INKBIRD IDT-34c-B Wireless BBQ Thermometer User Manual
- June 12, 2024
- INKBIRD
Table of Contents
- IDT-34c-B Wireless BBQ Thermometer
- IMPORTANT NOTES/WARNINGS
- Overview
- Technical Specifications
- Product Diagram
- Key Definitions
- Battery Installation & Precautions
- Quickstart Guide
- APP Installation & Connection
- Cleaning and Maintanence
- Important Notes/Warnings
- Troubleshooting Guide
- FCC Requirement
- IC Warning
- Customer Service
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
IDT-34¢c-B WIRELESS BBQ
THERMOMETER
USER MANUAL
IDT-34c-B Wireless BBQ Thermometer
Please keep this manual properly for reference. You can also scan the QR code below to visit our official website for product usage videos. For any usage issues, please feel free to contact us at support@inkbird.com.
IMPORTANT NOTES/WARNINGS
- Keep children away to prevent them from being hurt by sharp probes.
- This product is not suitable for use in microwaves and pressure cookers. Do not expose this product to high temperatures, such as hanging/- placing it on a hot surface of a hearth, oven, or grill, or placing it inside the oven or grill,
- Do not expose the probes directly to fire or burning charcoal, or use them in an environment other than -22°F~572°F. Otherwise, the probe and probe cord will be damaged.
- Do not touch the probe or probe cord with your hands during/at the end of cooking. Wear heat-insulation gloves if necessary to avoid burns
- Do not immerse the probe in water, put it in the dishwasher, or use aggressive detergents to clean it. Rinse under running water and dry for storage,
- This thermometer is not waterproof. Be careful not use it in high-humidity environments such as bathrooms and gardens. Otherwise, it will be damaged.
- When it is necessary to replace the batteries, please be sure to choose high-quality alkaline batteries and safely dispose of the original batteries. When the power is insufficient, the temperature measured by the thermometer may be inaccurate or unusable.
« Reference Table for Minimum Internal Tempera- ture of Food Safety (USDA Database)
Food | Type | Internal Temperature (‘F) |
---|---|---|
Beefbison,veal, goat. and lamb | Steaks, roasts, chops | 145 Rest time: 3 |
minutes
Ground meat and sausage| 160
Cassoroles| Meat and meatless| 165
Chicken,turkey, y ‘ and other poultry| Alt whole bird, breasts, legs. thighs,
gibings. ground pouitry. lets, sausage, and stuffing inside poultry| 165
Eggs| Raw eggs| Cook until yolk and white are firm
Egg dishes (such as tritata quiche)
160|
Casseroles (containing meat and poultry)| 165
Hams| Raw ham| 145
Rost time: 3 minutes
Precooked ham (to reheat)| 165
Note: Reheat cooked hams packaged in USDA-inspected plants to 140°F
Leftovers| Amy type| 165
Pork| Steaks, roasts, chops| 145
Rest time: 3 minutes
Ground meat and sausage| 160
Rabbit and
venison| Wild or farm-raised| 160
Seafood| Fish (whole or filet) such as saimon.tunatiapia. collock
bass.cod,catfish, trout, etc| 145 or cook until flesh is no longer translcent
and secarales easily with a fork
Shrimp. lobster, crab, and scalops| Cook unti flesh is pearly or white, and
opaque
Clams, oysters, mussels| Cook unti shelis open during cooking
Overview
INKBIRD IDT-34c-B, a smart wireless BBQ thermometer, uses Bluetooth 5.1 to help you accurately measure the internal temperature of the food when grilling or cooking, reducing the waste of energy and food resources and preventing foodborne diseases. You can set the desired temperature and food doneness through the mobile application and remotely monitor the changes in food status through the phone. When the cooking is done, this smart thermometer will remind you that it is time to enjoy these delicious foods.
Technical Specifications
Model Number | 1DT-34c-B |
---|---|
Bluetooth Version | BLE 5.1 |
Bluetooth Connection Distance | 260ft/80m (without obstacles; for reference |
only)
Screen Type| HD Backlit LCD
Screen Size| 5736mm
Probe Number| 4
Probe Jack Size| p2.5mm; length 11mm
Probe Sensor Type| NTC
Temperature Measurement Accuracy| ±1r/±1.8°F
Temperature Measurement Range| -30-300°C /-22-572°F (Short-Time Measurememt)
20250t14’482°F (Continuous Monitoring)
Probe Cord Length| 1.2m/3.9ft
Temperature Calibration Range| ±7°C (±12.6’F)
Temperature Refreshing Time| <1s
Power Source| 2 AA Batteries
Dimension| 868338.5mm
Weight| 110g
Package Contents| Thermometer1 (IDT-34c-B) Probes
Probe Clamps
AA Batteries2
User Manual1
Product Diagram
- Screen Display Description
Log | Temperature is being logged. |
---|---|
Backlight is turned on. | |
Mute mode. | |
Alarm mode. | |
flashes | Bluetooth is pairing. |
remains on | Bluetooth is connected. |
disappears | Bluetooth connection is |
disconnected.
| Device battery level.
flashes| The device is low on power. Replace the batteries immediately.
