Profi-Pumpe SP02129-3 Lotus Blume Instruction Manual

July 20, 2024
profi-Pumpe

Profi-Pumpe SP02129-3 Lotus Blume Instruction Manual

Profi-Pumpe SP02129-3 Lotus Blume - front page

Technical changes, misprints and mistakes reserved! Newest information about our products can be found online at: http://www.profi-pumpe.de

SAFETY INSTRUCTION AND WARNINGS

Please read the user manual before using the device

Warning sign

INTRODUCTION

We would like to congratulate you on the purchase of our garden fountain. We appreciate your trust. That‘s why funtional security and operational safety stands by us on first place.

To prevent damage to persons or property, you should read this user manual carefully. Please observe all safety precautions and instructions for proper use of the pump. Failure to follow the instructions and safety precautions can result in injury or property damage.
Please keep this manual with the instructions and safety instructions carefully in order to at any time you can restore them. Please always download the latest version of the user manual ofwww.profi-pumpe.de under „downloads“. This shall always prevail.

IN GENERAL

The Garden fountains are high-quality fountain pump systems for outdoor or indoor use. The perfect eye-catcher.
****It‘s recommended NOT to conduct yourself technical modifications. First, it is not certain whether these changes are technically correct and, secondly, because no guarantee can be granted.
Transport damages are immediately to be reported to the package distributor and to us in written form. Failure to give timely notice to the shipping company, and are there- fore rejected your claims from the transport company, so we can not accept these claims as well. In your legal obligation to cooperate to minimize damage, we point out expressly herewith.

OPERATION

  • Unpack all components carefully. You should have received the following parts: 1pc Lotus leaf with white/orange flower / 1pc 12 hole daisy jet / 1pc 7 hole daisy jet / 1pc Fountain head adaptor / 1pc Pump outlet adaptor / Water flow valve / 1pc Pump with 5m cable / 1pc Solar panel / 1pc Solar panel bracket / 1pc Extension tube / 1pc Ground spike / 3pc screw
  • Remove the protective film from the solar panel (if any).
  • Position the solar panel so that it receives direct sunlight. The fountain can not work if the solar panel is shaded. Adjust the solar panel angle to maximise the amount of solar energy collected. Connect the pump on the panel (see illustration). Check whether the flow is fully open (or else promoted little or no water).

Profi-Pumpe SP02129-3 Lotus Blume - Position the solar
panel

Frost

Frost can cause damage to the pump. The pump must be removed and stored in a frost proof environment if the water is likely to freeze.

ASSEMBLY INSTRUCTION

Identify a suitable area in your pond for the lotus floating fountain. Put together the lotus with the pump.Profi-Pumpe SP02129-3 Lotus Blume -
ASSEMBLY INSTRUCTION
A water flow valve is included in the package. You can use it to adjust the fountain hight to fit your pond size, if necessary.
In order to keep the Lotus Fountain floating in A desired position in your pond and stop water loss from the pond, a net bag and wire pack are provided to keep the floating lotus in place.
Simply fill the net bag with small pepples and size the wire length to the correct depth of your pond.
Now the filled net bag will act as an Anchor to keep your lotus fountain in position and stop it from moving around.

Join the bracket, tube and ground spike together and then attach the solar panel to the bracket. Slide the bracket into the bracket slot in the backside of the solar panel.
A wall mounting bracket with 3pc wall mounting screws are incluted in pack. You can install the solar panel onto the wall/ fence (see diagram).

Twist pump plug slightly and pushing it into the pump socket. Make sure the sealing ring is fully in groove.
Now your solar pump is ready to use. It will begin to work after having received sufficient direct sunlight.

PERFORMANCE

After you have assembled the Lotus solar fountain and the solar panel, the pump starts to work after it has received enough direct sunlight and the battery is still sufficiently charged.

● Solar power pulse timing function
The product is designed to be on for approximately 2 seconds in pulse timing mode and off for 5 seconds as long as the pump is connected to the solar panel and the battery is sufficiently charged. The pump is shut down at dawn to save battery power. It restarts when the sun rises again the next morning.

The performance of the pump depends on the orientation of the solar panel to the sun and its intensity. The maximum output is achieved under optimal conditions in summer and partly in autumn and spring. A function in the shade or with cloudy sky cannot be guaranteed. For models with battery operation, the function depends on the state of charge of the batteries.

BATTERY INFORMATION

Batteries can age prematurely due to very short and frequent charging processes and many other operating influences. The batteries are therefore subject to a shortened warranty of 6 months as consumables and wearing parts.

If you notice that the battery appears to be less efficient, the battery must be recharged. To do this, leave the device in the sun for 1 day (pump must be connected). We recommend repeating this procedure occasionally to extend the battery life.

NOTE: The battery is supplied pre-charged. If, contrary to expectations, the charge level is not sufficient, the battery should be charged for at least 1 day (the pump must be connected to prevent damage to the battery from overloading).

Warnings on the rechargeable battery

Lithium-Ion cells and batteries may become hot, explode, or ignite, causing serious injury if not used for their intended purpose. The Li-Ion batteries have an extremely long service life and are therefore not intended for replacement. However, should you need to replace them, please be sure to observe the safety instructions listed below:

  • When inserting the batteries, be sure to observe the correct polarity.
  • Avoid that the positive and/or negative terminals and/or the poles of the batteries come into contact with each other or with metal. This can lead to a short circuit.
  • The batteries should not be disassembled or modified. The batteries contain safety and protective devices. Damage to the batteries may generate heat, explode or ignite.
  • Do not store the batteries in or near fire, stoves, or other objects that emit high temperatures. Do not expose the batteries to direct sunlight. Do not store the battery in a car in hot weather. The battery may explode or ignite at high temperatures.
  • Batteries should not be kept within the reach of children.
  • To avoid short circuits, cover the poles of the batteries with insulating tape before disposing of them.
  • Battery use should be discontinued immediately if unusual odors, a change in color, shape, or other abnormal circumstances occur.
  • Do not place the batteries in microwave ovens, high-pressure containers or on hotplates.
  • If liquid leaks from a battery and comes into contact with your eye, do not rub the eye, rinse well with water and seek medical attention immediately. If the eye is not treated immediately, the battery fluid may cause serious injury to the eye.

