviceable. In the unlikely event your unit may require service, stop using the unit immediately and contact an ABL representative for assistance.
  • Always read the fixtures complete installation instructions prior to installation for any additional fixture-specific warnings.

Please see product-specific installation instructions for additional warnings or any applicable FCC or other regulatory statements.
Failure to follow any of these instructions could void product warranties. For a complete listing of product Terms and Conditions, please visit www.acuitybrands.com.

Our Brands

Indoor/Outdoor
Lithonia Lighting Carandini
Holophane RELOC| Indoor Lighting
Gotham
Mark Architectural Lighting Peerless
Renaissance Lighting
Winona Lighting| Outdoor Lighting
American Electric Lighting
Antique Street Lamps
Hydrel Tersen| Controls
DARK TO LIGHT
Lighting Control & Design ROAM Sensor Switch Synergy
---|---|---|---

Acuity Brands Lighting, Inc. assumes no responsibility for claims arising out of improper or careless installation or handling of its products.
ABL LED General Warnings, Form No. 503.203
© 2013 Acuity Brands Lighting, Inc. All rights reserved. 6/12/13

ATB0 Light Trespass Shield
Installation and Maintenance Manual

INTRODUCTION

Product Description
The following Light Trespass Shield accessories are available on the ATB0:

Part Number Description
ATB0P20XR2/R5HSS ATB0 EXTERNAL HOUSE SIDE

SHIELD P20X R2 OR R5
ATB0P20XR3/R4HSS| ATB0 EXTERNAL HOUSE SIDE
SHIELD P20X R3 OR R4
ATB0P30XR2/R5HSS| ATB0 EXTERNAL HOUSE SIDE
SHIELD P30X R2 OR R5
ATB0P30XR3HSS| ATB0 EXTERNAL HOUSE SIDE
SHIELD P30X R3
ATB0P30XR4HSS| ATB0 EXTERNAL HOUSE SIDE
SHIELD P30X R4
ATB0P45XR2/R5HSS| ATB0 EXTERNAL HOUSE SIDE
SHIELD P45X R2 OR R5
ATB0P45XR3HSS| ATB0 EXTERNAL HOUSE SIDE
SHIELD P45X R3

The following ATB0 Light Trespass Shield are intended to limit the light directed on the opposing street side or directly behind the luminaire. These shields are not to be used with factory-installed House Side Shields (HS).
This component is designed for toolless installation utilizing two latches over the top of the luminaire.

INSTALLATION

Tools and Materials Required
None (Hand installable)

Light Trespass Shield:
Align text “SHIELD SIDE”, located on the underside of the Light Trespass Shield, with the side of the luminaire (front or rear) where light shielding is required. Place the two latches on the shield assembly over the top edges of the ATB0 Luminaire as shown in Figure 2. Press down on the latches individually to engage the Light Trespass Shield securely. ATB0 LTS30 is shown in Figure 2.

Contractor Resources:
Check out helpful programs, tools, installation videos, and more!

https://qrco.de/bby5LK

Figure 1 – Light Trespass Shield, Pre-Installation

Figure 3 –SHIELD SIDE Label

©2014 Acuity Lighting Group, Inc.
IN-330

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Acuity Brands User Manuals

Related Manuals