LANCOM IGS-3510XUP Systems GmbH Instruction Manual
- July 30, 2024
- LANCOM
Table of Contents
LANCOM IGS-3510XUP Systems GmbH
Product Specifications
- Model: LANCOM IGS-3510XUP
- Interfaces: TP Ethernet (10M/100M/1G), TP Ethernet (100M/1G/2.5G), SFP+ (1G/10G)
- Power Supply: Redundant power supply with 2 connectors (P1 and P2)
- Mounting: Rack-mountable
FAQ
Frequently Asked Questions
- Q: Can third-party accessories be used with this product?
- A: No, support service for third-party accessories is excluded. Please use compatible accessories recommended by the manufacturer.
Introduction
Before initial startup, please make sure to take notice of the information regarding the intended use in the enclosed installation guide!
Switch off the power supply before connecting or disconnecting modules or cables. The correct mains voltage is indicated on the product label. Check the voltage of your power source to ensure that you are using the correct voltage. Do not use a higher voltage than specified on the product label.
Please observe the following when setting up the device
- Keep all ventilation slots on the side of the device clear of obstruction
- Please note that support service for third-party accessories is excluded.
Mounting & Connecting
- TP Ethernet interfaces 10M / 100M / 1G
- Use suitable Ethernet cables to connect the interfaces 1 to 4 to further network devices.
- TP Ethernet interfaces 100M / 1G / 2.5G
- Use suitable Ethernet cables to connect the interfaces 5 to 8 to further network devices.
- SFP+ interfaces 1G / 10G
- Insert suitable LANCOM SFP modules into the SFP+ interfaces 9 to 10. Choose cables which are compatible with the SFP+ modules and connect them as described in the SFP+ module’s documentation.
- Ground terminal
- Reset button
- Device restart:
- Pressed for 2 ~ 7 seconds until system LED blinking green (port LEDs off)
- Configurations-Reset:
- Pressed for 7 ~ 12 seconds until system LED blinking green (port LEDs on)
- DIP switch for configuring the Rapid Ring behavior
- The default setting of the DIP switch is set to On / On (software control).
- In hardware control mode, all Rapid Ring software configurations via web, telnet and console are deactivated.
- Only Single Ring and Rapid Chain can be configured via DIP switches.
- The largest even/odd ports include both fiber optic and copper.
- With combo ports, either fiber optic or copper can be used as a ring connection.
- Configuration interface
- Connect the configuration interface to the serial interface of the device via which the switch is to be configured and / or monitored using the enclosed serial configuration cable.
- Digital inputs/outputs
- Power supply connectors
- Redundant power supply (2 connectors P1 and P2)
LED Description & Technical Details
A: TP Ethernet ports 10M / 100M / 1G PoE+
- Off Port inactive or deactivated
- Orange Link < 1 Gbps
- Orange, blinking Data transfer, link < 1 Gbps
- Green Link 1 Gbps
- Green, blinking Data transfer, link 1 Gbps
B: TP Ethernet ports 100M / 1G / 2.5G PoE++
- Off Port inactive or deactivated
- Orange Link < 1 Gbps
- Orange, blinking Data transfer, link < 1 Gbps
- Green Link 1 / 2,5 Gbps
- Green, blinking Data transfer, link 1 / 2,5 Gbps
C: SFP+ports 10G
- Off Port inactive or deactivated
- Green Link 10 Gbps
- Green, blinking Data transfer, link 10 Gbps
- Orange Link 1 Gbps
- Orange, blinking Data transfer, link 1 Gbps
D: SYS / ALM / P1 / P2 / RM / RC
- SYS off Device off
- SYS green Device ready
- ALM off Normal operating status
- ALM red An abnormal condition, such as temperature, voltage or DC power 1 / 2, has been detected
- P1 / P2 off No power supply via P1 / P2
- P1 / P2 green Power supply via P1 / P2
- RM off Deactivated
- RM green Ring Master detected
- RM orange Ring Member detected
- RC off Deactiviated
- RC green Rapid Chain detected
- (Aktive path)
- RC orange Rapid Chain detected
- (Backup path)
- RC orange, blinking No rapid chain switch found
Specifications
Hardware
- Power supply External power supply (not included)
- 44~57 VDC required for IEEE 802.3af (max. 15.4 W)
- 50~57 VDC required for IEEE 802.3at (max. 30 W)
- 50~57 VDC required for IEEE 802.3bt Type 3 (max. 60 W)
- 52~57 VDC required for IEEE 802.3bt Type 4 (max. 90 W)
- PoE acc. to IEEE 802.3af/at (PoE+) and IEEE 802.3bt (PoE++)
- Power consumption Max. 375 W (thereof 360 W PoE budget)
- Environment Temperature range -40 – 60 °C, humidity 10–90 %, non-condensing
- Housing Hardened metal housing for top-hat rail, 62 x 168 x 130 mm (W x H x D), Network connectors on the front
- Fan None; fanless design without rotating parts, high MTBF
Interfaces
- ETH: 4 TP Ethernet ports 10 / 100 / 1000 Mbps
- 4 TP Ethernet ports 10 / 100 / 2500 Mbps
- SFP: 2 SFP+ ports 10 Gbps
- 10 concurrent Ethernet ports in total
- CONSOLE 1 serial RJ45 configuration interface
Package Content
- Cable 1 serial configuration cable 1.5 m
More Information
Hereby, LANCOM Systems GmbH | Adenauerstrasse 20/B2 | D-52146 Wuerselen, declares that this device is in compliance with Directives 2014/30/EU, 2014/35/EU, 2011/65/EU, and Regulation (EC) No. 1907/2006. The full text of the EU Declaration of Conformity is available at the following Internet address: www.lancom-systems.com/doc
LANCOM, LANCOM Systems, LCOS, LANcommunity and Hyper Integration are registered trademarks. All other names or descriptions used may be trademarks or registered trademarks of their This document contains statements relating to future products and their attributes. LANCOM Systems reserves the right to change these without notice. No liability for technical errors and / or omissions.
Read User Manual Online (PDF format)