MAINTENANCE

  • Solar panel : The solar panel should only be cleaned with a clean, soft cloth and with a suitable, non-aggressive glass cleaning agent.
  • Pump : The pump should be cleaned from sediments and deposits at regular intervals, depending on the degree of contamination of the pond. To clean the pump impeller and filters, remove the plastic cover from the pump casing.
Storage
  • Before storing the pump, fully charge the battery as described.
  • To maintain the battery life, disconnect the pump plug and store all parts in a dry place.

RECOGNISING AND REPAIRING OF MISTAKES

Profi-Pumpe SP02129-3 Lotus Blume - RECOGNISING AND REPAIRING OF
MISTAKES

SECURITY TIPS

  • Obey absolutely valid regulations on the electrical security
  • Never run pump dry
  • Pumping inflammable, as well as all other aggressive liquids is prohibited
  • Pay attention to the medium max. 40°C
  • Any altering of the product itself or changing of the components is forbidden.
  • With longer unused times, clean the pump, wash it out with clear water, dry and store it at room temperature
  • Do not connect the pump to any AC voltage power directly, it’s ONLY for DC Voltage power.
  • Operate the pump in freshwater only (never above 50°C), especially keep it away from flammable liquids.
  • All solar panels are very sensitive, protect it before all against external mechanical influences (shock, vibration, etc.)
  • The pump may be used by children aged 8 years and above as well as persons with reduced physical, sensory or mental abilities or those who lack skills, experience and knowledge only if they are supervised. These aforementioned persons should only use the appliance while adhering to safe instructions and resulting dangers.
  • Cleaning and maintenance must not be carried out by children without supervision.

The manufacturer explains:

  • To take over no responsibility in the case of accidents or damages on the basis of carelessness or disregard to the instructions in this book.
  • to reject every responsibility for the damages which originate from the improper use of the pump.

GUARANTEE REGULATIONS

For all manufacturing and material defects, the statutory warranty applies. In these cases we take the replacement or repair of the device. Shipping costs shall be borne by our company, except as required by law. Please report the warranty on our service platform http://www.profi- pumpe.de/service.php. We will inform you how to proceed with case-related. Returns please sufficient postage. Unfortunately not prepaid returns can not be accepted because they are filtered out before delivery. Our service is provided in Germany.
The warranty does not cover:

  • Material wear (sealing rings, impeller wheels, impeller chambers)
  • Unjustified interventions or changes in the pump
  • Damages by self fault
  • Improper servicing and improper use
  • DRY RUNNING (Also partially!) of the pump

Moreover, we give no damage compensation for secondary damages!

NOTES ON PRODUCT LIABILITY

We point out, that we are only liable for damages under the Product Liability Act, which are caused by our units if no changes were made to the equipment. If repairs are carried out by our authorized service, we are only liable if original spare parts and accessories were used.

NOTES ON DISPOSAL

Electro devices of our company, labeled with the symbol of the crossed trash bin, are not permitted to be disposed in your household garbage. We are registered at the Ger- man registration department EAR under the WEEE-No. DE79535656 .
This symbol means, that you’re not allowed to treat this product as a regular household waste item – it has to be disposed at a recycling collection point of electrical devices. This is the best way to save and protect our earth.
THANK YOU FOR YOUR SUPPORT!

In connection with the sale of batteries or with the delivery of equipment containing rechargeable battery packs, the seller is obliged to draw your attention to the following: You are obliged to return used batteries as an end-user. You can return batteries after use to the seller or to the designated collection facilities, which are free of charge (eg: municipal collection points or in stores). You can return the batteries for disposal at no charge to the seller.

EU DECLARATION OF CONFORMITY

The undersigned, Amur S.à r.l., 36, Rue de la Gare, L-5540 Remich, certifies that the product named overleaf, namely LOTUS-BLUME-WEISS, LOTUS-BLUME- ORANGE as placed on the market, complies with the relevant provisions listed below, the relevant EU harmonised directives and the EU standard for safety. This declaration of conformity applies insofar as no modifications are made to the product. The sole responsibility for issuing this declaration of conformity lies with the manufacturer.

The sole authorised person to keep the technical documents:
Amur S.à r.l. – 36, Rue de la Gare – L-5540 Remich

Low Voltage Directive (2014/35/EU)

EC Electromagnetic compatibility directive (2014/30/EU)
The following harmonized standards:
EN 55014-1:2006
EN 55022:2006
EN 55014-2:1997+A1:2001

Signed for and on behalf of:
Amur S.à r.l.
Remich, 28.02.2024

i.V. Dipl. Phys. Peter Neumüller
Technical Manager

TECHNICAL DATA

Profi-Pumpe SP02129-3 Lotus Blume - TECHNICAL DATA

SPARE PARTS

Profi-Pumpe SP02129-3 Lotus Blume - SPARE PARTS

Imprint

Amur S.à r.l.
www.amur.lu
Email: info@amur.lu
Tel.: +49 611 9458777-0
Fax: +49 611 9458777-11

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

profi-Pumpe User Manuals