VONROC VC507DC 20V Ash Vacuum Cleaner Instructions
- June 5, 2024
- VONROC
Table of Contents
VONROC VC507DC 20V Ash Vacuum Cleaner
SAFETY INSTRUCTIONS
Read the enclosed safety warnings, the additional safety warnings and the instructions. Failure to follow the safety warnings and instructions may result in electric shock, fire and/or serious injury. Save the safety warnings and the instructions for future reference.
The following symbols are used in the user manual or on the product:
- Read the user manual.
- Class II machine – Double insulation – You don’t need any earthed plug.
- Time-lag miniature fuse-link.
- Max temperature 45°C.
- For cold ash only! There is a risk of fire if the suction material exceeds a temperature of 40°C (104°F)!
- If the temperature of the material exceeds 40°C, there is a risk of fire.
- Do not throw the battery into fire.
- Do not throw the battery into the water.
- Separate collection for Li-ion battery.
- Do not dispose of the product in unsuitable containers.
- The product is in accordance with the applicable safety standards in the European directives.
SAFETY NOTES
THIS APPLIANCE CAN BE USED BY CHILDREN AGED FROM 8 YEARS AND ABOVE AND PERSONS
WITH REDUCED PHYSICAL, SENSORY OR MENTAL CAPABILITIES OR LACK OF EXPERIENCE
AND KNOWLEDGE IF THEY HAVE BEEN GIVEN SUPERVISION OR INSTRUCTION CONCERNING
THE USE OF THE APPLIANCE IN A SAFE WAY AND UNDERSTAND THE HAZARDS INVOLVED.
CHILDREN SHALL NOT PLAY WITH THE APPLIANCE. CLEANING AND USER MAINTENANCE
SHALL NOT BE MADE BY CHILDREN WITHOUT SUPERVISION.
- The ash cleaner should be properly assembled before use.
- Do not leave the machine running without supervision.
- Keep the nozzles and filters clean and functional to ensure that the machine works safe and has optimal performance.
- The user of the device is responsible for the safety of others while using it.
- The machine should only be used for its intended purposes.
- Only use the machine in areas that are dry and protected from bad weather. Do not use it outside when it is raining.
- Remove the battery pack from the vacuum cleaner before maintaining or cleaning, making any adjustments, changing accessories or placing the vacuum cleaner aside. This safety measure prevents accidental starting of the vacuum cleaner.
- Provide good ventilation at the working place.
- Have the machine repaired only through qualified specialists and only using original spare parts. This ensures that the safety of your vacuum cleaner is maintained.
- When the machine is not in use, store it securely.
- The storage place must be dry and lockable. This prevents the vacuum cleaner from being damaged when it is stored or being used by inexperienced people.
SAFETY WARNINGS SPECIFIC FOR VACUUMING ASHES
- The vacuum cleaner must not be used for the separation of hazardous substances.
- Do not vacuum up soot!
- Do not vacuum liquids.
- Only vacuum up the ash of permitted fuels!
- Do not vacuum up hot or burning objects or embers (e.g. cigarettes, charcoal, ashes, etc.). The temperature of the material must be below 40°C.
- Caution! If the temperature of the material exceeds 40°C, there is a risk of fire.
- Attention! Material that appears to have cooled down from the outside may still be very hot inside. This can be determined by combing the ashes with a metal tool before using the device. There will no longer be noticeable heat radiating from the cold ash.
- Hot ash particles may ignite again in the airflow.
- Temperatures exceeding 40°C may damage the vacuum cleaner, the hoses and the filter.
- Please make sure that the oven is cold before you vacuum clean ovens.
- Continuously check tubes, filter and vacuum cleaner for excessive temperatures during the vacuum cleaning.
- If you notice a temperature rise, switch off the vacuum cleaner immediately. Remove the filter and remove the material from the filter. Let the vacuum cleaner cool down under supervision.
- Completely empty the vacuum cleaner after vacuuming.
SAFETY WARNINGS SPECIFIC FOR BLOWING
- Direct air discharge at work area only. Never at people or animals.
- Risk of flying objects. Keep bystanders away from the work area.
- Always wear safety goggles before using the blowing function.
SAFETY WARNINGS FOR BATTERY
- Do not open the battery. The danger of shortcircuiting.
- Protect the battery against heat, e. g., against continuous intense sunlight, fire, water, and moisture. The danger of explosion.
- In case of damage and improper use of the battery, vapors may be emitted. Ventilate the area and seek medical help in case of complaints. The vapors can irritate the respiratory system.
- Use the battery only in conjunction with your Vonroc product. This measure alone protects the battery against dangerous overload.
- The battery can be damaged by pointed objects such as nails or screwdrivers or by force applied externally. An internal short circuit can occur and the battery can burn, smoke, explode or overheat.
SAFETY WARNINGS FOR CHARGER
Intended use
Charge only CD801AA and CD803AA type rechargeable Battery packs with the
charger. Other types of batteries may burst to cause personal injury and
damage.
- Do not recharge non-rechargeable batteries!