°F/°C| Temperature unit.
H flashes| Remind you when the current temperature is detected to exceed the
preset temperature.
L flashes| Remind you when the current temperature is detected to be lower
than the preset temperature.
| Set a timer.
flashes| Alarm when the timer reaches.
Key Definitions
- Power ON/OFF: Press and hold the button for 3 seconds to turn on/off the device.
- When Bluetooth requests pairing, press the button to complete the pairing and connect.
- Cancel Alarm: When the temperature alarm is triggered, press the button tocancel the alarm.
- Low Battery: When the low battery prompt s triggered (the battery power is £10%), press the button to cancel the reminder.
- Force Restart (reset) : Remove the battery to reset the device.
Battery Installation & Precautions
- Open the battery compartment.
- Pay attention to the battery polarity and correctly install two new AA alkaline batteries.
- Cover the battery compartment and press and hold the power button for 3 seconds to turn on the thermometer.
- Precautions For Use
- Use two new alkaline batteries. Do not mix old and new, do not use rechargeable batteries, and do not use standard carbon-zinc batteries.
- Correctly install the batteries and turn on the device. After the probe is inserted into the probe jack, the part of the screen corresponding to the channel will display the current temperature.
- Insert the probe tip into the middle of the food to measure the internal temperature of the food.
- To perform parameter settings for the thermometer, select food menus, temperatures, and doneness levels, or monitor temperature changes, you should download and open the INKBIRD APP on your phone and connect it via Bluetooth.
- This device is suitable for continuous monitoring of food cooking progress. During cooking, please ensure that the probe is inserted nto the food and does not remove it The intemal temperature of the food will be displayed in the corresponding area of the thermometer screen.
Quickstart Guide
Before using your Bluetooth smart thermormeter IDT-34c8, please ensure that the device has two new A alkaline batteries installed and that you have read the Important Safety Information in this manual.
- When cleaning the stainless steel temperature probe included in the product packaging, please be careful not to immerse the probe or wire inwater or use aggressive cleaners as the probe may be damaged
- Prepare a smartphone running i0S 12 (or higher) or Android 7.1 (o highe), download the INKBIRD APR and complete the connection. (Please refer to section 7. APP Instalation & Connection in this Manual)
- Insert the cleaned probe into the probe channels of the thermometer in sequence, and the screen will isplay the real-ime temperatures correspondingtothe probes.
- Open the APP and set the parameters for the food to cook.
- Insert the probe into the center of the meat, avoiding nearby bones or cartilage. Be careful not to twist the probe wire, and keep the probe away from flames during cooking. You can use a probe clamp to secure the probe during cooking forstable and refiable measurements.
- If you will be using an oven, place the thermometer on a non-metallic and non-heated flat surface outside the oven and leave enough slack for the probe wire to prevent the probe from leaving the food during the closing of the oven door or from being connected loosely to the thermometer.
- When the internal temperature of the food reaches the set temperature, the thermometer will sound a sound alarm, and the APP will also send an alarm notification. To stop the alarm, you can press the button on the thermometer once or operate the APP to stop it. If you do not perform any operation, the alarm will not stop.
Note: After cooking, do not touch hot probes or wires immediately, and wear enough heat-nsulating gloves or tools if necessary to prevent burns.
APP Installation & Connection
7.1 INKBIRD APP
Search the INKBIRD App from Google Play or App Store to get it for free, or
you can scan the QR code left to download it directly.
https://inkbird.com/pages/download
NOTE
- Your i0S devices must be running i0S 12.0 or above to download the app smoothly.
- Your android devices must be running android 7.1 or above to download the app smoothly.
- APP Location Permission Requirement: We need to obtain your location information to discover and add nearby devices. INKBIRD promises to keep your location information strictly confidential. And your location information will only be used for the location function of the App and will not be collected, used, or disclosed to any third party. Your privacy is very important to us. We will abide by relevant laws and regulations and take reasonable security measures ‘o protect your information security.
7.2 Registration
Step1: Registering an account is necessary before using the INKBIRD app
for the first time.
Step2: Open the app, select your Country/Region, and a verification code
will be sent to you
Step3: Enter the verification code to confirm your identity, and the
registration is complete.
