July 23, 2024
Avail

Avail NRCR Series CALIBRE Ergo 25mm Grab Rail

STOCK CODES

  • Ergo S (300mm) – NRCR2512
  • Ergo M (450mm) – NRCR2518
  • Ergo L (600mm) – NRCR2524
  • Ergo XL (900mm) – NRCR2530
  • Ergo XXL (1200mm) – NRCR2548

PRODUCT OVERVIEW

Avail-NRCR-Series-CALIBRE-Ergo-25mm-Grab-Rail-fig-
\(1\)

AVAIL QUALITY DESIGNS

  • Australian Owned and Designed
  • Sizes : 300 – 1200mm Lengths as standard, longer available by request Available in over 7 finishes including Living Brass, Chrome, Matt Black, Gunmetal, Brushed Nickel, Bronze, Gold Modular design, the rail to be mounted horizontally, vertically or at any angle and cut down to suit your bathroom
  • 150 kg capacity for all 25mm diameter calibre grab rails
  • Ergo 25mm diameter rails are suitable for heavy duty towel rails and smaller hands, in non-DDA bathrooms

INSTALLATION INSTRUCTIONS

  1. Locate wall studs, install into at least one stud. Place wall seal/mounting bracket on wall at correct height over centre of stud and mark hole positions on wall.

  2. Drill pilot holes into wall stud approximately 60mm deep to suit mounting screws (and wall plugs if required).
    Tip: 4mm hole for screws into timber or 10mm hole for wall plugs.

  3. Apply small amount of silicon to mounting bracket and wall in and around the screw holes.

  4. Install mounting brackets by screwing onto wall.Avail-NRCR-Series-CALIBRE-Ergo-25mm-Grab-Rail-fig- \(2\) Tip: Use appropriate mounting screws for the wall stud material, supplied screws are for timber wall studs.

  5. Slide rail tube into end bracket and push onto wall brackets.
    Tip: Rail length can be cut down to a smaller size, simply use at hegle wrin a fil hacksaw or pipe cutter then a grinder and reinsert into the end bracket.

  6. Tighten grub screws with the Allen key.

Tip: If rail rattles, loosen end bracket, twist slightly and tighten.

WARNING
These rails are designed to be mounted onto wall studs or masonry walls. Installation is recommended to be completed by qualified tradesperson who complies with the AS 1428.1- 2009 design for access and mobility standard. It is recommended rail location is determined by a qualified occupational therapist or trained professional to the AS 1428.1-2009 standard. Correct installation is required to ensure safe, long-term operation. Incorrect mounting can result in reduced capacity of the rail which can result in injury to user and damage to the wall.