- During charging, batteries must be placed in a well-ventilated area!
MACHINE INFORMATION
Intended use
The vacuum cleaner is intended for domestic coldish vacuuming, for example,
cleaning a fireplace, barbeque, or another ash residue. The vacuum cleaner is
equipped with a blowing function. It can be used to blow dust and debris out
of garages or of patios and driveways. The device is not suitable for
commercial or industrial use.
TECHNICAL SPECIFICATIONS
This manual has been drawn up for different sets/article numbers. Check the corresponding article number in the below specifications table for the correct composition and contents of your set.
Model No. | Batteries included | Chargers included |
---|---|---|
VC507DC | – | – |
S_VC507DC | CD801AA | CD802AA |
S2_VC507DC | 2 x CD801AA | CD802AA |
S3_VC507DC | CD803AA | CD802AA |
Machine information
Voltage battery| 20V
Suction force| 10 kPA, 0.6m³/min
Container capacity| Approx. 12L
Tube diameter| Ø 35mm
Filter| HEPA
Recommended filter| VC808AA
Hose length| 1.0m
Weight (incl. accessories)| 2.4 kg
Model No.| CD801AA
---|---
Battery Type| Lithium-Ion
Voltage| 20V __
Capacity| 2.0 Ah
Recommended charger| CD802AA
Weight| 0.3 kg
Model No.| CD802AA
---|---
Charger input| 220-240V, 50Hz 0.4A
Charger output| 21V 2.5A
Charging time 2Ah battery| 60 minutes
Charging time 4Ah battery| 120 minutes
Recommended batteries| CD801AA, CD803AA
Weight| 0.36 kg
Model No.| CD803AA
---|---
Battery Type| Lithium-Ion
Voltage| 20V __
Capacity| 4.0 Ah
Recommended charger| CD802AA
Weight| 0.65 kg
Only use the following batteries VONROC VPOWER 20V battery platform. Using any other batteries could cause serious injury or damage the tool. CD801AA 20V, 2Ah Lithium-Ion
CD803AA 20V, 4Ah Lithium-Ion
The following charger of can is used to charge these batteries.
CD802AA Quick charger
The batteries of the VONROC VPOWER 20V battery platform are interchangeable
with all the VONROC VPOWER 20V battery platform tools.
DESCRIPTION
The numbers in the text refer to the diagrams.
- On/Off switch
- Carrying handle
- Vacuum port
- Blowing port
- Metal locking clamp
- Nozzles storage
- Container
- Top section
- Hose
- Aluminium round nozzle
- Aluminium crevice nozzle
- HEPA Filter
- Filter holder
- Battery
- Battery unlock button
- Battery LED indicators button
- Battery LED indicators
- Charger
- Charger LED indicators
ASSEMBLY
- Before any work on the power tool, remove the battery.
- The battery must be charged before first use.
Inserting the battery into the machine (Fig. B)
Ensure that the exterior of the battery is clean and dry before connecting to the charger or machine.
- Insert the battery (14) into the base of the machine as shown in Fig. B.
- Push the battery further forward until it clicks into place.
Removing the battery from the machine (Fig. B)
- Push the battery unlock button (15).
- Pull the battery out of the machine like shown in Fig. B.
Checking the battery charging status (Fig. C)
- To check the battery charge status, push the button (16) on the battery shortly.
- The battery has 3 lights indicating the charge level, the more lights that burn, the more charge the battery has left.
- When the lights are not burning it means the battery is empty and must be charged immediately.
Charging the battery with the charger (Fig. C)
- Take the battery (14) from the machine.
- Turn the battery (14) to an upside-down position and slide it onto the charger (18) as shown in Fig. C.
- Push the battery until it is fully pushed into the slot.
- Plug the charger plug into an electrical outlet and wait for a while. The LED indicators on the charger (19) will lighten up and show the charger status.
The charger has 2 LED indicators (19) which indicate the status of the charging process:
Red LED Status | Green LED status | Charger status |
---|---|---|
Off | Off | No power |
Off
| ****
On
| Standby mode:
– No battery is inserted or,
– Battery inserted but charging has
finished
On| Off| Battery charging in progress
- Fully charging the 2Ah battery may take up to 60 minutes.
- Fully charging the 4Ah battery may take up to 120 minutes.
After the battery is fully charged remove the charger plug from the outlet and remove the battery from the charger.
-
Slide the HEPA filter (12) over the filter holder(13) as shown in Fig. D.Clean the HEPA filter (12) regularly and after every heavy use to maintain the suction power.
-
Place the top section (8) on the container (7) as shown in Fig. E-1.
• Secure the metal locking clamps (5) of the container to the top section (8) as show in Fig. E- 2. -
Close the metal locking clamps (5) by pushing them downwards.
-
Connect the suction hose (9). For vacuuming (Fig. F): Connect the suction hose (9) to the vacuum port (3). For blowing (Fig. G): Connect the suction hose (9) to the blowing port (4).
OPERATION
Switching the machine on/off (Fig.A)
Do not vacuum without a Hepa filter!