7.3 How to Connect
7.3.1 Open the INKBIRD app and Click “+” on the top right corner to add a
device. Then, follow the app instructions to complete the bluetooth
connection.
NOTES:
- Before starting the Bluetooth connection of the device, please ensure that your phone has been properly installed with the INKBIRD APP, enabled location, and allowed the INKBIRD APP to access location information.
- When using the Bluetooth connection, keep your phone as close as possible to the device. If the distance between the phone and the device is toolong or there are obstacles or blockers. the signal will weaken or even break off the connection.
- After successfully connecting the phone to the device, if you place the temperature sensor next to a metal table or object, the signal will weaken or even break off the connection. Please keep the device away from metal and keep the temperature sensor at least 1 m away from the ground.
- Please note that Bluetooth will always be on after the device is turned on, and only when the device is tumed off will the Bluetooth be tumned off.
Cleaning and Maintanence
- Pleaser store the thermometer and probes in a cool, dry place and keep children away.
- If you intend not to use this product for an extended time, we recommend removing the battery and keeping the battery compartment closed.
- After use, clean the probe with non-corrosive detergents, rinse under running water, and wipe it clean.
- If necessary, use a wet cloth to clean the thermometer and prevent water from entering the probe channel.
Important Notes/Warnings
- Do not immerse the thermometer or probe in water and do not wash it in adishwasher
- Do not use corrosive detergents to clean the probes.
- When in use, do not expose the thermometer to high temperatures. Do not place it on high-temperature appliances such as ovens or grills. That may cause product damage.
- Do not use or store this device in extreme weather or high-humidity environments. That may cause property loss or injury.
- This product is specially designed for grilling and cooking. Any other usage is not recommended.
Troubleshooting Guide
What can you do if the device is not working? Here are some possible reasons and relative solutions for reference. We hope they are helpful. For any further questions, please feel free to contact us at support@inkbird.com
Issues | Possible Solutions |
---|---|
Not Connected | 1) Make sure Bluetooth is enabled on your phone or tablet. |
- Check that your phone has location services enabled and the application has permission to use location.
- Position your phone or tablet as close as possible to the thermormeter, and we recommend keeping it away from metals or obstacles.
- Ensure the device is disconnected from other smartphones, and close the Bluetooth feature on these phones.
- Restart the device and open the applications again.
- Confirm that your phone or tablet s running an operating system version of i0S 12/Android 7.1 o higher.
- Remove the battery to reset the device.
- Close other Bluetooth devices within the connection range or disable their
Bluetooth feature.
Disconnect After
Connection| 1)Please position your phone as close as possible to the device. Ifthe distance between your phone and the thermometer i too long or there are many obstacles, the signal may weaken or break off the connection. - When using a Bluetooth connection, please do not place the – meter near
metal bjects and keep the thermometer at ‘east 1m away from the ground.
Otherwise, the signal may weaken or even break off the connection.
3)Please ensure that you have not disabled the location service feature on your phone or tablet or denied the location permission for the INKBIRD app during the operation of the thermometer
FCC Requirement
Changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment. This
device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions (1) this device may not cause harmful interference,
and (2) this device must accept any interference received, including
interference that may cause undesired operation.
Note:
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules, These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses, and can radiate
radio frequency energy, and if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio o
television reception, which can be determined by turing the equipment off and
on, the user is encouraged to try to correct the interference by one or more
of the following measures:
– Reorient or relocate the receiving antenna,
– Increase the separation between the equipment and receiver.
– Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected
~ Consult the dealer or an experienced radio/TV technician for help.
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment
IC Warning
This device contains licence-exempt transmitter(s)/receiver(s) that comply
with Innovation, Science and Economic Development Canada’s licence-exempt
RSS(s). Operation is subject to the following two conditions:
(1) This device may not cause interference.
(2)This device must accept any interference, including interference that may
cause undesired operation of the device.
The device meets the exemption from the routine evaluation limits in section
2.5 of RSS 102 andcompliance with RSS-102 RF exposure, users can obtain
Canadian information on RF exposure andcompliance
Customer Service
This item carries a 1-year warranty against defects in either components or workmanship. During this period, products that prove to be defective will, at the discretion of INKBIRD, be either repaired or replaced without charge. For any problems in use, please feel free to contact us at support@inkbird.com. We will do our best to help you
INKBIRD TECH.C.L.
support@inkbird.com
Factory address: 6th Floor, Building 713, Pengji Liantang
Industrial Area, NO.2 Pengxing Road, Luohu District,
Shenzhen, China
Office address: Room 1803, Guowei Building, NO.68
Guowei Road, Xianhu Community, Liantang, Luohu District,
Shenzhen, China