Eltako MSR12-UC Multifunction Sensor Relay Instruction Manual

August 13, 2024
Eltako

Eltako MSR12-UC Multifunction Sensor Relay

Specifications

  • Model: MSR12-UC
  • Part Number: 22 500 501-1
  • Type: Multifunction Sensor Relay
  • Installation: To be done by skilled electricians only

Product Usage Instructions

  • Installation:
    • Ensure that the power supply is switched off before installation.
    • Open the electrical panel where the sensor relay will be installed.
    • Connect the wires according to the wiring diagram provided in the manual.
    • Securely mount the sensor relay in place using appropriate fixtures.
    • Close the electrical panel and switch on the power supply to test the installation.
  • Operation:
    • After installation, configure the sensor relay settings as per your requirements using the control interface.
    • Test the sensor relay by activating different functions to ensure proper operation.
    • Monitor the sensor relay periodically for any issues or malfunctions.
  • Maintenance:
    • Regularly inspect the sensor relay for any signs of wear or damage.
    • Clean the sensor relay and its surroundings to prevent dust accumulation.
    • Replace any faulty components immediately to avoid operational issues.

FAQs

  • Q: Can I install the MSR12-UC sensor relay myself?
    • A: No, only skilled electricians should install this electrical equipment to prevent risks of fire or electric shock.

Installation Infomation

Only skilled electricians may install this electrical equipment otherwise there is the risk of fire or electric shock!

  • Temperature at mounting location: -20°C up to +50°C.
  • Storage temperature: -25°C up to +70°C.
  • Relative humidity: annual average value <75%.

Multifunction sensor relay for brightness, twilight, wind, rain, and frost, 5 OptoMOS semiconductor outputs 50mA/12..230V UC. Standby loss without weather data multi-sensor WMS only 0,5 watts.

  • DIN rail mounted device for mounting to DIN-EN 60715 TH35. 2 modules = 36mm wide, 58mm deep.
  • The Multifunction Sensor Relay MSR12 evaluates the signals from the weather data multi-sensor WMS once per second and sends appropriate control signals to the downstream EGS12Z or EGS12Z2 actuators depending on the setting of the rotary switch on the front.
  • The OptoMOS semiconductor outputs switch the voltage present on the universal voltage input terminal +B1. One weather data multi-sensor WMS can only be connected to a multifunction sensor relay MSR12.
  • However several MSR12 can be connected to a weather data multi-sensor WMS, e.g. for evaluating up to three directions with the light-sensor of the WMS.
  • Only one single MSR12 must provide the outer terminal resistance. It must be removed for any further MSR12.
  • Supply voltage 24V DC from the power unit WNT15-24VDC/24W. This power unit simultaneously supplies the weather data multi-sensor WMS connected to the terminals MS1, MS2, MSA, and MSB, including heating of the rain sensor surface.
  • After installation wait for the short automatic synchronization of approx. 1 minute. During this process, three LEDs flash in a slow sequence.

Function rotary switches

  • BA = Setting of the operation modes 1 to 10 from the adjacent chart. 2 delay times RD – for wind and twilight – each in connection with 5 brightness ranges for light and twilight. The LED behind the rotary switch indicates Frost at an outdoor temperature below 2°C, at this point output 6 is closed. This output opens again as soon as the temperature is above 3°C for 5 minutes.
  • O-S-W = If the weather data multi-sensor WMS is aligned towards the south, the weighting for light and twilight can be shifted towards the east or west. lf the WMS is mounted in a different direction, the desired point of the compass can be set using this rotary switch. An LED behind the rotary switch indicates Rain detection, at this point, output 4 is closed. Once the rain sensor surface dries out – assisted by a heating unit – contact 4 opens immediately. This is automatically followed by a 2-second pulse on output 2 if the sun signal is present at that moment.
  • m/s = This rotary switch is used to select the wind speed in meters per second at which the Wind signal is triggered. This closes output 5. This is indicated by the LED behind the rotary switch. The opening takes place after the delay time RD which has been set, during which the LED flashes. This is automatically followed by a 2-second pulse on output 2 if the sun signal is present at that moment.
  • DSR = In this position of the wind rotary switch the MSR12 operates like a twilight sensor relay. The twilight signal as described under Linux, is then continuously present at output 3 as long as the set twilight value is undershot. Output 3 opens with a delay of 5 minutes if the set twilight value is exceeded. Outputs 4 (Rain) and 6 (Frost) remain active as described there. Output 5 (Wind) likewise remains active, but the wind signal is triggered at 10m/s.
  • TEST = As long as ‘TEST’ remains switched on, each switchover from the ‘OFF’ position to the ‘TEST’ position activates the outputs 2 to 6 in ascending order. OFF = In the ‚OFF‘ position the MSR12 has no function.
  • Lux = This rotary switch is used to set the brightness at which the Sun signal is immediately triggered as a 2-second pulse on output 2. The LED behind the rotary switch indicates when the brightness value is exceeded.
  • Lux = This rotary switch is used for setting the brightness at which the 2-second Twilight signal is triggered at output 3 after the set delay time RD when the value is undershot. This is indicated by the LED behind the rotary switch. It flashes during the delay time. If the twilight switching threshold is set to the same level or higher than the sun switching threshold, then the sun switching threshold is raised internally above the twilight switching threshold.

Sensor function and open circuit monitoring:

  • The weather data multi-sensor WMS sends updated information to the MSR12 every second. If this signal is missing completely for 5 seconds, or if the individual signal from the wind sensor is missing for 24 hours, then an alarm is triggered:
  • The wind output 5 is closed for 2 seconds to protect any awnings or windows that may be connected here.
  • This pulse is repeated every hour. The wind LED flashes rapidly to signal the wind alarm. 3 LEDs flash rapidly at total signal failure. The alarm is turned off automatically when a signal is detected in.

Typical connection

Technical Data

  • OptoMOS 50mA/12..230V UC
  • Max./Min. temperature at mounting location +50°C/-20°C
  • Standby loss (active power) 0.5WU

Manuals and documents in further languages:

https://eltako.com/redirect/MSR12-UC.

CONTACT INFORMATION

  • Must be kept for later use! We recommend the housing for operating instructions GBA14.
  • ELTAKO GmbH D-70736 Fellbach
  • Technical Support English: +49 711 94350025
  • technical-support@eltako.de
  • eltako.com.
  • 03/2024 Subject to change without notice.