- To switch on the vacuum cleaner, move the On/Off switch (1) forwards (direction ON).
- To switch off the vacuum cleaner, move the On/Off switch (1) backward (direction OFF).
Vacuuming (Fig. D, E-1, E-2, F)
Clean the HEPA filter (12) regularly and after every heavy use to maintain the suction power. Fine dust, such as dust from cement, soot and plaster are too fine to be used. Risk for getting into the motor and damaging it.
- Switch off (1) the machine and remove the battery (14).
- Unlock the metal locking clamps (5) and remove the top section (8).
- Before vacuuming, remove all dirt and debris from the container (7).
- Fit the filter. Carefully slide the HEPA filter (12) over the filter holder (13) as shown in Fig. D.
- Place the top section (8) on the container (7) as shown in Fig. E-1.
- Reattach the top section (8) again and lock the locking clamps (5). Fig E-2.
- Insert one end of the hose (9) into the vacuuming port (3).
- Place the battery (14).
- Press the power switch (1) into the “ ON/1”position to start your ash cleaner.
- The machine now is ready to use for vacuum cleaning.
- Press the power switch (1) into the “ OFF/0”position to switch off your ash cleaner.
Blow function (Fig. E-1, E-2, G)
- Operation without the use of a filter is recommended.
- Remove all dirt and debris from the container(7) before you use the blow function.
- Always wear safety goggles before using the blowing function.
- Risk of flying objects. Keep bystanders away from the work area.
Your ash cleaner is equipped with a blowing function. This function can be used to blow ash remains and dust out of corners and crevices which are difficult to access with vacuuming.
- Switch off (1) the machine and remove the battery (14).
- Unlock the locking clamp (5) and remove the top section (8).
- Before blowing, remove the filter (12) and remove all dirt and debris from the container (7).
- Reattach the top section (8) again and lock the locking clamps (5). Fig. E-1, E-2.
- Insert one end of the hose (9) into the blowing port (4) on top of machine. Fig. G.
- Place the battery (14).
- Press the power switch (1) into the “ ON/1”position to start your ash cleaner.
- The machine is now ready for blowing ashes and dust.
- Press the power switch (1) into the “ OFF/0”position to switch off your machine.
Finish operation (Fig. F)
- Turn off (1) the machine and remove the battery (14).
- Remove the top section (8) and empty the container (7).
- Clean the machine with a soft cloth.
- Disconnect hose, tube and container.
- Clean hose connectors, hose and tube after use, and keep them unblocked.
- Stow away the hose and accessory at the machine. Store the appliance in a dry room.
MAINTENANCE
Before cleaning and maintenance, always switch off the machine and remove the battery pack from the machine. Clean the machine casings regularly with a soft cloth, preferably after each use. Make sure that the ventilation openings are free of dust and dirt. Remove very persistent dirt using a soft cloth moistened with soapsuds. Do not use any solvents such as gasoline, alcohol, ammonia, etc. Chemicals such as these will damage the synthetic components.
Filters (Fig. B)
For optimal performance, it is recommended to regularly change the filter (12) depending on level of use. ****
- Carefully remove HEPA filter (12).
- Clean the dust on the HEPA filter (12) with a brush, and if necessary, wash it.
- Do not use cleaning products, solvents or sharp objects for any cleaning of the appliance, this includes the washable HEPA filter
- Allow filter to air dry before installing and using again.
- Reinstall the filter.
ENVIRONMENT
Faulty and/or discarded electrical or electronic apparatus have to be collected at the appropriate recycling locations.
Only EC countries
Do not dispose of power tools into domestic waste. According to the European
Guideline 2012/19/EC for Waste Electrical and Electronic Equipment and its
implementation into national right, power tools that are no longer usable must
be collected separately and disposed of in an environmentally friendly way.
WARRANTY
VONROC products are developed to the highest quality standards and are guaranteed free of defects in both materials and workmanship for the period lawfully stipulated starting from the date of original purchase. Should the product develop any failure during this period due to defective material and/or workmanship then contact VONROC directly.
The following circumstances are excluded from this guarantee:
- Repairs and or alterations have been made or attempted to the machine by unauthorized service centers;
- Normal wear and tear;
- The tool has been abused, misused or improperly maintained;
- Non-original spare parts have been used.
This constitutes the sole warranty made by the company either expressed or implied. There are no other warranties expressed or implied that extend beyond the face hereof, herein, including the implied warranties of merchantability and fitness for a particular purpose. In no event shall VONROC be liable for any incidental or consequential damages. The dealer’s remedies shall be limited to repair or replacement of nonconforming units or parts.
The product and the user manual are subject to change. Specifications can be changed without further notice.
DECLARATION OF CONFORMITY
VC507DC / S_VC507DC / S2_VC507DC / S3_VC507DC – ASH VACUUM CLEANER 20V
We declare under our sole responsibility that this product is in conformity with directive 2011/65/EU of the European Parliament and of the Council of 8 June on the restriction of the use of certain hazardous substances in electrical and electronic equipment is in conformity and accordance with the following standards and regulations:
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>